- Fixed Bugs:
- -----------
- 1. Set baud rate as 19200/9600/4800/2400 bps, key in T<CR>AT<CR>...
- sequence there will be no response from TA.
- 2. AT*HCn's descrption in on-line help is wrong.
- 3. AT&F doesn't update AA LED status.
- 4. For USA version, if switch type is AT&T point-to-point, sometimes
- layer 1 can not activate.
- 5. For USA version, if switch type is NI1, callback function does not work.
- 6. The received packet length of D-channel is not correct.
- 7. Issuing "AT*Ax",x=0,2-7 to set the speed of DTE port 2 other than 115.2
- Kbps and saving to the user's profile by issuing "AT&W0Z0". After power
- off and on the TA, DTE port 2 does not accept any AT command until
- issuing command to DTE port 1 firstly.
- 8. CAPI 2.0 driver can not be used with CANDI.
- 9. Issuing "ATC$" to view EPA will get some garbage.
- 10. For DTE port2, TA can not send SETUP message with Low Layer Compatibility
- while making an outgoing call.
- 11. When using the phone features and trying to send BUSY to the caller
- Flash/5, the TA128 sends DISCONNECT with 'Call reject' instead of
- 'User busy'.
- 12. While intercom or 3 way conference, only Phone 1 can answer an incoming
- call. Phone 2 should be able to answer the call.
-
- New Implementation:
- -------------------
- 1. Caller ID display for POTS ports.
- When telephone call is coming, if physical DTE port is not occupied
- by any logical DTE channels, Caller ID and Calling ID will be displayed
- when s84.4=0.
- 2. AT*GC1: 2 changes.
- (1). Compare Calling Party Number (CGPN) with the stored numbers from the
- right digit to the left digit. So 8005552000 will match 5552000.
- (2). Based on the shorter one, so the CGPN can be longer or shorter than
- the stored numbers.
- 3. Leased line function. Using following command to configure:
- 3.1. ATDCn n=1,2,3 excites leased line connection on originate mode.
- DC1 - excites leased line connection using B1 channel on originate
- mode
- DC2 - excites leased line connection using B2 channel on originate
- mode
- DC3 - excites leased line connection using both B1 and B2 channel
- on originate mode
- 3.2. ATABn n=1,2,3 excites leased line connection on answer mode.
- AB1 - excites leased line connection using B1 channel on answer mode
- AB2 - excites leased line connection using B2 channel on answer mode
- AB3 - excites leased line connection using both B1 and B2 channel on
- answer mode
- 3.3. AT&In n=0,1,2,3 normal/leased line options
- &I0 - normal dial-up phone line. (default)
- &I1 - leased line function in B1 channel only, dial-up function in
- B2 channel
- &I2 - leased line function in B2 channel only, dial-up function in
- B1 channel
- &I3 - leased line function in both B1 and B2 channel.
- 4. Feature phone function: flash/6 - designate local phone to answer incoming
- call which ringing another phone.
- 5. Add "AT&W" to save DTE#2 B-channel protocol in NVRAM: If you first
- time upload firmware that includes "AT&W" function for DTE#2, please set
- the B channel protocol and set it into NVRAM (AT&W).
-
-
-
-
- -----------------------------------------------------------------------------
-
-
-
-
- January 23, 1997
-
- Release Note on Omni TA128 Version 2.00a (public betatest !)
- =============================================================
-
-
-
- 1.The firmware's file names for various switch type are as follows:
-
- FILENAME SWITCH TYPE
- 1.1 "OI_E200A" ------ DSS1
- 1.2 "OI_A200A" ------ USA
- 1.3 "OI_G200A" ------ 1TR6 (GERMANY only)
-
- 2.Fixed the Bugs:
- =================
- 2.1 For AOC function, a second call delete the charging information from
- channel B1, but not real. After the next charging unit come for B1
- channel, the lost units shows correctly again and the A/B adapter send
- this accumulated units as 16 kHz metering pulse to the connected phone.
