home *** CD-ROM | disk | FTP | other *** search
/ 300 Favorite Games / 300GAMES.iso / 170 / oakflat.hlp < prev    next >
Text File  |  1992-10-29  |  24KB  |  433 lines

  1.  
  2.                --<<< SIMULATOR COMMAND SUMMARY LIST v3.1 >>>--
  3.  
  4.         A                        FUEL                    SHELL
  5.         ACCIDENT                 I                       SHIELD ON/OFF
  6.         ALARM TEST               INSPECTION              SOUND ON/OFF
  7.         AUTO                     MANUAL                  SRCP ON/OFF 
  8.         AUTO SHUTDOWN            PRCP ON/OFF             SPEED n  
  9.         COLOR                    RPRV OPEN/CLOSED        SPRV OPEN/CLOSED
  10.         DAMAGE                   PRETEST                 TARGET
  11.         DAMAGE CONTROL ON/OFF    QUIT                    TOWER PUMP ON/OFF
  12.         DELAY n                  RATE                    TURBINE TRIP
  13.         DEMAND ON/OFF            REFUEL                  V
  14.         DEMO                     REPAIRS                 VALUE
  15.         DOCS                     RESTART                 VALVE 1 OPEN/CLOSED
  16.         DOCUMENTATION            RESTORE                 VALVE 2 OPEN/CLOSED
  17.         EVACUATE                 RUN UNTIL n             VER
  18.         EMERGENCY POWER          SAVE                    VIEW ON/OFF
  19.         EXIT                     SCRAM
  20.  
  21.            All of these commands may be entered by pressing <F7> 
  22.                   and typing the command at the prompt.
  23.  
  24.  
  25.  
  26.                --<<< SIMULATOR COMMAND QUICK HELP LIST >>>--
  27.  
