home *** CD-ROM | disk | FTP | other *** search
/ NetNews Usenet Archive 1992 #27 / NN_1992_27.iso / spool / vmsnet / pdp11 / 858 < prev    next >
Encoding:
Text File  |  1992-11-18  |  2.8 KB  |  69 lines

  1. Newsgroups: vmsnet.pdp-11
  2. Path: sparky!uunet!haven.umd.edu!darwin.sura.net!zaphod.mps.ohio-state.edu!caen!batcomputer!munnari.oz.au!uniwa!cujo!cc.curtin.edu.au!zrepachol
  3. From: zrepachol@cc.curtin.edu.au
  4. Subject: Re: 11/94 Upgrade problems....
  5. Message-ID: <1992Nov19.202849.1@cc.curtin.edu.au>
  6. Lines: 57
  7. Sender: news@cujo.curtin.edu.au (News Manager)
  8. Organization: Curtin University of Technology
  9. References: <1992Nov12.151415.21751@thijssen.nl>
  10. Date: Thu, 19 Nov 1992 11:28:49 GMT
  11.  
  12. In article <1992Nov12.151415.21751@thijssen.nl>, geveld@thijssen.nl (Ge v.d. Veldt) writes:
  13. > Hello,
  14. > We experienced 2 problems while upgrading a PDP11/84 to a PDP11/94.
  15. > The PDP 11/84 contains very old hardware such as:
  16. >         Emulex SC21 diskcontroller with M2322 Fujitsu disk
  17. >         RL11 diskcontroller
  18. >         Delua ethernet controller
  19. >         Emulex TC12 tapecontroller with M890 Cipher drive
  20. >         DL11-W asynchronous controller
  21. >         DZ11 asynchronous Multiplexer
  22. >         DT07 unibusswitch
  23. >         ICR11 I/O subsystem
  24. >         Fisher and Porter CCM communication controller
  25. > Problem 1:
  26. > The RSX11M-plus operating system crashes at random time intervals with the 
  27. > following console message:
  28. >         XXXXXXXXX Exec. parity error stop XXXXXXXXX
  29. > After that the CPU halts, no time to generate an errorlog entrie. The same
  30. > system has no problems when the CPU is a PDP11/84.
  31.  
  32. Have read the mail you sent, 4 ICRs!! The question that occurs first is Where
  33. did you get the M-Plus ICS/ICR driver? I assume you are using the DT07 as a
  34. manual switch between 2 CPUs.
  35.  
  36. > Problem 2
  37. > The PDP11/94 processor seem to have another power-up sequence compared with 
  38. > the PDP11/84. When the DT07 has selected  the PDP11/94 CPU for unibus exten-
  39. > sion the frontpanel halt/reset tockle switch will bring the CPU in a not 
  40. > accessable  state when manipulated. The only way to get out of that state 
  41. > (without powering down the system) is to deselect the unibusextension via the
  42. > DT07 frontpanel switches and restart the 11/94 again. This time the normal
  43. > powerup sequence will take place.
  44. >         WHO HAS  ANY  SUGGESTIONS FOR THESE PROBLEMS????
  45.  
  46. There was a simular problem with the 84 as I remember. This was fixed by an ECO
  47. to the CPU to increase the reset time or some such. Best refer this one to some-
  48. one in Utrecht I think. Good luck finding a Digit who knows what an 11 is!!
  49.  
  50. As to the UDA related problem I mentioned before, I think the NPG line was the
  51. main culprit. The fix was to replace a couple of the wire runs in the DKs with
  52. twisted pair. If you have access to the 11 fische library, its in there in the
  53. ECO listings. You will need to do the same fix to the DT07, ICS/ICR bachplanes
  54. and all the DD-11s if its not been done. Can you run the system without the
  55. ICS/ICR? The other errors hint that exec I-space is being corrupted, poss by
  56. erratic DMA.
  57.  
  58. ~Paul
  59.  
  60.