- By the way, the phone display wrong charging information.
- 2.2 It's necessary to analysis the High-Layer Compatibility information
- element, especially G4 fax. An incoming call with G4 fax have to be
- routed to correspondable a/b adapter.
- 2.3 Making an outgoing data call to a BUSY TA may get "NO CARRIER" instead
- of "BUSY".
- 2.4 While calling an unassigned number using analog port, the inband
- information will come from switches. But the TA128 sends a busy tone
- instead of connect this inband information.
- 2.5 For Japanese version, while making an outgoing phone call with
- subaddress using analog port, then there are two errors in SETUP
- message:
- 1) the length of called party number is not correct.
- 2) missing the byte of AFI ( Authority and Format Identifier ) for
- called party subaddress with the type of NSAP X.213/ISO 8348 AD2.
- 2.6 While making a user-to-user information ( using ATT command ), the TA
- send wrong message to switch.
- 2.7 For s50 function, while the value of s50 is more then 128, making a
- data call will cause TA reset.
- 2.8 The answer side sets "ATE0Q1" "AT*G4" or "AT*G5". while calling back a
- incoming call ,the message "CallBack ATDIS0" will be displayed.
- 2.9 Fixed the bug in the comformance test of Singapore.
- 2.10 The modem will crash when the server reguest PAP but Win95 require
- encrypted password.
- 2.11 For PPP/MP, the second call will wait 2 seconds to dial out after the
- first passes authentication.
- 2.12 Issuing "ATCG", the activated of layer 1 fails.
- 2.13 For s124 setting, there are some problems to send LCP-echo.
- 2.14 The timer for S124 value is incorrect to send LCP-echo.
-
-
- 3.Newly implemented features
- ============================
-
- 3.1 Sync Data
- -------------
- 3.1.1. AT&M1: asynchronous (=async) command, synchronous (=sync) mode.
- At call site, issue "AT&M1" and "ATB11" ( V.110, sync 64K ), then
- LLC with sync mode will be included in the SETUP message.
- AT answer site, only issue "AT&M1", the Elite will check LLC of
- incoming SETUP message and connect with sync data.
- 3.1.2. AT&M3: synchronous mode.
- V25bis command set for this synchronous mode is available.
- AT*I1 have to be issued for enabling V25bis command set.
-
- 3.2 CAPI 2.0
- ------------
- 3.2.1 A public-beta version of the CAPI 2.0 driver was released
- simultaneously with the F/W version 2.00a.
- Supported Layer 2 and Layer 3 protocols are:
- X.75/transparent,
- X.75/T.70 (for T-Online),
- X.75/ISO8208 (for European File Transfer)
- HDLC/transparent
- 3.2.2 Two applications on the same PC can work concurrently, each using
- one of the two B-channels.
-
- 3.3 Miscellaneous
- -----------------
- 3.3.1 S50, inactivity timer. The Elite counts when there is no data flow
- in or out of the RS-232 serial port. A connection is disengaged when
- the counter reaches the preset value. Set '0' to disable this
- function. This function is available in PPP protocol.
-
-
-
- =============================================================================
-
-
-
-
- December 13, 1996
-
- Release Note on Omni TA128 Version 2.00
- ========================================
-
-
- "DSS1" firmware CRC checksum: 1032
- ========================================
- Windows95 ID for DSS1: UNIMODEM9E96B92C
- Windows95 ID for JAPAN: UNIMODEMCEDD2728
- Windows95 ID for TAIWAN:UNIMODEM6AAF4CFC
- Windows95 ID for KOREA: UNIMODEMAA7AD78F
- ========================================
-
-
-
-
- 1.The firmware's file names for various switch type are as follows:
-
- FILENAME SWITCH TYPE
- 1.1 "TA128E.200" ------ DSS1
- 1.2 "TA128A.200" ------ USA
- 1.3 "TA128G.200" ------ 1TR6 (GERMANY only)
-
- 2.Fixed the Bugs:
- =================
- 2.1 PPP/MP BOD delay timer does not work.