  28.    A = AUTO START Command.
  29.    ACCIDENT = Simulates a sudden loss-of-coolant accident.
  30.    ALARM TEST = Tests all of the audible alarms if SOUND is active. 
  31.    AUTO = Activates Automatic Control Mode.
  32.    AUTO OFF = Initiates an Automatic Shutdown and then ends the simulation.
  33.    AUTO SHUTDOWN = Initiates an Automatic Shutdown then repairs/refueling.
  34.    COLOR = Optimizes the simulators display for a color monitor.
  35.    DAMAGE = Sets the quality of PCS and SCS to POOR (results in damage).
  36.    DAMAGE CONTROL ON = Activates automatic Damage Control Computer.
  37.    DAMAGE CONTROL OFF = De-activates automatic Damage Control Computer.
  38.    DELAY n = Activates a n second pause after each simulated hour (n = 1-60).
  39.    DEMAND ON = Activates Varying Demanded Power levels option.
  40.    DEMAND OFF = De-activates Varying Demanded Power Level option.
  41.    DEMO = Activates the interactive Demo Mode.
  42.    DOCS = View DOCUMENTATION using HYPERhelp.
  43.    DOCUMENTATION = View DOCUMENTATION using HYPERhelp.
  44.    EMERGENCY POWER = Supplies up to 3 days (72 hrs) of emergency pump power.
  45.    EVACUATE = Initiates a plant evacuation and then shuts down the plant.
  46.    EXIT = Quit the simulation immediately to DOS.
  47.    FUEL = Describes the amount of fissionable material in the fuel rods.
  48.    I = INSPECTION command.
  49.    INSPECTION = Reports the last NRC inspection of PCS and SCS.
  50.    MANUAL = De-activates Automatic adjustment of temp/power control settings.
  51.    MONO = Optimizes the simulators display for a monochrome monitor.
  52.    PRCP ON = Turns on the Primary Reserve Coolant Pump.
  53.    PRCP OFF = Turns off the Primary Reserve Coolant Pump.
  54.    PPRV OPEN = Opens the Primary Pressure Release Valve.
  55.    PPRV CLOSED = Closes the Primary Pressure Release Valve.
  56.    PRETEST = Tests all simulated reactor components prior to starting.
  57.    QUIT = Quits the simulation displaying your final score.
  58.    RATE = Describes the rate at which fuel is used up within the reactor.
  59.    REFUEL = Replaces the reactors fuel rods to 100%.
  60.    REPAIR = Does a complete repair job on all systems having any damage.
  61.    RESTART = Restarts the simulator and resets all settings.
  62.    RUN UNTIL n = Run the simulator until the n day is reached (n = 1 - 2000).
  63.    SCRAM = Immediately takes the reactor off-line in an emergency.
  64.    SHELL = Exits to a DOS prompt until "EXIT" is entered at a DOS prompt.
  65.    SHIELD ON = Activates an anti-neutron radiation shield, lowers radiation.
  66.    SHIELD OFF = Turns off the SHIELD option.
  67.    SPEED n = Sets the calculate to view ratio for simulated hours (n = 1-24).
  68.    SOUND ON = Activates the SOUND option.
  69.    SOUND OFF = De-activates the SOUND option.
  70.    SPRV OPEN = Opens the Secondary Pressure Release Valve.
  71.    SPRV CLOSED = Closes the SPRV if the valve is open.
  72.    SRCP ON = turns on the Secondary Reserve Coolant Pump.
  73.    SRCP OFF = Turns off the Secondary Reserve Coolant Pump.
  74.    TARGET = Allows for manual setting of Demanded Power level.
  75.    TOWER PUMP ON = Turns on the Cooling Tower Pumps.
  76.    TOWER PUMP OFF = Turns off the Cooling Tower Pumps.
  77.    TURBINE TRIP = By-passes the Steam Turbines in emergency.
  78.    V = Value command.
  79.    VALUE = Displays the current value of the power generated by the plant.
  80.    VALVE 1 OPEN = By-passes Steam Turbine Group #1 in emergency.
  81.    VALVE 1 CLOSED = Closes the by-pass valves for Turbine Group #1.
  82.    VALVE 2 OPEN = By-passes Steam Turbine Group #2 in emergency.
  83.    VALVE 2 CLOSED = Closes the by-pass valves for Turbine Group #12.
  84.    VER = Displays the simulators version and operating mode (AT or Not).
  85.    VIEW ON = Activates automatically changing view screens.
  86.    VIEW OFF = De-activates automatically changing view screens.
  87.  
  88.  
  89.  
  90.                  --<<< SIMULATOR COMMAND DETAIL LIST >>>--
  91.  
  92.    (A description of the available commands at the <F7> Command Prompt)
  93.  
  94.   A = AUTO START Command.
  95.  
  96.   ACCIDENT = Simulates a sudden loss of coolant accident where there is a
  97.           profound loss of coolant.  For the purpose of the simulator,
  98.           a rapid loss of coolant accident could empty the primary coolant 
  99.           loop of all coolant in less than 20 hours.  Counter measures to 
  100.           replace the coolant and stop the leak could slow, or even stop a 
  101.           meltdown.  Once this command is entered it can not be aborted.  
  102.           If the option creates a reactor core meltdown the simulation 
  103.           run is ended.  Only use this option to see how devastating such 
  104.           an accident could be, and to practice emergency procedures for 
  105.           such an event.
  106.  
  107.    ALARM TEST = Sounds the hourly temperature change alarm, the attention 
  108.           alarm, the warning alarm, and the emergency alarm to test the audio 
  109.           system in the computer.  If the sound is turned OFF no alarms will
  110.           be heard during the test.  Use the SOUND command to turn the 
  111.           speaker back ON.
  112.  
  113.    AUTO = Automatically adjusts the simulators control settings to maintain 
  114.           the power output at or near 100%. MANUAL reverses the command.  
  115.           Controlled by the Auto Adjustment computer, AUTO will adjust 
  116.           CONTROL RODS, PCP, SCP, and ECP to maintain a consistent output, 
  117.           and will automatically repair major plant damage (Damage > 25%) 
  118.           and refuel the reactor when needed (Using the AUTO SHUTDOWN 
  119.           command).  It will not maintain coolant levels with the PRIMARY 
  120.           and SECONDARY RESERVE COOLANT PUMP.
  121.  
