  1. Newsgroups: comp.dcom.modems
  2. Path: sparky!uunet!zaphod.mps.ohio-state.edu!wupost!darwin.sura.net!jvnc.net!johnson
  3. From: johnson@tigger.jvnc.net (Steven L. Johnson)
  4. Subject: Re: Why is my WB that slow in PEP-mode ?
  5. Message-ID: <1992Jul25.193713.14160@tigger.jvnc.net>
  6. Originator: johnson@tigger.jvnc.net
  7. Sender: news@tigger.jvnc.net (Zee News Genie)
  8. Nntp-Posting-Host: tigger.jvnc.net
  9. Organization: JvNCnet
  10. References: <1992Jul19.113314.16182@jr.rhein-main.de>  <1992Jul19.181846.17442@jr.rhein-main.de> <Brp704.Gv1@jwt.UUCP> <rhhm-3f.mccrate@netcom.com> <1992Jul25.015349.14966@telesys.tnet.com>
  11. Date: Sat, 25 Jul 1992 19:37:13 GMT
  12. Lines: 23
  13.  
  14. kreed@telesys.tnet.com (Kevin W. Reed) writes:
  15. >mccrate@netcom.com (Joe McCrate) writes:
  16. >>john@jwt.UUCP (John Temples) writes:
  17. >>>>Have to disable compression at all ( ATS190=0 ).
  18. >>>>Then I have the same rates with either T2500 or WB.
  19. >>>I would say it's more correct to set S191=6.
  20. >                                       ^^^^
  21. >>But in my Telebit manual there is no such register as S196.
  22. >                                                       ^^^^
  23. >Read Again....
  24.  
  25. ...and S191 isn't in the manual either.  It's in the separate addendum.
  26. "This register applies only to PEP connections when data compression is
  27. enabled (S190 is not equal to 0)."
  28.  
  29. S190=1S191=7 allow both old PEP compression and V.42bis; prefer V.42bis.
  30. S190=1S191=6 would disable old PEP compression but would allow V.42bis
  31.              to other WB's.
  32. S190=0       disables compression (s191 doesn't matter).
  33.  
  34. At least that's how I read it, and maybe that's what Joe said also.
  35.  
  36. -Steve
  37.