- 2.2 The DTE port 2 ATDL command cause the response to be showed on DTE port 1.
- 2.3 POTS ports still answers to the unmatched MSN number.
- 2.4 The analog call can not send LLC (Low Layer Capability) while set
- S80.4=1 or S80.7=1.
- 2.5 Security function on V.110 doesn't work.
- 2.6 The stored call back number ( by AT*HCn ) can not be erased by doing
- hardware reset.
- 2.7 For security functions there are two kinds of messages that can be
- used at the TA prompt. For example, "Password" and "PassWord",
- "CORRECT" and "Correct". Now "PassWord" and "Correct" are the
- only correct messages .
- 2.8 After V.110 connection, the item "Receive Byte" of "ATI3" displays
- incorrect value.
- 2.9 For U model of USA version, issuing AT&T8 or AT&T10 causes the TA to
- loose the SPIDs.
- 2.10 Issuing ATZI1 will get "ERROR", it should be "OK".
- 2.11 While receiving a Facility message with AOC_S, the TA will send a
- STATUS.
-
- 3.Newly implemented features
- ============================
-
- 3.1 CAPI.DLL v1.1 Profile A
- -----------------------------
- 3.1.1 A public betatest version 0.96 of the CAPI 1.1 profile A driver for
- Windows (CAPI.DLL, 16-bit) was released simultaneously with the
- f/w version 2.00
- The supported B-channel layer 2 and layer 3 protocols are:
- HDLC / transparent (used for some network connections with WISPA, etc)
- X.75 / transparent (used for most standard connections, eg. to BBS)
- X.75 / T.70NL (used for the German T-Online Service)
- X.75 / ISO-8208 (used for "EFT" = Euro File Transfer)
- Bit Transparent (for some G3 Fax applications).
- Two applications on the same PC can work concurrently, each using
- one of the two B-channels.
-
- [Note] We established a public mailing list on the Internet for
- testing this CAPI.DLL. If you are interested, please
- subscribe to this mailing list:
- send an eMail to "majordomo@zyxel.co.at" and in the message
- body write following two lines:
- --------------------------------------------
- subscribe capi-testers your.name@site.domain
- end
- --------------------------------------------
- where "your.name@site.domain" is your full Internet eMail
- address.
- If you had subscribed successfully you will receive a
- confirmation of your subscription in an eMail within minutes.
- The "Welcome to the capi-testers mailing list" eMail contains
- more background information ....
-
- 3.1.2 EAZ to MSN mapping function for CAPI mode. Users can use
- AT&Zn=xxx/sss/, n=0-9 (denotes the EAZ), xxx = phonenumber, sss =
- subaddresss to do this mapping. For outgoing calls, the Elite
- receives "Source EAZ" (0-9) from the application and uses the
- appriopriate phone number as Calling_Party_Number/Subaddress.
- For incoming calls, the Elite checks Called_Party_Number/Subaddress
- and uses the matched phone number register's pointer (0-9) as
- "RequestedEAZ" to the applications.
-
- 3.2 Charging Information
- ------------------------
- 3.2.1 AOC (Advice Of Charging) function: now you can use "ATCH?" to view
- the charge information of the last call if the network had sent the
- message. Please check with your ISDN Central Switching Office if any
- of the following EuroISDN supplementary services - according to the
- ETSI specifications - could be actived (because they are not
- supported in all European countries !)
- AOC-S/currency = Advice of Charging on call Setup time
- AOC-D/currency AOC-D/units = Advice of Charging During a connection
- AOC-E/currency AOC-E/units = Advice of Charging at the End of a call
- 3.2.2 Metering Pulse function ("ATS89.6=1") in case of the "AOC-D/units"
- ISDN supplementary service: for Germany (16 kHz), Switzerland (12 kHz)
- and Austria (12 kHz). Therefor it is necessary to set the correct
- ISDN country code ! Please check the current ISDN country code with
- the command "AT#H"
-
- [Note] Users can use the following command to change the country code:
- ATS38=4 for enable changing country code function.
