  1. Path: sparky!uunet!zaphod.mps.ohio-state.edu!sdd.hp.com!cs.utexas.edu!rutgers!fdurt1.fdu.edu!wisdom.bubble.org!jeff
  2. From: jeff@wisdom.bubble.org (Jeff Ross)
  3. Newsgroups: comp.dcom.servers
  4. Subject: Re: datability flow ctrl
  5. Message-ID: <1992Dec17.041459.20400@wisdom.bubble.org>
  6. Date: 17 Dec 92 04:14:59 GMT
  7. References: <1992Dec15.220810.14729@cuug.ab.ca>
  8. Distribution: na
  9. Organization: Wisdom's Pony Express
  10. Lines: 49
  11.  
  12. In article <1992Dec15.220810.14729@cuug.ab.ca> cappisk@cuug.ab.ca (Kevin Cappis 283-6333) writes:
  13. >
  14. >
  15. >
  16. >Hello out there,
  17. >
  18. >     First of all I hope this is the right group, from what I've read
  19. >I believe this is the right one. I have a term server that was built by 
  20. >DATABILITY but is using a different brand name (oem product). 
  21. >     
  22. >     Here is my problem. Everything seems to work just great, however I
  23. >have been experiencing problems with CTS flow control. When a large file
  24. >goes out the server port into the modem eventually the modem will drop CTS.
  25. >The server then stops sending data, but when the modem raise CTS the port
  26. >becomes locked up. The port status (sh po xx status) shows the port as
  27. >"xoffed". This seems obvious however a datascope shows that no xoff chars
  28. >are sent from modem.
  29.  
  30. a few items to check, first off you can type "monitor port XX status"
  31. and you will get a constantly updating screen of what's going on in terms
  32. of signals high and low.
  33.  
  34. in terms of "xoffed" it is a generic term just meaning that the terminal
  35. server is to stop sending data.
  36.  
  37. >
  38. >     The server is set for CTS flow conrtol enabled and the cabling appears
  39. >to be correct, as well as the modem parameters. (zyxcel 3242bis modems)
  40.  
  41. what are the parameters for the port?? i.e. "sho port xx"
  42.  
  43. >
  44. >     Has anybody got the same setup working okay, or the same problem?
  45. >If so reply to cappisk@sun.cuug.ab.ca
  46.  
  47. I used to run several high speed modems off a vcp-1000 (probably the same
  48. unit you have, on the 8 port line cards, no problems.
  49.  
  50. >
  51. >                                          Adios, Kevin Cappis
  52. >
  53.  
  54.             Jeff
  55.  
  56. -- 
  57.  