- In article <115201@glidden.UUCP>, bill@glidden.UUCP (Bill Glidden) writes:
- |> Sometimes when I first boot Coherent, my com2r port won't function
- |> until I have accessed the port com2pl.
- On some machines (I don't know which ones), the interrupts are
- "activated" until a polled access is done. I'm told that DOS is
- always pooled, so this hardware difference is overlooked. My machine
- has the same problem, and I just permanently changed it to polling.
-
- -paul black-