- AT#Gxxx for enter country code xxx.
-
- ISDN country code list:
- Sweden 250 HongKong 242
- Taiwan 238 Germany 237
- Italy 236 Japan 234
- Austria 233 Switzerland 225
-
-
- ATTENTION: please don't set any other ISDN country code than specified
- otherwise your ZyXEL ISDN product won't work correctly and
- then the behaviour for D-channel singalling would cause
- malfunction (especially if some country specific features
- will not be supported or implemented in the ISDN Central
- Switch firmware for the ISDN basic rate access in your
- country) !
-
-
- 3.3 New protocols for DTE port #2
- ---------------------------------
- 3.3.1 implementation of X.75 and V.120.
- 3.3.2 multiauto mode auto-detect/connect PPP, X.75, V.120 protocols.
- 3.3.3 DTE port 2 will answer to matched "called party number" with MSN
- setting (refers to AT&ZI5 command).
- 3.3.4 One more S register bit is to configure DTE port 2 to answer the
- incoming data call when DTE port 1 is busy (in connected state),
- even if the MSN (at&ZI5) is not matched.
- S87.7 = 0 : DTE port 2 will only answers the incoming data
- call with matched MSN number (default).
- S87.7 = 1 : DTE port 2 answers incoming call when port 1 busy.
- (useful for server applications)
-
- 3.4 New POTS port features
- --------------------------
- 3.4.1 Intercom / Transfer / MultiAnswer / Call Waiting /
- - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- 3-Way Switch mode / 3-Way Mixing mode , and all the features
- will be handled by the TA128 per se, users don't need to subscribe
- those features from the phone company (therefore no extra charge
- for them).
-
- [Note]: Due to hardware limitation, only the newer TA128 is able to
- support all the POTS port features. Please check your hardware
- by issuing "AT&V6" to view the "Full-featured" status.
-
- +----------+----------------------+---------------------+
- | Features | Full-featured=1(Yes) | Full-featured=0(No) |
- +----------+----------------------+---------------------+
- | 3.4.2 | Yes | Yes |
- +----------+----------------------+---------------------+
- | 3.4.3 | Yes | No |
- +----------+----------------------+---------------------+
- | 3.4.4 | Yes | No |
- +----------+----------------------+---------------------+
- | 3.4.5 | Yes |Yes,but no 3-way conf|
- +----------+----------------------+---------------------+
- | 3.4.6 | Yes |Yes,but no 3-way conf|
- | | |and no Intercom |
- +----------+----------------------+---------------------+
- | 3.4.7 | Yes |Yes,but no 3-way conf|
- | | | mixing mode |
- +----------+----------------------+---------------------+
- | 3.4.8 | Yes |Yes,but some are void|
- +----------+----------------------+---------------------+
- The old hardware can be upgraded by reworking at customer's
- expense. Please contact your ZyXEL authorized distributor
- for more detailed information how to upgrade, if needed.
-
- 3.4.2 Global Reception
- - - - - - - - - - - -
- 3.4.2.1 Two S register bits to configure POTS port global reception
- S87.0 = 0 :Enable POTS port 1 to accept global call (default)
- = 1 :Disable POTS port 1 to accept global call
- S87.1 = 0 :Enable POTS port 2 to accept global call (default)
- = 1 :Disable POTS port 2 to accept global call
- 3.4.2.2 Two S register bits to configure whether to discard or ignore the
- incoming global call when POTS port is busy
- S79.0 = 0 :Ignore POTS port 1 incoming call when it's busy (default)
- = 1 :Discard POTS port 1 incoming call when it's busy,
- TA128 sends "RELEASE COMPLETE" with cause code "busy"
- S79.1 = 0 :Ignore POTS port 2 incoming call when it's busy (default)
- = 1 :Discard POTS port 2 incoming call when it's busy,
- TA128 sends "RELEASE COMPLETE" with cause code "busy"
-
- 3.4.3 InterCom:
- - - - - - - - -
- 3.4.3.1 You get the first dial tone by picking up the handset.
