  1.              Appendix C to ZyXEL Elite 2864I User's Manual
  2.  
  3.  
  4.  
  5.                         Quick Reference Guide
  6.  
  7.  
  8.  
  9.                    For Firmware Version 2.05 and Up
  10.  
  11.  
  12.  
  13.  
  14.  
  15.   BASIC 'AT' COMMAND SET
  16.  
  17.  
  18.  
  19.   Command             Function & Description                             Ref.
  20.  
  21.  
  22.  
  23.   A/                  Re-execute the last command once.
  24.  
  25.   A>                  Re-execute the last command once or repeat the
  26.  
  27.                       last call up to 9 times. (See also S8)
  28.  
  29.   <any key>           Terminate current connection attempt when enter
  30.  
  31.                       in handshaking state.
  32.  
  33.   +++                 Escape sequence code, entered in data state, wait
  34.  
  35.                       for modem to return to command state.
  36.  
  37.   ATA                 Go on-line in answer mode. (See also S39b2, S43b6)
  38.  
  39.  
  40.  
  41.   ATBn    Bn          For internal modem: Handshake option              S28b7
  42.  
  43.           B0      *   Select CCITT V.22 for 1200 bps communication
  44.  
  45.           B1          Select Bell 212A standard for 1200 bps
  46.  
  47.   ATBnn               Select ISDN Teleservice                        S82,S102
  48.  
  49.                       'B' must be followed by two digits.
  50.  
  51.           B0n         X.75 :
  52.  
  53.           B00         X.75 Transparent
  54.  
  55.           B01         X.75 T.70
  56.  
  57.           B04         BTX (Datex-J)
  58.  
  59.           B10         V.110 User rate follows DTE speed (async)
  60.  
  61.                       User rate determined by in-band negotiation (sync)
  62.  
  63.           B11         V.110 sync 64K
  64.  
  65.           B13         V.110 user rate = 2400 bps                         S117
  66.  
  67.           B14         V.110 user rate = 4800 bps
  68.  
  69.           B15         V.110 user rate = 9600 bps
  70.  
  71.           B16         V.110 user rate = 14400 bps
  72.  
  73.           B17         V.110 user rate = 19200 bps
  74.  
  75.           B18         V.110 user rate = 38400 bps (async only)
  76.  
  77.           B20         V.120
  78.  
  79.           B40         PPP async to sync conversion
  80.  
  81.           B41         SLIP to sync HDLC conversion
  82.  
  83.   ATCBn   n=0-1       Configuration of embedded protocol analyzer       S84b1
  84.  
  85.           CB0         Disable the capture of B channel protocols
  86.  
  87.           CB1         Enable the capture of B channel protocols
  88.  
  89.   ATCCn   n=0-1       Configuration of embedded protocol analyzer       S84b0
  90.  
  91.           CC0         Disable the capture of DTE-DCE interface
  92.  
  93.                       protocols
  94.  
  95.           CC1         Enable the capture of DTE-DCE interface
  96.  
  97.                       protocols
  98.  
  99.   ATCDn   n=0-1       Configuration of embedded protocol analyzer       S84b2
  100.  
  101.           CD0         Disable the capture of D channel protocols
  102.  
  103.           CD1         Enable the capture of D channel protocols
  104.  
  105.   ATCEn   n=0-1       Call bumping control for PPP/MP and CCB           S85b0
  106.  
  107.           CE0         Disable the call bumping function
  108.  
  109.           CE1     *   Enable the call bumping function
  110.  
  111.   ATCG                Diagnostics & Hardwaretest
  112.  
  113.   ATCH?               Display the accumulated charging unit of the
  114.  
  115.                       last call.
  116.  
  117.   ATCI<prefix>        Prefix number string to be added to the
  118.  
  119.                       Calling-party-number before indicating to the
  120.  
  121.                       DTE when the type of number denotes
  122.  
  123.                       international.
  124.  
  125.   ATCK<DES_key>       Set the key for DES (Data Encryption Standard)
  126.  
  127.   ATCLn   n=0-2048    Maximum size of user data in a packet (number
  128.  
  129.                       of bytes)
  130.  
  131.   ATCL?               Enquire current setting of ATCLn
  132.  
  133.   ATCN<prefix>        Prefix number string to be added to the
  134.  
  135.                       Calling-party-number before indicating to the
  136.  
  137.                       DTE when the type of number denotes national.
  138.  
