- Path: sparky!uunet!cis.ohio-state.edu!ucbvax!PAN.SSEC.HONEYWELL.COM!thompson
- From: thompson@PAN.SSEC.HONEYWELL.COM ((jt) John Thompson)
- Newsgroups: comp.sys.apollo
- Subject: re: 425t EISA bus
- Message-ID: <199207300122.AA17188@pan.ssec.honeywell.com>
- Date: 30 Jul 92 01:22:54 GMT
- Sender: daemon@ucbvax.BERKELEY.EDU
- Distribution: world
- Organization: The Internet
- Lines: 45
-
-
- > >The 4xxT series nodes were marketed to have no EISA expansion capabilities.
- > >However, they obviously have an EISA bus, since they can take an ATR or ITR
- > >card. This leads me to ask two questions --
- >
- > Sorry, but they don't have an EISA bus at all. The ATR/ITR/Ethernet
- > cards are *ISA* cards (aka AT bus style cards). The "bus" in the 425t
- > is NOT a full ISA bus like the Dn3000/3500/4000/4500/5000 or 425s but
- > it is a crippled bus. It does not support dma. I forget if there
- > are other limitations.
- Okay. I had heard that it was crippled in some way, but didn't know how. That
- (unfortunately) makes sense. Sigh.
-
- > >2) There are now expanders out for the 700 series that convert a single EISA
- > > slot to a 7-slot(?) EISA bus, via (I believe) a card w/ extender cable,
- > > ...
- > Different animule altogether. That's a *real* EISA bus as opposed to
- > a crippled ISA bus.
- Unfortunately, probably the same animal. I may be wrong, but I assume from
- the description that the EISA expansion runs into the single slot, and thence
- to the rest of the bus. Assuming that's true, I'd have an EISA bus feeding
- into a crippled ISA bus. No work'll get done through that setup. :-(
-
-
- Oh well. I had hoped to be able to make some 425t nodes act as ethernet
- machines only (or use the expander to get another slot), and use the
- slot for an ExaTape card (Pertec reel-to-reel), or an Ikon card (Versatec
- differential parallel printers), or a <something_else_altogether> but I
- guess it is not to be.
-
-
- -- jt --
- John Thompson
- Design Services Engineer / Sys-Admin
- Honeywell, SSEC
- Plymouth, MN 55441
- thompson@pan.ssec.honeywell.com
-
- What do I know? I'm just a Token Administrator.
- *************************************************************************
- * This e-mail correspondence is a work of fiction. Any similarity *
- * between the views presented and actual views, personal or corporate, *
- * living, dead, or still to be conceived, is pure coincidence. *
- *************************************************************************
-
-