home *** CD-ROM | disk | FTP | other *** search
/ NetNews Usenet Archive 1992 #27 / NN_1992_27.iso / spool / comp / os / coherent / 5695 < prev    next >
Encoding:
Internet Message Format  |  1992-11-17  |  2.0 KB

  1. Path: sparky!uunet!charon.amdahl.com!pacbell.com!ames!sun-barr!sh.wide!wnoc-tyo-news!dclsic!nscgw!tatsumi
  2. From: tatsumi@elelab.nsc.co.jp (Tetsu Tatsumi)
  3. Newsgroups: comp.os.coherent
  4. Subject: Re: how to enlarge tty buffer?
  5. Message-ID: <tatsumi.flora100307@elelab.nsc.co.jp>
  6. Date: 18 Nov 92 05:00:42 GMT
  7. References: <tatsumi.flora100306@elelab.nsc.co.jp> <F17DuB1w165w@micromed.com>
  8. Sender: news@nscgw.elelab.nsc.co.jp
  9. Distribution: comp
  10. Organization: Computer Systems Lab., Electronics Research Labs., Nippon Steel
  11. Lines: 29
  12. Nntp-Posting-Host: flora.elelab.nsc.co.jp
  13. In-reply-to: system@micromed.com's message of 17 Nov 92 16:44:14 GMT
  14.  
  15. > tatsumi@elelab.nsc.co.jp (Tetsu Tatsumi) writes:
  16. > >      I am using Coherent 4.0 and I want to enlarge tty (or com/asy)
  17. > > buffers because they miss much characters at 9600bps or 19200bps
  18. > > on /dev/com1fl or /dev/asy**fl, /dev/asy**fr (I use 2 usual COM ports
  19. > > and Comtrol Hostess 550 multi-port serial card).  And what is worse,
  20. > > tty ports with flow control were sometimes choked up because both
  21. > > CS and RS were turned off.
  22.  
  23.      I found a mistake in /etc/ttys.  I made gettys run for
  24. /dev/com#fpl (polling ports) so they wasted CPU time.  I stopped
  25. gettys on polling ports, and now other ttys miss less characters
  26. (but still missing some).
  27.  
  28. In article <F17DuB1w165w@micromed.com> system@micromed.com (Duane Davis) writes:
  29.  
  30. > One of the techs at MWC told me it was best NOT to use the flow control
  31. > ports because they used software (XON/XOFF) flow control. It's better to
  32. > use the regular ports with hardware flow control enabled.
  33.  
  34.      But they sais that devices with flow control uses the CS/RS
  35. flow control in Coherent 4.0 manual.  And I checked the ttys with
  36. flow control sometimes turn on/off RS with an RS232-checker...
  37. (a difference between 2 versions?).
  38.  
  39.      /*-----------------------------*------------------------------------/
  40.     /   tatsumi@elelab.nsc.co.jp   /   Sagamihara Kanagawa 229, JAPAN   /
  41.    /------------------------------*-----------------------------------*/
  42.  
  43. P.S.  I received a mail from MWC about this question.
  44.