  139.   ATCPn   n=0-1       Loopback 4 control                                S83b0
  140.  
  141.           CP0         Disable Loopback 4
  142.  
  143.           CP1         Enable Loopback 4
  144.  
  145.   ATCRn   n=0-3   *0  Resumes a previoully suspended call, n is the
  146.  
  147.                       call identifier(Europe)
  148.  
  149.   ATCSn   n=0-3   *0  Suspend a call, n is the call identifier(Europe)
  150.  
  151.   ATCT                Clear buffer and start the embedded protocol
  152.  
  153.                       analyzer. Capture data immediately and start
  154.  
  155.                       timer.
  156.  
  157.   ATC$                Invoke the interpretation function of the
  158.  
  159.                       embedded protocol analyzer and display the
  160.  
  161.                       results on DTE
  162.  
  163.   ATDs                Dial s (number and options) that follows (see
  164.  
  165.                       also S38b0, S35b4). The options of s are listed
  166.  
  167.                       as follows :
  168.  
  169.           ,           Pause for a time specified in S6. Remaining
  170.  
  171.                       digits will be dialed as in-band DTMF.
  172.  
  173.           W           Wait for second dial tone. Remaining digits
  174.  
  175.                       will be dialed as in-band DTMF.
  176.  
  177.                       <ISDN numbering options>
  178.  
  179.           Y0      *   Unknown type of number
  180.  
  181.           Y1          International number
  182.  
  183.           Y2          National number
  184.  
  185.           Y3          Network specific number
  186.  
  187.           Y4          Subscriber number
  188.  
  189.           Y6          Abbreviated number
  190.  
  191.           Z0      *   Type of subaddress - NSAP with AFI=$50, IA5
  192.  
  193.                       characters
  194.  
  195.           Z2          Type of subaddress - user specified, IA5
  196.  
  197.                       characters
  198.  
  199.           N0      *   Unknown numbering plan
  200.  
  201.           N1          ISDN/Telephony numbering plan (CCITT E.164/
  202.  
  203.                       E.163)
  204.  
  205.           N3          Data numbering plan (CCITT X.121)
  206.  
  207.           N8          National standard numbering plan
  208.  
  209.           N9          Private numbering plan
  210.  
  211.           /           Called party subaddress delimeters
  212.  
  213.           A           Don't care (no Called Party Number information
  214.  
  215.                       element in the output SETUP message/ coming
  216.  
  217.                       call with any Called Party Number will be
  218.  
  219.                       granted)
  220.  
  221.   The format of s will be :
  222.  
  223.           [[Yn][Nn]called_party_Number][[W][,]]inband_dtmf_number
  224.  
  225.        or [[Yn][Nn]called_party_Number][/[Zn]called_party_subaddress/]
  226.  
  227.        or [A][/[Zn]called_party_subaddress/]
  228.  
  229.  
  230.  
  231.   ATDBs               Dial s (number and options) that follows
  232.  
  233.                       for the a/b adapter
  234.  
  235.   ATDIs               Dial s (number and options) that follows
  236.  
  237.                       for ISDN data call
  238.  
  239.   ATDL                Repeat last ATD command
  240.  
  241.   ATDMs               Dial s (number and options) that follows
  242.  
  243.                       for the internal fax/modem
  244.  
  245.   ATDNr=nnn...        User enters Directory Number nnnn...(USA)
  246.  
  247.           DN0         First DN number
  248.  
  249.           DN1         Second DN Number, if any
  250.  
  251.   ATDSn   n=0-39      Dial number stored in NVRAM at location 'n'.      S44b3
  252.  
  253.   ATDSn+Sm            For placing a bundle call with two separate phone
  254.  
  255.   ATDnnnn+mmmm        numbers
  256.  
  257.   ATEn                Command mode local echo of keyboard commands.     S23b0
  258.  
  259.           E0          Echo off
  260.  
  261.           E1 *        Echo on
  262.  
  263.   ATHn                On/off hook control
  264.  
  265.           H0 *        Hang up (on-hook) the modem or ISDN, same as 'ATH'
  266.  
  267.           H3          Hang up the a/b adapter
  268.  
  269.   ATIn                Display inquired information
  270.  
  271.           I0          Display product code, same as 'ATI'.
  272.  
  273.                       Results: 28641           (USA)
  274.  
  275.                                28642           (DSS1)
  276.  
