  1. From: jww@hpfcbig.SDE.HP.COM (Jim Wichelman)
  2. Date: Tue, 21 Jul 1992 16:40:15 GMT
  3. Subject: Re: Running HP clients on a Sun with OpenWin
  4. Message-ID: <55720002@hpfcbig.SDE.HP.COM>
  5. Organization: HP SESD, Fort Collins, CO
  6. Path: sparky!uunet!darwin.sura.net!wupost!sdd.hp.com!hpscdc!hplextra!hpfcso!hpfcbig!jww
  7. Newsgroups: comp.sys.sun.misc
  8. References: <1992Jul20.132222.1647@philabs.philips.com>
  9. Lines: 47
  10.  
  11. | We recently acquired a few HP workstations 
  12. | and now I have a couple questions.
  13. | I apologize if my questions have been answered
  14. | in this forum before, but I've only recently begun to 
  15. | peruse the HP newsgroup.
  16. | 1) I am unable to get HP clients (e.g.: hpterm or more importantly
  17. |    HP-VUE itself) to display their output
  18. |    on a Sun running OpenWin (version 2 or 3). If I wait long
  19. |    enough, however, the HP developed client eventually pops up
  20. |    a window on the Sun server, and works as advertised.
  21. |    Long enough is usually more then 10 minutes. Unfortunately,
  22. |    HP-VUE itself never comes up, at least not over a 3 day weekend ;-).
  23.  
  24.  
  25.    This problem is in the OW3.0 X11/NeWS server and has been reported to Sun.  
  26.    The Sun bug id# is 1076332.
  27.  
  28.    Tools using the HP Motif 1.1 library hang for 15 minutes when they attempt
  29.    to connect to the server supplied with OpenWindows 3.0.  This problem does 
  30.    not occur with the MIT X11R4 server or the OpenWindows 2.0 X11/NeWS server.
  31.   
  32.    Setting the following resource in the X11/NeWS server will resolve
  33.    this problem:
  34.  
  35.       <client>*useColorObj: false
  36.  
  37.    NOTE: This workaround is not supported.  It may cease to prevent the
  38.          problem in the future.
  39.  
  40.    If the SAIC VUE product is also being used under OpenWindows 3.0, this
  41.    resource may cause the VUE colors to behave incorrectly on any tool for
  42.    which the useColorObj resource was set to "false".  Therefore it is
  43.    recommended that this resource only be set in the OpenWindows 3.0 X11/NeWS
  44.    server and only for those tools which are using the HP Motif1.1 library
  45.    AND are displayed on the OpenWindows 3.0 X11/NeWS server (until Sun
  46.    provides a patch to fix this bug).
  47.  
  48. FYI:
  49.    You can get VUE running natively on Sun (under the X11/NeWS or MIT servers)
  50.    from SAIC (Science Applications Internaltional Corp) in San Diego CA.
  51.  
  52. Jim Wichelman
  53. Hewlett-Packard
  54. jww@fc.hp.com
  55.