  122.    AUTO OFF = Initiates the Automatic ShutDown Procedures which will
  123.           set the CONTROL RODS = 0 and turn off the RESERVE COOLANT PUMPS
  124.           if they are activated.  This procedure is activated automatically
  125.           while in the AUTO mode and the FUEL REMAINING < 11 or the TOTAL
  126.           DAMAGE > 24%.  Once the reactor is shutdown the simulation will
  127.           automatically end and your performance will be evaluated.
  128.  
  129.    AUTO SHUTDOWN = Initiates the Automatic ShutDown Procedures which will
  130.           set the CONTROL RODS = 0 and turn off the RESERVE COOLANT PUMPS
  131.           if they are activated.  This procedure is activated automatically
  132.           while in the AUTO mode and the FUEL REMAINING < 11 or the TOTAL
  133.           DAMAGE > 24%.  When the reactor is shutdown, repairs and/or 
  134.           refueling procedures will be initiated if the simulator is in 
  135.           AUTO or DEMO mode.
  136.  
  137.    AUTO START = Starts the simulator in AUTO mode, but in addition to the
  138.            normal settings, the DOUBLE option, the DAMAGE CONTROL option,
  139.            and the DEMAND option are all activated.
  140.  
  141.    DAMAGE = Sets the Quality of the workmanship of both the Primary and 
  142.           Secondary Coolant Systems to POOR.  The effect of this is to create 
  143.           substantial amounts of damage to the plant.
  144.  
  145.    DAMAGE CONTROL ON = Instructs the computer to initiate Damage Control 
  146.           automatically on any significant damage found in the plant.  The
  147.           equivalent manual command would be the <F8> function.  The 
  148.           automatic system activates emergency repairs when an individual 
  149.           systems damage exceeds 6%.  If the fuel level is less than 12% 
  150.           then repairs are started at damage equal to, or greater than 
  151.           5%.  Coolant Levels are also monitored and Reserve Coolant is 
  152.           pumped into the loops as needed via the RCP.
  153.  
  154.    DAMAGE CONTROL OFF = Turns off automatic Damage Control.
  155.  
  156.    DELAY n = Activates a n second pause after each simulated hour that 
  157.           passes.  Should be used when the user wants to slow the amount 
  158.           of time between simulated hours.  Many new users will find this 
  159.           option very helpful as they are learning the simulation.  To 
  160.           turn of the delay use the DELAY 0 command.  
  161.           
  162.    DEMAND ON = The Demanded Power Level is displayed on the Main Control 
  163.           Panel display as " % DMD ", and indicates how much power should be 
  164.           generated at that time.  The usual Demand is 100%, but this will be 
  165.           randomly changed when Demand is set ON.  The TARGET command allows
  166.           users to manually set the DEMAND level from the command prompt.
  167.          
  168.    DEMAND OFF = Turns off changing Demanded Power Level option.
  169.  
  170.    DEMO = This command is used do demonstrate the operation of the simulator.
  171.           It will PRETEST and power up the plant with the following settings:
  172.            AUTO ON    FAST    SHORT    BLANK ON    DAMAGE CONTROL ACTIVATED
  173.                         DEMAND ACTIVATED    RUN UNTIL 100
  174.           These settings will remain in effect through-out the simulation 
  175.           unless they are de-activated.  To de-activate the DEMO mode use
  176.           the MANUAL or AUTO command.  The DEMO command will initiate the
  177.           PRETEST command if DEMO is entered when the core is at 65°F.  
  178.           Entering the command at any other time will activate the DEMO mode
  179.           but will not PRETEST any systems.
  180.  
  181.    DOCS = DOCUMENTATION Command.
  182.  
  183.    DOCUMENTATION = Displays the simulators help file (OAKFLAT.DOC) using
  184.           HYPERhelp.  The cursor keys, <PgUp>, <PgDn>, <Home>, and <End>
  185.           will view different parts of the file, while <ESC> quits
  186.           HYPERhelp and returns back to the simulator.
  187.  
  188.    EMERGENCY POWER = On of the likely causes of a catastrophic accident in a
  189.           nuclear power plant is a power outage.  If for any reason the
  190.           plants internal electrical power fails, it is unable to pump 
  191.           coolant to maintain the cores temperature within safe limits.
  192.           The EMERGENCY POWER command supplies 3 days (72 hrs) worth of
  193.           emergency back up power for the coolant pumps.  In the case of
  194.           power outage enter the command and then immediately shut down the
  195.           plant for repairs.