  277.                                28643           (1TR6)
  278.  
  279.           I1          Display product information and ROM checksum
  280.  
  281.                       Results: Elite 2864I <switch>: V x.xx
  282.  
  283.                                Internal fax/modem: V x.xx
  284.  
  285.                                <checksum>
  286.  
  287.                       where <switch>= USA, DSS1, or 1TR6
  288.  
  289.           I2          Display link status report of internal fax/modem
  290.  
  291.           I3          Display link status report of ISDN call
  292.  
  293.   ATJAn   n=0-255 *48 Add-threshold for PPP/MP Bandwidth-On-Demand      S126
  294.  
  295.                       in Kbps unit,        
  296.  
  297.   ATJSn   n=0-255 *32 Sub-threshold for PPP/MP Bandwidth-On-Demand      S127
  298.  
  299.                       in Kbps unit
  300.  
  301.   ATKAxn  n=0-63  *0  Add-persist time interval for PPP/MP,          S85b1-7
  302.  
  303.                       BOD disabled if n=0
  304.  
  305.                       x= M(in Minute unit) or S(in Second unit)
  306.  
  307.   ATKSxn  n=0-63  *0  Sub-persist time interval for PPP/MP,         S125b1-7
  308.  
  309.                       x= M(in Minute unit) or S(in Second unit)
  310.  
  311.   ATLn    n=0-7  *4   Speaker volume control.The higher the value     S24b4-6
  312.  
  313.                       ,the higher the volume.
  314.  
  315.   ATMn                Speaker control.                                S21b1-2
  316.  
  317.           M0          Speaker always OFF.
  318.  
  319.           M1  *       Speaker ON until carrier is detected.
  320.  
  321.           M2          Speaker always ON.
  322.  
  323.           M3          Speaker ON after the last digit is dialed
  324.  
  325.                       out and OFF when carrier is detected.
  326.  
  327.   ATNn    n=0-7  *5   Ring volume control.'N0' will disable           S24b0-2
  328.  
  329.                       the ring function.
  330.  
  331.   ATO                 Return to on-line state
  332.  
  333.   ATO1                Force modem to request a retrain.
  334.  
  335.   ATPn    n=0-6       D-channel protocol selection(USA)                   S86
  336.  
  337.                       for American Version
  338.  
  339.           P0  *       Northern Telecom proprietary ISDN
  340.  
  341.           P1          National ISDN 1(1 SPID)
  342.  
  343.           P2          National ISDN 1(2 SPID)
  344.  
  345.           P3          reserved
  346.  
  347.           P4          AT&T proprietary point-to-point
  348.  
  349.           P5          AT&T proprietary point-to-multipoint(1 SPID)
  350.  
  351.           P6          AT&T proprietary point-to-multipoint(2 SPID)
  352.  
  353.   ATQn                Result code displayed                             S23b7
  354.  
  355.           Q0  *       Modem returns result code.
  356.  
  357.           Q1          Modem does not return result code.
  358.  
  359.           Q2          Modem returns result code but quiet after         S40b1
  360.  
  361.                       answering on a RING. (will not show in AT&Vn)
  362.  
  363.   ATSr.b=n            Set bit 'b' of S-register 'r' to value 'n'.
  364.  
  365.                       'n' is a binary digit '0' or '1'.
  366.  
  367.   ATSr.b?             Display value of bit 'b' of S-register 'r'.
  368.  
  369.   ATSr=n              Set S-register 'r' to value 'n'. 'n' must be a
  370.  
  371.                       decimal number between 0 and 255.
  372.  
  373.   ATSr?               Display value stored in S-register 'r'.
  374.  
  375.   ATSPIDr=nnn...      User enters Service Profile ID nnnn...(USA)
  376.  
  377.           SPID0       First SPID number
  378.  
  379.           SPID1       Second SPID Number, if any
  380.  
  381.   ATSPID?             Display the SPID setting(s)
  382.  
  383.   ATT                 Repeat last user-to-user information(Europe)
  384.  
  385.   ATTn<string>        The <string> will be sent to the called party
  386.  
  387.                       via an User-to-user information element in the
  388.  
  389.                       next message. Characters other than the alpha-
  390.  
  391.                       numerical values can be represented by <nnn>
  392.  
  393.                       in the string, where nnn is the unsigned value
  394.  
  395.                       of the character. The maximum number of
  396.  