- 3.4.3.2 Press flash key (or click hook switch) to get the second dial tone
- then press phone number "2",the other local phone will start to
- ring.
- 3.4.3.3 When local phone answered, Intercom established.
- 3.4.3.4 During Intercom one can still dial out to get second connection
- and put local phone on hold. During Intercom any of the local
- phone flash key pressed will get first dial tone then press 0
- to get second dial tone and dial the remote phone number.
- 3.4.3.5 Before the remote phone answered, press flash will cancel the
- second dial attempt and back to the local phone (InterCom).
- 3.4.3.6 When remote phone answered start to talking to the remote
- press flash/0 can switch to local phone and put remote phone
- on hold.
- 3.4.3.7 press flash/3 to joint the 3 way conference, 2 local and 1 remote.
-
- 3.4.4 Answering the incoming call during InterCom
- - - - - - - - - - - - - - - - - - - - - - - - - -
- 3.4.4.1 When incoming call comes in you will hear the alerting signal
- from the telephone handset.
- 3.4.4.2 Press flash/5 to reject the incoming call
- 3.4.4.3 Or press flash/3 to answer incoming call and create 3 way
- mixing mode conference conversation with existing intercom.
- 3.4.4.4 Or press flash/0 to answer incoming call and put
- original call on hold.
- 3.4.4.5 Press flash/0 can switch original(internal) and
- incoming(external) call back and forth.
- 3.4.4.6 press flash/3 to joint 3 way conference.
- 3.4.4.7 During 3 way mode one of local phone hangup do not tear down
- remote connection.
-
- 3.4.5 Call waiting / MultiAnswer
- - - - - - - - - - - - - - - - -
- 3.4.5.1 s79.2 = 0 : POTS port 1 call waiting (multi-answer) disabled
- = 1 : POTS port 1 call waiting (multi-answer) enabled
- (default setting)
- s79.3 = 0 : POTS port 2 call waiting (multi-answer) disabled
- = 1 : POTS port 2 call waiting (multi-answer) enabled
- (default setting)
- 3.4.5.2 When talking with remote(via B channel) party, another call
- comes in, if the call-waiting setting enabled you will hear
- the alerting signal from the telephone handset.
- 3.4.5.3 Press flash to get dial tone and then you can either press 3 to
- create 3 party mixing conference with existing external call or
- press 0 to answer the incoming call and put previous call on hold.
- 3.4.5.4 If flash/0 selected Press more flash/0 can switch these two calls.
- 3.4.5.5 Press flash/2 can transfer one of external call to another
- local phone.
- 3.4.5.6 Or press flash/3 to joint as 3 way mixing conference.
-
- 3.4.6 Call transfer (transfer remote call)
- - - - - - - - - - - - - - - - - - - - - -
- 3.4.6.1 When talking with remote (external, via B channel) party,
- press flash to get dial tone then press 2 for local
- connection(Intercom).
- 3.4.6.2 Transfer the call by put handset to the cradle (hangup phone) or
- wait local phone to answer.
- 3.4.6.3 After peer local phone answer, intercom connection establised
- (talking with local) and remote phone on hold.
- 3.4.6.4 Hangup the phone the external phone call will then transfer
- to the another local phone or ..
- 3.4.6.5 Press flash/0 can switch original(remote) and local call.
- 3.4.6.6 Press flash/3 to joint 3 way mixing mode conference.
- 3.4.6.7 During the 3 way mixing mode conference any of the local phone
- hangup does not disconnect the remote connection.
-
- 3.4.7 Three way (2 external + 1 local)
- - - - - - - - - - - - - - - - - - - -
- 3.4.7.1 If one of B channel accupied by phone call.