  196.  
  197.    EVACUATE = The EVACUATE command initiates an evacuation of all plant 
  198.           personal and does an automatic shutdown on the plant.  The 
  199.           evacuation command should only be used during a catastrophic 
  200.           accident that can not be stopped any other way.  Be sure to 
  201.           start the evacuation soon enough for all plant personal to reach
  202.           a safe distance before the core melts.
  203.  
  204.    EXIT = Quit the simulation without displaying your final score, or
  205.           the option or restarting the simulation or quit to DOS.  Once
  206.           the EXIT command is entered at the command prompt, the screen
  207.           is cleared and the simulation has aborted back to DOS.  All 
  208.           information about the simulation is lost.  This command should
  209.           only be used to quickly exit the simulation when the operator
  210.           DOES NOT want his or her evaluation.  To receive an evaluation
  211.           the QUIT command must be used.
  212.  
  213.    FUEL = The FUEL command describes the percentage of fissionable materials
  214.           in the fuel rods currently in the reactor.  Each time the plant is
  215.           re-fueled the exact percentage of fissionable materials in the
  216.           rods varies.  Normally the percentage is between 2.5% and 3.5%
  217.           the command can aslo be used to change the percentage to any value
  218.           between 2.5% and 3.5%.  A higher percentage will generate more heat 
  219.           using less fuel. 
  220.  
  221.    I = INSPECTION command.
  222.  
  223.    INSPECTION = Reports the last NRC inspection info on the Primary System 
  224.           (reactor, PCS, & part of the Heat Exchanger, and the Secondary 
  225.           System (part of Heat Exchanger, SCS, Condenser, & Cooling Towers).
  226.  
  227.    MANUAL = Turns off automatic output control, so the simulator will depend
  228.           on the users input of CONTROL ROD, PCP, and SCP settings to 
  229.           maintain constant power output.  To de-activate the manual control 
  230.           command, enter the AUTO of DEMO command at the prompt.  
  231.  
  232.    PRCP ON = Activates the Primary Reserve Coolant Pump, moving reserve
  233.           coolant from the PCS to the SCS.  This increases the amount of
  234.           primary coolant while reducing the reserve coolant level.  To
  235.           de-activate the option, use the PRCP OFF command.
  236.  
  237.    PRCP OFF = Turns off the Primary Reserve Coolant Pump.
  238.  
  239.    PPRV OPEN = Opens the Primary Pressure Release Valve and lowers the
  240.           pressure in the primary loop.  As the pressure drops, so will the
  241.           reactor and heat exchangers temperatures.  Since the steam is 
  242.           really just super heated primary coolant, the coolant level in 
  243.           the PCS drops each hour.  NOTE: Once the valve is open it must 
  244.           be closed or all of the primary coolant could be lost if the 
  245.           valve is left open for too long.  Watch the coolant levels while 
  246.           using this option.  
  247.    
  248.    PPRV CLOSED = Closes the PPRV if the valve is open and has no effect if 
  249.           the valve is already closed.
  250.  
  251.    PRETEST = Tests all simulated reactor components prior to starting
  252.           the reactor from a complete power down, including a test of
  253.           Alarm System (if the SOUND is ON).  The reactor core is also
  254.           preheated before power up.  This reduces the chances of coolant 
  255.           system damage and adds 1000 points to the score.
  256.  
  257.    QUIT = Quits the simulation displaying your final score, and restart the 
  258.           simulation or quit to DOS.
  259.  
  260.    RATE = The RATE command describes the rate of fuel use within the reactor.
  261.           The rate will be shown as the percentage of fuel used per day.
  262.  
  263.    REFUEL = Replaces the reactors fuel rods after the core temperature
  264.           drops to  62° F.  Any repairs needed are done automatically
  265.           before the refueling is started.  Once the refueling is complete,
  266.           the main display appears with the simulator indicating the change
  267.           in fuel level, days simulated, damage, and expenses.
  268.  
  269.    REPAIR = Does a complete repair job on all systems having any damage.
  270.           The amount of time needed and the costs of repairs are based
  271.           on the amount of damage present at the time of repairs.  The
  272.           days needed to complete the repairs are added to the days simulated
  273.           variable, and the expenses of the repairs are added to the 
  274.           expenses.