  397.                       characters in the string is 31 for ETSI.
  398.  
  399.           T0          User-specific protocol
  400.  
  401.           T1          OSI high layer protocol
  402.  
  403.           T2          X.244
  404.  
  405.           T3          Reserved for system management convergence
  406.  
  407.                       function
  408.  
  409.           T4   *      IA5 characters
  410.  
  411.           T7          ITU-TS Recommendation V.120 rate adaption
  412.  
  413.           T8          Q.931 user-network call control message
  414.  
  415.   ATUPX               Upload firmware to the Flash EPROM
  416.  
  417.   ATVn                Verbal/Numeric result codes.                      S23b6
  418.  
  419.           V0          Display result code in numeric form. (See also
  420.  
  421.                       S35b7 and the result code table of 'ATXn')
  422.  
  423.           V1 *        Display result code in verbose form.
  424.  
  425.   ATXn    n=0-7  *5   Result code options, see the Options Table      S23b3-5
  426.  
  427.   ATZn    n=0-4       Reset modem and set power-on profile.           S15b5-7
  428.  
  429.           Zn          Reset modem and load user profile n (0-3).
  430.  
  431.           Z4          Reset modem and load factory settings.
  432.  
  433.   AT$                 Basic command summary help
  434.  
  435.  
  436.  
  437.  
  438.  
  439.   EXTENDED 'AT&' COMMAND SET
  440.  
  441.   Command             Function & Description                             Ref.
  442.  
  443.  
  444.  
  445.   &Bn                 Data rate, terminal-to-modem. (DTE/DCE)           S28b6
  446.  
  447.           &B0         DTE rate follows connection rate.
  448.  
  449.                       (See also S44b6)
  450.  
  451.           &B1  *      DTE/DCE rate fixed at DTE setting (See also S18,
  452.  
  453.                       S20, and S44b6)
  454.  
  455.   &Cn                 Carrier Detect (CD) options                       S21b4
  456.  
  457.           &C0         CD always ON (See also S42b7)
  458.  
  459.           &C1  *      CD tracks presence of carrier.
  460.  
  461.                       (See also S38b3, S42b7)
  462.  
  463.   &Dn                 Data Terminal Ready (DTR) options.              S21b6-7
  464.  
  465.           &D0         Ignore DTR signal, assume DTR is always ON.
  466.  
  467.           &D1         108.1, DTR OFF-ON transition causes dial of the
  468.  
  469.                       default number.  (See also 'AT*Dn' and S48b4)
  470.  
  471.           &D2  *      108.2, Data Terminal Ready, DTR OFF causes the
  472.  
  473.                       modem to hang up.
  474.  
  475.           &D3         Same as &D2 but DTR OFF causes the modem to
  476.  
  477.                       hang up and reset from profile 0.
  478.  
  479.   &En                 B channel line speed for ISDN data call
  480.  
  481.           &E0  *      64Kbps
  482.  
  483.           &E1         56Kbps (Default for American ISDN)
  484.  
  485.   &F                  Load factory settings to RAM as active
  486.  
  487.                       configuration.
  488.  
  489.   &Gn                 Guard tone options (for internal fax/modem)     S28b4-5
  490.  
  491.           &G0  *      No guard tone (within USA, Canada).
  492.  
  493.           &G2         1800 Hz guard tone.
  494.  
  495.   &Hn                 Data flow control, DTE/DCE.                     S27b3-5
  496.  
  497.           &H0         Flow control disabled.
  498.  
  499.           &H3  *      Hardware (CTS/RTS) flow control.
  500.  
  501.           &H4         Software (XON/XOFF) flow control.
  502.  
  503.   &Jn                 Bundle selection (See also S100)                S87b5-6
  504.  
  505.           &J0  *      Bundle connection is disabled
  506.  
  507.           &J1         Bundle connection is enabled in answer
  508.  
  509.                       mode only
  510.  
  511.           &J2         Bundle connection is enabled in call
  512.  
  513.                       mode only
  514.  
  515.           &J3         Bundle connection is enabled in both
  516.  
  517.                       directions
  518.  
  519.   &Kn                 Modem error control and data compression.       S27b0-2
  520.  
  521.           &K0         No error control.(Same as AT&K)
  522.  
  523.           &K1         MNP4 (See also S41b0).
  524.  
  525.           &K2         MNP4+MNP5 (See also S38b5, S41b0).
  526.  
