home *** CD-ROM | disk | FTP | other *** search
/ NetNews Usenet Archive 1992 #27 / NN_1992_27.iso / spool / comp / dcom / isdn / 860 < prev    next >
Encoding:
Text File  |  1992-11-20  |  2.4 KB  |  78 lines

  1. Newsgroups: comp.dcom.isdn
  2. Path: sparky!uunet!psinntp!wrldlnk!usenet
  3. From: "Bob Larribeau" <p00136@psilink.com>
  4. Subject: re: COMBINET PROBLEM
  5. In-Reply-To: <dem.721679452@nhmpw2.fnal.gov>
  6. Message-ID: <2931275823.15.p00136@psilink.com>
  7. Sender: usenet@worldlink.com
  8. Nntp-Posting-Host: 127.0.0.1
  9. Organization: Consultant
  10. Date: Thu, 19 Nov 1992 19:20:53 GMT
  11. X-Mailer: PSILink-DOS (3.3)
  12. Lines: 64
  13.  
  14. The following is a message that I am posting at the request of Combinet 
  15. in response tothe message from David E. Martin.  Im not associated with 
  16. Combinet.  If you have any questions, please contact Combinet directly 
  17. at (408)522-9020.
  18.  
  19.         Bob Larribeau
  20.         San Francisco
  21.  
  22.  
  23.  
  24.  
  25. >If your network has more than 1500 ethernet devices, you are
  26. >susceptible to this problem. A quick fix is to set the aging time
  27. >to a small value (like 60 sec).  Combinet is working on a fix. 
  28. >  
  29. >   
  30. >David E. Martin
  31. >National HEPnet Management                      ||    Phone: +1 708 840-8275
  32. >Fermi National Accelerator Laboratory           ||    FAX: +1 708 840-8463
  33. >P.O. Box 500, MS 368; Batavia, IL 60510  USA   /  \   E-Mail: dem@hep.net
  34. >
  35.  
  36.  
  37. To Combinet Interchange Users:
  38.  
  39. This note applies to users of the Combinet INTERCHANGE(tm)
  40. Bridge, Software version 2.11 or below:
  41.  
  42. For large networks (over 1500 Ethernet addresses), it is
  43. important that the Combinet Interchange be configured as
  44. described below.
  45.  
  46. If a small remote workgroup (less than 250 Ethernet addresses) is
  47. being bridged to an enterprise LAN, the two Interchanges should
  48. be configured as follows:
  49.  
  50.      1) The Interchange which is connected to the enterprise LAN
  51.      should be set as follows:
  52.  
  53.           SEt MOde ONly
  54.  
  55.      2) The remote LAN Interchange should be set as follows:
  56.  
  57.           SEt MOde ANy
  58.           SEt AGe 1200
  59.  
  60. If two large networks are being bridged, both Interchange units
  61. should be set up as follows:
  62.  
  63.           SEt MOde ANy
  64.           SEt AGe 1200*
  65.  
  66. * The aging time parameter (1200 in the example) is network
  67. dependent.  The aging time should be set such that the address
  68. table will not exceed 1500 addresses.
  69.  
  70. There is a new release of Interchange software (2.15) which
  71. ensures correct operation of the units independent of
  72. configuration.  This is currently available by calling Combinet
  73. technical support.
  74.  
  75. Note:  The address aging feature is not available in software
  76. versions below 2.02.  In this case, it is recommended that units
  77. be upgraded to release 2.15.
  78.