home *** CD-ROM | disk | FTP | other *** search
/ Chip 1997 April / Chip_1997-04_cd.bin / ovladace / zyxel / firmware / 288re / 288re102.txt next >
Encoding:
Text File  |  1997-02-20  |  3.7 KB  |  100 lines

  1.                                                   ZyXEL Communications Corp.
  2.  
  3.                                                      edited by Manfred Recla
  4.  
  5.                                                             February 3, 1997
  6.  
  7.  
  8.  
  9.  
  10.  
  11.    Release Note on ZyXEL's "G3" Modem series (= U-288R/RE, U-336E/S)
  12.  
  13.    Version 1.02
  14.  
  15.    =================================================================
  16.  
  17.  
  18.  
  19.  
  20.  
  21.  1. Fix modem bugs :
  22.  
  23.  -------------------
  24.  
  25.     * Remote digital loop back may  fail for U-336S model:
  26.  
  27.       If we initiate RDL or RDLST from the LCD panel, it will fail .
  28.  
  29.     * leased line mode:
  30.  
  31.       When the line is broken under abnormal condition after a long period
  32.  
  33.       of time the modem may fail to restart handshaking.
  34.  
  35.     * command ATI0 response:
  36.  
  37.       The modem responses "2864" in old version.In new version, it will
  38.  
  39.       response according to different modem type:
  40.  
  41.          U-288RE will response "33601"
  42.  
  43.          U-336R  will response "33602"
  44.  
  45.          U-336S  will response "33603"
  46.  
  47.          U-336E  will response "33604"
  48.  
  49.     * In testing mode, the modem will not set pin 25 of RS232 active.
  50.  
  51.     * MNP4,MNP5 mode:
  52.  
  53.       Sometimes it can't send or receive data in MNP4,MNP5 mode.
  54.  
  55.     * V.32bis and ZyX-19k2 mode:
  56.  
  57.       If the initial setting contains "Q2&K3" and it connects by ZyX-19k2
  58.  
  59.       or V.32bis mode, the modem will hang after transmit a few characters.
  60.  
  61.  
  62.  
  63.  2. Change the modem factory default settings:
  64.  
  65.  ---------------------------------------------
  66.  
  67.     S6 is changed to 10 for Russia.
  68.  
  69.     S7 is changed to 45 for Taiwan (rack).
  70.  
  71.  
  72.  
  73.  3. Improve performance:
  74.  
  75.  -----------------------
  76.  
  77.     * Improve V.34 performance.
  78.  
  79.  
  80.  
  81.  4. Known Bug:
  82.  
  83.  -------------
  84.  
  85.     * Software flow control problem:
  86.  
  87.       The modem will lose data in software flow control mode at high
  88.  
  89.       connect speed.
  90.  
  91.     * AT&Wab, Remote write profile functuion error. Remote can't reset from
  92.  
  93.       profile b.
  94.  
  95.  
  96.  
  97.  
  98.  
  99.  
  100.  
  101. ---------------------------------------------------------------------------
  102.  
  103.  
  104.  
  105.  
  106.  
  107.  
  108.  
  109.                                                             January 16, 1997
  110.  
  111.  
  112.  
  113.    Release Note on ZyXEL's "G3" Modem series (= U-288R/RE, U-336E/S)
  114.  
  115.    Version 1.01
  116.  
  117.    =================================================================
  118.  
  119.  
  120.  
  121.  
  122.  
  123.  1. Add new features:
  124.  
  125.  --------------------
  126.  
  127.     * V.34bis 33600 bps, 31200 bps.
  128.  
  129.  
  130.  
  131.  2. Fix modem bugs :
  132.  
  133.  -------------------
  134.  
  135.     * V.32bis mode connection:
  136.  
  137.       Sometimes it can't sense the abnormal carrier drops.
  138.  
  139.     * Special dialing feature:
  140.  
  141.       Modem does not finish dialing of numbers specified after P modifier
  142.  
  143.       and hangs for a time specified in S7 register. For example when
  144.  
  145.       "ATDT9WP8W10-886-3-578-7045" is entered, modem will report "NO CARRIER"
  146.  
  147.     * Ring false alarm:
  148.  
  149.       When pulse dial  by the telephone set connected to modem, the modem
  150.  
  151.       will report ring.
  152.  
  153.     * Synchronous mode: (&M3)
  154.  
  155.       The modem will not give the answer tone when auto answer.
  156.  
  157.     * Compatibility:
  158.  
  159.       .Multi-Auto connection:
  160.  
  161.        The modem can't connect with Motorola Power 288 V.32bis mode .
  162.  
  163.       .Fail to connect at error control mode:
  164.  
  165.        Sometimes the modem will connect at none error control mode with
  166.  
  167.        Rockwell chip set based modem.
  168.  
  169.  
  170.  
  171.  3. Improve performance:
  172.  
  173.  -----------------------
  174.  
  175.     * Improve V.34 performance.
  176.  
  177.     * Improve answer tone detection sensitivity.
  178.  
  179.     * Improve the modem realibity.
  180.  
  181.  
  182.  
  183.  4. Known Bugs:
  184.  
  185.  -------------
  186.  
  187.     * Software flow control problem:
  188.  
  189.       The modem will lose data in software flow control mode at high connect
  190.  
  191.       speed.
  192.  
  193.     * AT&Wab, Remote write profile functuion error. Remote can't reset from
  194.  
  195.       profile b.