  527.           &K3         V.42+MNP4.
  528.  
  529.           &K4  *      V.42+V.42bis, compatible with &K2 (See also S38b5).
  530.  
  531.   &Knn                ISDN data compression control
  532.  
  533.                       &K must be followed by two digits
  534.  
  535.                       V.42bis switch of the ISDN data call              S83b2
  536.  
  537.           &K00        Disable V.42bis (or disable reliable PPP)
  538.  
  539.           &K44        Enable V.42bis
  540.  
  541.   &Ln                 Modem and a/b adaptor address ambiguity           S84b5
  542.  
  543.                       resolution
  544.  
  545.           &L0         A/B adaptor first
  546.  
  547.           &L1         Fax/Modem first
  548.  
  549.   &Nn                 Modem link mode options (DCE/DCE).                  S19
  550.  
  551.                       (See also S43b7, S48b1)
  552.  
  553.           &N0  *      Multi-Auto, auto negotiate highest possible link
  554.  
  555.                       rate: V.34, ZyX 19200, ZyX16800, V.32bis, V.32,
  556.  
  557.                       V.22bis, V.22 and Bell 212A, G3 Fax
  558.  
  559.                       V.17/V.29/V.27ter and cellular modes. (See
  560.  
  561.                       also S38b4, S43b0, S43b1, S43b3 and S48b5)
  562.  
  563.           &N1         V.33 14400/12000 (models with 4-wire leased
  564.  
  565.                       line only).
  566.  
  567.           &N2         V.33 12000 (models with 4-wire leased line only).
  568.  
  569.           &N3         V.32 9600T/9600/7200T/4800
  570.  
  571.           &N4         V.32 9600/7200/4800
  572.  
  573.           &N5         V.32 4800
  574.  
  575.           &N6         V.29 9600 (models with 4-wire leased line only).
  576.  
  577.           &N7         V.29 7200 (models with 4-wire leased line only).
  578.  
  579.           &N8         V.29 4800 (models with 4-wire leased line only).
  580.  
  581.           &N9         V.27bis 4800 (models with 4-wire leased line only).
  582.  
  583.           &N10        V.27bis 2400 (models with 4-wire leased line only)
  584.  
  585.           &N11        V.26bis 2400 (4-wire leased line or 2-wire
  586.  
  587.                       half-duplex).(See also S35b2, S39b5)
  588.  
  589.           &N12        V.23 1200/75 (See also S48b3, S52b7).
  590.  
  591.           &N13        V.23 600/75 (See also S52b7).
  592.  
  593.           &N14        V.22bis 2400/1200
  594.  
  595.           &N15        V.22 1200
  596.  
  597.           &N16        V.21 300
  598.  
  599.           &N17        V.32bis 14400/12000/9600/7200/4800
  600.  
  601.           &N18        V.32bis 12000/9600/7200/4800
  602.  
  603.           &N19        V.32bis 7200/4800
  604.  
  605.           &N24        BELL 212A 1200
  606.  
  607.           &N25        BELL 103 300
  608.  
  609.           &N32        G3 Fax V.17/V.29/V.27ter
  610.  
  611.                       14400/12000/9600/7200/4800/2400 (See also S42b4).
  612.  
  613.           &N34        ZyXEL 19200
  614.  
  615.           &N35        ZyXEL 16800
  616.  
  617.           &N36        ZyXEL 14400
  618.  
  619.           &N37        ZyXEL 12000
  620.  
  621.           &N38        ZyXEL 9600
  622.  
  623.           &N39        ZyXEL 7200
  624.  
  625.           &N42        CELL 14400
  626.  
  627.           &N43        CELL 12000
  628.  
  629.           &N44        CELL 9600
  630.  
  631.           &N45        CELL 7200
  632.  
  633.           &N46        CELL 4800T
  634.  
  635.           &N62        V.34 28800
  636.  
  637.           &N63        V.34 26400
  638.  
  639.           &N64        V.34 24000
  640.  
  641.           &N65        V.34 21600
  642.  
  643.           &N66        V.34 19200
  644.  
  645.           &N67        V.34 16800
  646.  
  647.           &N68        V.34 14400
  648.  
  649.           &N69        V.34 12000
  650.  
  651.           &N70        V.34 9600
  652.  
  653.           &N71        V.34 7200
  654.  
  655.           &N72        V.34 4800
  656.  
  657.           &N73        V.34 2400
  658.  
