home *** CD-ROM | disk | FTP | other *** search
- Comments: Gated by NETNEWS@AUVM.AMERICAN.EDU
- Path: sparky!uunet!paladin.american.edu!auvm!UOKMVSA.BITNET!UA4431
- Message-ID: <NOTIS-L%92112010032497@VM.TCS.TULANE.EDU>
- Newsgroups: bit.listserv.notis-l
- Date: Fri, 20 Nov 1992 10:02:00 CST
- Sender: NOTIS discussion group list <NOTIS-L@TCSVM.BITNET>
- From: "Zia Partovi 325-3181 (405)" <UA4431@UOKMVSA.BITNET>
- Subject: Re: ABII MDAS Initial load
- Lines: 28
-
- We had this problem. To locate records with the duplicate control number I wro
- te a program to match records for their control numbers. Then, using DITTO (a
- VSE utility) I changed the control number of one of the records. This has work
- ed fine for us.
-
- Zia Partovi - Tech 1
- University of Oklahoma
- ua4431@uokmvsa
- ------------------------------TEXT-OF-YOUR-MAIL--------------------------------
-
- > We are trying to do an initial load of ABII. We run MPC650B to
- > create the Bib file, but are confused as to why there are
- > delete records created???? Any way, we cannot create an XREF
- > file to process update tapes or apply the delete records because
- > we get a "U066" in MPC680 trying to create the XREF file (which
- > is required to apply updates or deletes). We have been told by
- > NOTIS that U066 means we have duplicates.
- >
- > Has anyone else had this problem or any ideas on how to get
- > around this problem??? We are just about out of ideas and
- > would appreciate ANY help or suggestions.
- >
- > Thanks in advance,
- >
- > Russ Dinsmore - Tech 1
- > University of Virginia
- > rd2h@virginia.edu
- > (804) 924-1052
-