- Newsgroups: vmsnet.internals
- Subject: RE: Obtaining Decnet line counters from HLL
- Message-ID: <23JUL92.12285999@jevex.waisman.wisc.edu>
- Date: 23 Jul 92 17:28:59 GMT
- References: <22JUL92.17550567@jevex.waisman.wisc.edu>
- Sender: news@pslu1.psl.wisc.edu (USENET News System)
- Organization: Waisman Center, University of Wisconsin-Madison
- Lines: 19
-
- In a previous article, I wrote:
- >Does anyone have an example of obtaining the values for Decnet (ethernet) line
- >counters from a HLL program? I'm particularly interested in the "system buffer
- >unavailable" counter. I guess this would be a NICE/NML example I'm looking for.
- >Or can they be lifted directly from structures in kernel mode without too much
- >work? I suspect this is how the undocumented SDA command SHOW DECNET/DATALINK
- >did it (which stopped working at VMS 5.5).
-
- To which Ian Kitching (systimk@uk.ac.anglia-polytechnic.vaxa) responded by
- sending me a modified pascal program from the 1987 Decus SIG tape that provides
- a continuous display of the ethernet counters. All the counters are available
- using a sensemode QIO to the ethernet driver (no black magic required). I
- should have read the I/O user's guide (I just didn't expect it would be that
- easy). Thanks Ian.
-
-
- Carl Karcher Internet: KARCHER@WAISMAN.WISC.EDU
- Waisman Center Bitnet: KARCHER@WISCMACC
- University of Wisconsin-Madison PSTnet: (608) 263-5896
-