  659.   &On                 Set default call type for conventional dialing  S83b4-5
  660.  
  661.                       commands
  662.  
  663.           &O0         ATDs, ATDPs, and ATDTs default to make fax/modem
  664.  
  665.                       calls
  666.  
  667.           &O2         ATDs, ATDPs, and ATDTs default to make ISDN
  668.  
  669.                       data calls
  670.  
  671.           &O3         ATDs, ATDPs, and ATDTs default to make calls
  672.  
  673.                       for the a/b adapter
  674.  
  675.   &Sn                 Data Set Ready (DSR) function selection.          S21b3
  676.  
  677.           &S0  *      DSR overridden, DSR always ON.
  678.  
  679.           &S1         DSR according to CCITT (ITU-TSS).
  680.  
  681.                       (See also S41b5, S44b4)
  682.  
  683.   &Tn                 Modem testing.
  684.  
  685.           &T0         Terminate test  in progress.
  686.  
  687.           &T1         Initiate Analog LoopBack (ALB) test.
  688.  
  689.           &T8         Initiate Analog LoopBack with self test (ALB+ST)
  690.  
  691.           &T9         Initiate ISDN loopback test
  692.  
  693.           &T10        Initiate ISDN loopback with self test
  694.  
  695.   &Vn                 View profile settings.
  696.  
  697.           &V0         View current active settings.
  698.  
  699.           &Vn         View the (n-1)th user profile settings (n=1-4)
  700.  
  701.           &V5         View factory default settings.
  702.  
  703.           &V6         View a/b adapter's setting
  704.  
  705.           &V8         System Resources Status
  706.  
  707.   &Wn     n=0-3       Write current settings to user profile n in
  708.  
  709.                       NVRAM.  (See also S35b6)
  710.  
  711.   &Yn                 Break handling.  (Destructive Break clears      S28b2-3
  712.  
  713.                       the buffer.  Expedited Break is sent
  714.  
  715.                       immediately to the remote system.)
  716.  
  717.                       For internal modem only
  718.  
  719.           &Y0         Destructive, expedited.
  720.  
  721.           &Y1  *      Nondestructive, expedited.
  722.  
  723.           &Y2         Nondestructive, unexpedited.
  724.  
  725.   &Zn=s   n=0-39      Write phone number s to NVRAM at location n
  726.  
  727.                       (n=0-39) use AT*Dn or ATS29=n to set the
  728.  
  729.                       default dial pointer.
  730.  
  731.   &ZIn=s  n=0-7       Assign the phone number (including
  732.  
  733.                       subaddress, if any) for various B-channel
  734.  
  735.                       protocols. In answer mode, these numbers
  736.  
  737.                       will be compared with the received called
  738.  
  739.                       party number and called party subaddress
  740.  
  741.                       information. The call will be accepted using
  742.  
  743.                       the specific protocol if the assigned number
  744.  
  745.                       of this protocol matches with the called
  746.  
  747.                       party number.
  748.  
  749.           &ZI0=s      Assign the phone number for X.75
  750.  
  751.           &ZI1=s      Assign the phone number for V.110
  752.  
  753.           &ZI2=s      Assign the phone number for V.120
  754.  
  755.           &ZI3=s      Assign the phone number for PPP async to
  756.  
  757.                       sync HDLC
  758.  
  759.           &ZI4=s      Assign the phone number for ISDN data
  760.  
  761.                       (Multi-Auto answering, auto detect the protocols)
  762.  
  763.           &ZI5=s      Assign the phone number for PPP async to
  764.  
  765.                       sync HDLC
  766.  
  767.           &ZI6=s      Assign the phone number for internal
  768.  
  769.                       fax/modem
  770.  
  771.           &ZI7=s      Assign the phone number for the a/b adapter
  772.  
  773.   &ZI?                Display the phone number (including subaddress
  774.  
  775.                       , if any) for various B-channel protocols
  776.  
  777.   &ZOx=s              Write own phone number (including
  778.  
  779.                       subaddress, if any). The number specified by
  780.  
  781.                       &ZOx will be used as the calling party number
  782.  
  783.                       while dialing
  784.  
  785.                       x = M(fax/modem), I(ISDN), or B(a/b adapter)
  786.  
  787.   &ZO?                Display the own phone numbers assigned via
  788.  
  789.                       the AT&ZOx=s command
  790.  