  275.  
  276.    RESTART = Restarts the simulator from the title screen, all current
  277.           simulator settings and values are lost.  It has the same effect
  278.           as exiting the simulation and re-running the simulator from the
  279.           DOS prompt.
  280.  
  281.    RUN UNTIL = Allows the user to set the number of days the simulator will 
  282.           run before evaluation.  The default number of days is 1000, but 
  283.           it can be set between 1 and 2000.
  284.  
  285.    SCRAM = All Control Rods are immediately inserted back into the
  286.           reactor core to cause the spontaneous shut down of the thermal
  287.           nuclear reaction.  The simulator will properly shut down the
  288.           reactor to begin cooling down for repairs.  Use this command
  289.           only for extreme emergencies since it is very expensive!
  290.  
  291.    SHELL = Exits the user to a DOS prompt.  To return to the simulator type
  292.           "EXIT" at the DOS prompt and the user will return to the simulation
  293.           without effecting the simulator's current run.
  294.  
  295.    SHIELD ON = Activates an advanced electronic radiation shield that will
  296.           reduce (not eliminate) radiation exposure.  The shield will reduce
  297.           the number of neutrons that escape the standard protective 
  298.           shielding by 60%.  The cost of this added protection is the loss 
  299.           of all supplemental views (<F9> screens), and a lower hourly 
  300.           score.  To de-activate the option use the SHIELD OFF command.  
  301.           The SHIELD option can be activated and de-activated as needed.
  302.  
  303.    SHIELD OFF = Turns off the SHIELD option.
  304.  
  305.    SOUND ON = Toggles the Speaker Sound Status on and off.  If the Status 
  306.           Line displays " SND " the SOUND option is activated.    
  307.  
  308.    SOUND OFF = Turns off the SOUND option.  Once the command is entered, the
  309.           Status Line will change displaying a "NoSND" indicating the SOUND 
  310.           option is off.
  311.  
  312.    SPEED n = The optional setting for length, which displays n hours worth of 
  313.           plant operations with each display pass.  The startup default value
  314.           is n = 1, display 1 hours worth of operation with each display 
  315.           pass.  To return the speed to the default value, enter SPEED 1 at 
  316.           the command prompt.
  317.  
  318.    SPRV OPEN = Opens the Secondary Pressure Release Valve and lowers the 
  319.           pressure in the primary loop.  As the pressure drops, so will the
  320.           condenser temperature and turbine output.  Since the steam is super
  321.           heated secondary coolant, the coolant level drops in the SCS.
  322.           NOTE: Once the valve is opened using this command, it must be shut
  323.           or all the secondary coolant could be lost.  Use the SPRV CLOSED
  324.           command to shut the valve and carefully watch the coolant levels 
  325.           while using this command.
  326.  
  327.    SPRV CLOSED = Closes the SPRV if the valve is open and has no effect if 
  328.           the valve is closed.
  329.  
  330.    SRCP ON = Activates the Secondary Reserve Coolant Pump, moving reserve
  331.           coolant from the RCS to the SCS.  This increases the amount of
  332.           secondary coolant while reducing the reserve coolant level.  To
  333.           de-activate the option, use the SRCP OFF command.
  334.  
  335.    SRCP OFF = Turns off the Secondary Reserve Coolant Pump.
  336.  
  337.    TARGET = Sets the Demanded Power Level to a percentage between 10% and
  338.           100%.  This command is useful when the AUTO or DEMO options are
  339.           activated.  The computer will automatically adjust the control
  340.           settings to maintain the power output at the demanded percentage.
  341.           To use the command , enter "TARGET " followed be the requested
  342.           target demand level.  To set the level at 80% enter "TARGET 80"
  343.           at the <F7> command prompt.  To reset the demand level to 100% 
  344.           enter "TARGET 100", and to display the status of the option type
  345.           "TARGET" alone at the command prompt.
  346.  