- 3.4.7.2 Local phone press flash will get first dial tone then press 0 to
- get second dial tone and you can start to dial the phone number
- to get the second connection. And put first call on hold.
- 3.4.7.3 Before the second connection establish, press flash again will
- cancel the connect attempt and back to the previous call.
- 3.4.7.4 If second connection established press flash/0 can switch back
- to the previous (first) call.
- 3.4.7.5 Press flash/5 will disconnect the current connection and
- switch back the another call or ...
- 3.4.7.6 Press flash/2 can transfer one of external call to another
- local phone,if another local phone did not answer press
- flash to cancel the transfer.
- 3.4.7.7 Press flash/3 to joint the three way conference.
-
- 3.4.8 Telephone keypad command summary
- - - - - - - - - - - - - - - - - - - -
- 3.4.8.1 Flash key (or click hook switch) :
- * cancel the second dial connection attempt
- 3.4.8.2 Flash/2 :
- * dial to local phone, Intercom
- 3.4.8.3 Flash/0 :
- * answer the incoming call and put the existing call on hold
- * initiate and ready to dial the second phone call and put
- the first call on hold
- 3.4.8.4 Flash/3 :
- * create the 3 party mixing mode conference
- 3.4.8.5 Flash/5 :
- * reject the second incoming phone call
- * tear down current phone connection
-
- 3.5 Japan Version
- -----------------
- 3.5.1 For Japanese ISDN, the TA128 can detect the frame of V.110 57600
- bps in multi-auto mode.
- 3.5.2 For Japanese ISDN, link layer is always active (layer 2 in state 7).
- 3.5.3 POTS port can dial subaddress from telephone keypad.
- Keypad dialing sequence "xxxxx*yyyy#" where xxxxx is the phone
- number, yyyy is the subaddress.
-
- 3.6 Miscellaneous
- -----------------
- 3.6.1 Support KOREA ISDN switch KT-1B and KT-10A.
- TA128U, TA128 (S/T) two models available for KOREA.
- 3.6.2 Keypad signalling function for Sweden.
- 3.6.3 For PPP/MP:
- S87.2=0, CHAP/PAP for authetication conversion, (default setting).
- S87.2=1, PAP only for authetication conversion.
- S61.3=0, MP data sent in rotate mode (default setting).
- S61.3=1, MP data sent in split mode.
- 3.6.4 S79.7=0, respones "RELEASE COMPLETE" with cause "call rejected"
- while receiving an incoming call after issuing ATH1.
- S79.7=1, respones "RELEASE COMPLETE" with cause "user busy"
- while receiving an incoming call after issuing ATH1.
- 3.6.5 For USA version, now user can enter Directory Number:
- ATDNx=s, x=0,1, s=phonenumber.
-
- =============================================================================
-
-
-
-
- Release Note on Omni TA128 Version 1.01 09/23/1996
- =======================================
-
-
- 1. The uploadable firmware file name for different switch type shown below
-
- FILENAME SWITCH TYPE
- 1.1 "TA128E.101" ------ DSS1
- 1.2 "TA128A.101" ------ USA
- 1.3 "TA128G.101" ------ 1TR6 (GERMANY only)
-
- 2. Fixed bugs
- -------------
- 2.1 DTE port 2 "ATH" command or DTR drop cause DTE port 1 drop B channel.
- 2.2 Suspend and resume feature of analog port.
- 2.3 Analog port call bumping problem at PPP/MP connection.
- TA128 send "TermReq" to peer before drop B channel.
- 2.4 The command of ATM0 for speaker control.
- 2.5 TA128 Crash caused by Windows 95 "PLUG AND PLAY".
- 2.6 The EPA screen is broken, When issue "atc$" and press 2.
- 2.7 Setting S89=5 cause the setting of bundle call lost.
- 2.8 Setting S35.4=1 and pressing the Data/Voice button will make the
- TA128 only dialout the first 9 numbers only.
- 2.9 The compatibility problem with CISCO LCP.