  791.   &Z?                 Display all the phone numbers stored in NVRAM.
  792.  
  793.  
  794.  
  795.  
  796.  
  797.   EXTENDED 'AT*' COMMAND SET
  798.  
  799.   Command             Function & Description                             Ref.
  800.  
  801.   *Cn                 Character length, including start, stop         S15b3-4
  802.  
  803.                       and parity bit.
  804.  
  805.           *C0  *      10-bit character length.
  806.  
  807.           *C1         11-bit character length.
  808.  
  809.           *C2         9-bit character length.
  810.  
  811.           *C3         8-bit character length.
  812.  
  813.   *Dn     n=0-39      Set default dial pointer at telephone               S29
  814.  
  815.                       directory location n.
  816.  
  817.           *D0  *      (See also S35b4 and S38b0)
  818.  
  819.   *En                 Internal modem error control negotiation.         S21b0
  820.  
  821.           *E0  *      if error control negotiation fails, keep the
  822.  
  823.                       non-error control connection.
  824.  
  825.           *E1         If error control negotiation fails,
  826.  
  827.                       disconnect the call (hang-up).
  828.  
  829.   *Gn                 Security function selection.                    S36b5-7
  830.  
  831.           *G0  *      Disable security function.
  832.  
  833.           *G3         Enable type 2 security, with password check.
  834.  
  835.           *G4         Enable type 2 security, with password check
  836.  
  837.                       and call back.
  838.  
  839.           *G5         Enable type 2 security, with password check
  840.  
  841.                       and call back, remote site enters the call
  842.  
  843.                       back number.
  844.  
  845.   *GCn                Call-back function selection.                    S119b0
  846.  
  847.           *GC0 *      Disable call-back function.
  848.  
  849.           *GC1        Enable call-back function
  850.  
  851.   *HCn    n=0-4       Modify call back phone number(AT*HCn=xxx)
  852.  
  853.   *HS                 Modify supervisory password (Default: 'ZyXEL').
  854.  
  855.   *Hn     n=0-39      Modify user password table at location n.
  856.  
  857.   *Qn                 Action taken when line quality changes.         S27b6-7
  858.  
  859.           *Q0         No action to poor signal quality.
  860.  
  861.           *Q1         Retrain action taken if signal quality is
  862.  
  863.                       poor.  (See also S41b2)
  864.  
  865.           *Q2  *      Adaptive rate, automatic fall-back or forward.
  866.  
  867.           *Q3         Disconnect if signal quality is poor.
  868.  
  869.   *T                  Recall the last CND (Caller ID) information.
  870.  
  871.   *V                  View password table
  872.  
  873.   *VC                 View call-back table
  874.  
  875.  
  876.  
  877.  
  878.  
  879.   FAX, FCLASS=2 'AT+F' COMMAND SET
  880.  
  881.   Command             Function & Description                             Ref.
  882.  
  883.  
  884.  
  885.   +<command>=<value>  Execute a command or set a parameter
  886.  
  887.   +<command>=?        Read permissible settings
  888.  
  889.   +<command>?         Read current setting
  890.  
  891.   +FAA=n              Auto answer mode parameter
  892.  
  893.           n=0         DCE to answer as set by +FCLASS
  894.  
  895.           n=1         DCE answers and auto-determines calling type
  896.  
  897.   +FBADLIN=<value>    Bad line threshold (number of consecutive bad lines for
  898.  
  899.                       a bad page parameter)
  900.  
  901.                       Determine if 'Copy Quality OK' on the T.30 flow chart.
  902.  
  903.                       <value>=0 to 255;  a value of 0 implies that error
  904.  
  905.                       checking is disabled.
  906.  
  907.   +FBADMUL=<value>    Error threshold multiplier
  908.  
  909.                       Determine if 'Copy Quality OK' on the T.30 flow chart.
  910.  
  911.                       <value>=0 to 255; a value of 0 implies that error
  912.  
  913.                       checking is disabled.
  914.  
  915.   +FBOR=n             Phase C data bit order
  916.  
  917.           n=0         Select direct bit order
  918.  
  919.           n=1         Select reversed bit order in receiving mode for phase C
  920.  
  921.                       data
  922.  
  923.   +FBUF?              Buffer size; read only parameter
  924.  
  925.                       Allow DTE to determine the characteristics of the DCE's
  926.  
  927.                       buffer size.
  928.  