  347.    TOWER PUMP ON = Activates the pumps responsible for pumping coolant from 
  348.            the CONDENSER to the COOLING TOWERS and back again.  The coolant
  349.            flows through the coils inside the CONDENSER to cool the secondary
  350.            coolant as it comes from the TURBINES on its way back into the
  351.            STEAM GENERATOR.  If the TOWER PUMPS are not activated the 
  352.            CONDENSER will overheat and damage will occur.  When in AUTO mode
  353.            the pumps will automatically activate when the CONDENSER COILS
  354.            reach 96°F.  The pumps will also de-activate at 96° while in any
  355.            mode.
  356.                       
  357.    TOWER PUMP OFF = De-activates the TOWER PUMPS from the command prompt.
  358.  
  359.    TURBINE TRIP = Automatically opens Steam Valves #1 and #2, thus by-passing
  360.           the Turbines and thus the generation of electrical power.  The 
  361.           steam is still produced, it just isn't allowed to turn turbines and 
  362.           generate power.  Once a TURBINE TRIP is initiated it can not be 
  363.           stopped, and a significant core overhaul will be needed.  Be
  364.           certain you need to use this command before entering it.  It should
  365.           only be used in case of extreme emergency.
  366.  
  367.    V = Value command.
  368.  
  369.    VALUE = Displays the current value of the power generated by the plant.
  370.           The starting price is $21.49 per mega-watts per hour.  The value
  371.           is increased by refueling and pretesting the reactor prior to 
  372.           power up.
  373.  
  374.    VALVE 1 OPEN = Opens the by-pass valves for steam flowing through Turbine
  375.           Group #1.  When this valve is open a 50% drop in power output is
  376.           is seen and once open, it will remain that way until the valve is
  377.           closed with a VALVE 1 CLOSED command.  If both VALVE #1 and #2 are
  378.           open, no power is generated since all steam is by-passed from the
  379.           turbines.  This has the same effect as a Turbine Trip but unlike
  380.           the turbine trip it can be aborted by closing the valves
  381.  
  382.    VALVE 1 CLOSED = Closes the by-pass valves for Turbine Group #1.
  383.  
  384.    VALVE 2 OPEN = Opens the by-pass valves for steam flowing through Turbine
  385.           Group #2.  When this valve is open a 50% drop in power output is
  386.           seen, and once open it will remain that way until the valve is
  387.           closed with a VALVE 2 CLOSED command.  If both VALVES #1 and #2 are
  388.           open, no power is generated since all steam is being by-passed from
  389.           the turbines.  This has the same effect as a Turbine Trip but 
  390.           unlike the turbine trip it can be aborted by closing the valves
  391.  
  392.    VALVE 2 CLOSED = Closes the by-pass valves for Turbine Group #2.
  393.  
  394.    VER =  Displays the simulators version number and the mode it is running
  395.           in.  An "(AT)" indicates the program is running on a 80286 computer
  396.           or better.  If the "(AT)" is not displayed then the program is 
  397.           running on a PC/XT class computer.
  398.  
  399.    VIEW ON = Activates the automatic changing of the view screen.  Every
  400.           15 seconds the view screen will change to the next <F9> screen.
  401.           If any screen is changed manually using the <F6> or <F9> keys it
  402.           will reset the 15 second timer to 0.
  403.  
  404.    VIEW OFF = De-activates automatically changing view screen.
  405.           
  406.  
  407.  
  408.  
  409.                      --<<< SIMULATOR HOT KEY LIST >>>--
  410.  
  411.       <F1> = Display the Command Summary/Help File (OAKFLAT.HLP)
  412.  
  413.       <F2> = Enter Control Rod Setting.
  414.  
  415.       <F3> = Enter Primary Coolant Pump Rate.
  416.  
  417.       <F4> = Enter Secondary Coolant Pump Rate.
  418.  
  419.       <F5> = Enter Reserve Coolant Pump Rate.
  420.  
  421.       <F6> = Display Main Control Panel.
  422.  
  423.       <F7> = Enter Simulator Command.
  424.  
  425.       <F8> = Damage Control.
  426.  
  427.       <F9> = Display/Change Simulator Status Reports.
  428.  
  429.       <F10> = More Function Key Help While On-Line.
  430.  
  431.       <KEYPAD CURSOR KEYS> = Change Forward/Backward Simulator Status Reports.
  432.  
  433.