  1. Comments: Gated by NETNEWS@AUVM.AMERICAN.EDU
  2. Path: sparky!uunet!paladin.american.edu!auvm!NIU.BITNET!Y13SPF1
  3. Message-ID: <SAS-L%92121618471781@OHSTVMA.ACS.OHIO-STATE.EDU>
  4. Newsgroups: bit.listserv.sas-l
  5. Date:         Wed, 16 Dec 1992 17:47:00 CST
  6. Reply-To:     Sean Fahey <Y13SPF1@NIU.BITNET>
  7. Sender:       "SAS(r) Discussion" <SAS-L@UGA.BITNET>
  8. From:         Sean Fahey <Y13SPF1@NIU.BITNET>
  9. Subject:      Rlink and "remote=async2"
  10. Lines: 10
  11.  
  12. I  have  recently reconfigured the interrupts for my serial ports and
  13. can no  longer  use  "signon"  to  connect  via  com  2.   I'm  using
  14. "remote=async2" to access com 2 which is now configured to use IRQ 5.
  15. No  other  applications have any trouble using com 2 (Procom, Kermit,
  16. etc..) which is connected to our mainframe via a Micom network.  When
  17. I change the cables, set remote=async, and use com 1 everything works
  18. fine.   This  may be because the IRQ and address setting for com1 are
  19. the standard 3f8,4.  Since rlink always worked fine before,  is  this
  20. problem  due  to the nonstandard IRQ 5 setting?  If so, are there any
  21. fixes?