- 2.10 DTE port 2 call setup blocks DTE port 1 data transmition and
- receiving.
- 2.11 PPP/MP reliability problem (worst case stress test).
- 2.12 Multiple application's problem of CAPI driver.
- 2.13 After V.110 connection, the item "Receive Byte" of "ATI3" displays
- incorrect value.
- 2.14 One can't assign AT&Zn=bxxxxx for a/b adapter into NVRAM at location
- n the letter 'b' can not be saved.
- 2.15 S38.0=1 & S44.3=1 don't work. (repeatly dialing default number)
- 2.16 If you make a call to the Elite and the DTR is low, then wait for the
- modem to ring for a few times and hang up the call before it connect.
- After that if you try to bring DTR high, the "Buffered" RING messages
- will be sent to the DTE.
- 2.17 After ISDN loopback test ( AT&T9, AT&T10 ), the Elite can not place
- an outgoing call in the first try.
- 2.18 Connection problem with ELSA MicroLink ISDN TL/V.34 when the ELSA has
- V42bis handshaking activated ( which is default ).
- 2.19 While received a Facility message with AOC_S, the TA128 will send a
- STATUS.
- 2.20 AOC's problem if switch send DISCONNECT or RELEASE message with AOC_E.
- This will cause incorrect value of charge information.
- 2.21 POTS port call setup problem when ALERTING message did not include
- PROGRESS INDICATOR information element.
-
- 3. New implemented features
- ---------------------------
- 3.1 Analog port global reception
- S87.0 = 0 : Enable POTS port 1 receive global call
- = 1 : Disable POTS port 1 receive global call
- S87.1 = 0 : Enable POTS port 2 receive global call
- 1 : Disable POTS port 2 receive global call
- 3.2 BACP/BAP protocol
- 3.3 SLIP async to sync convertion
- Issue ATB41 command to set outgoing/incoming service = SLIP
- convertion.
- 3.4 Type 1 security function.
- 3.5 AOC_D function: you can use "ATCH?" to view the charge information of
- last call if network had sent the message.
- 3.6 For Japanese ISDN, the TA128 can detect the frame of V.110 57600 bps
- in multi-auto mode.
- 3.7 CCP/V.42bis for all models
- The B1 LED will blinking when data compression on the B1 channel,
- same as B2.
- 3.8 CCP/STAC/V.42bis (The STAC is available on USA firmware only)
- The B1 LED will blinking when data compression on the B1 channel,
- same as B2.
- 3.9 New OMNI TA128 model with CCP/STAC feature for Europe and Japan.
- 3.10 Two DTE ports and two POTS ports always enabled for JAPAN version F/W,
- ignore the setting of "s125.0=x".
- 3.11 Loopback test for USA firmware.
-
- =============================================================================
-
-
-
-
- Release Note on Omni TA128 Version 1.00 07/24/1996
- =======================================
-
- 1. This version V1.00 is the first formal release version for Omni TA128,
- the prior firmware versions 0.xx are used for ß-test only. Please use
- ATUPX to update to V1.00. Please refer to chapter 13 of the user's manual
- for procedures of updating the firmware.
- The default settings of the older version may not comply with V1.00.
- It's recommended to reload the newer profile settings. Please press
- button switch for 3 seconds while turn on the OMNI TA128's power
- switch then the TA starts the hardware reset and load in the factory
- default settings followed by a selft-test at 115200bps DTE speed.
- CAUTION: all of the setting will be lost after the operation of
- "load factory default" including phone table, password,
- and profiles.
-
- 2. Please refers to the OMNI TA128 user's manual for detailed installation
- procedure, application examples, and advanced informations.
-
- 3. Known bugs to be corrected in the near future:
- 3.1 If DTE port 1 connected as PPP/MP, DTE port 2 DTR drop will tear down
- one of B channel temporarily.
- 3.2 Analog ports' suspend and resume features are unavailable yet.
- 3.3 Command ATM0 does not work.
-
-