  929.   +FCIG='string'      Local fax station ID string, for polling Rx
  930.  
  931.   +FCLASS=n           Service class selection
  932.  
  933.           n=0         Set to modem mode
  934.  
  935.           n=1         Set to Class 1 mode
  936.  
  937.           n=2         Set to Class 2 mode
  938.  
  939.           n=2.0       Set to Class 2.0 mode
  940.  
  941.           n=6         Set to ZFAX mode
  942.  
  943.           n=8         Set to Voice mode
  944.  
  945.           n=Z         Set to ZyXEL fax parallel port print and/or DRAM store
  946.  
  947.                       mode. (See also class Z 'AT+F' commands)
  948.  
  949.   +FCON               DCE response, fax connection made
  950.  
  951.   +FCQ=n              Copy quality check capability parameter
  952.  
  953.           n=0         No copy quality check capability
  954.  
  955.           n=1         Only check 1D phase C data
  956.  
  957.           n=2         Check both 1D and 2D phase C data
  958.  
  959.   +FCR=n              Capability to receive parameter
  960.  
  961.           n=0         DCE will not receive message data or poll a remote
  962.  
  963.                       device
  964.  
  965.           n=1         DCE receives message data or polls a remote device
  966.  
  967.   +FCTCRTY=<value>    ECM retry count; in Error Correcting Mode only
  968.  
  969.                       The sender will try to send a partial page 4 times.
  970.  
  971.                       <value>=0 to 255; units of 4 retries. If the Continue to
  972.  
  973.                       Correct (CTC) count is 0, it will not make any further
  974.  
  975.                       attempts.
  976.  
  977.   +FDCC=vr,br,wd,ln,  DCE capability parameters. Refer to EIA PN-2388 or
  978.  
  979.         df,ec,bf,st   user's manual for detailed descriptions
  980.  
  981.   +FDCS=vr,br,wd,ln,  Current session parameter. Refer to EIA PN-2388 or
  982.  
  983.         df,ec,bf,st   user's manual for detailed descriptions
  984.  
  985.   +FDIS=vr,br,wd,ln,  Current session negotiation parameters. Refer to
  986.  
  987.         df,ec,bf,st   EIA PN- 2388 or user's manual for detail descriptions.
  988.  
  989.   +FDR                Receive phase C data command, initiates document
  990.  
  991.                       reception
  992.  
  993.   +FDT [=df,vr,wd,ln] Transmit phase C data command, releases the DCE to
  994.  
  995.                       proceed with negotiation
  996.  
  997.   +FECM=n             Error correction mode control
  998.  
  999.           n=0         Error correcting mode is disabled
  1000.  
  1001.           n=2         Error correcting mode is enabled, handled by the DCE
  1002.  
  1003.                       alone, including buffering of partial pages
  1004.  
  1005.   +FET=n              End of page or document command
  1006.  
  1007.           n=0         More pages, same document
  1008.  
  1009.           n=1         End of document, another document follows
  1010.  
  1011.           n=2         No more pages or documents
  1012.  
  1013.           n=4         Procedure interrupt, another page follows
  1014.  
  1015.           n=5         Procedure interrupt, end of document, another document
  1016.  
  1017.                       follows
  1018.  
  1019.           n=6         Procedure interrupt, end of document
  1020.  
  1021.   +FK                 Orderly fax abort command
  1022.  
  1023.   +FLID='string'      Local ID string parameter
  1024.  
  1025.   +FLO=n              Flow control options
  1026.  
  1027.           n=0         No flow control
  1028.  
  1029.           n=1         Set XON/XOFF software flow control
  1030.  
  1031.           n=2         Set CTS/RTS hardware flow control
  1032.  
  1033.   +FLPL=n             Document for polling command
  1034.  
  1035.           n=0         The DTE has no document for polling
  1036.  
  1037.           n=1         Indicate document available for polling
  1038.  
  1039.   +FMDL?              Request DCE model
  1040.  
  1041.   +FMFR?              Request DCE manufacturer
  1042.  
  1043.   +FMINSP=n           Minimum phase C speed parameter
  1044.  
  1045.           n=0         2400 bps
  1046.  
  1047.           n=1         4800 bps
  1048.  
  1049.           n=2         7200 bps
  1050.  
  1051.           n=3         9600 bps
  1052.  
  1053.           n=4         12000 bps
  1054.  
  1055.           n=5         14400 bps
  1056.  
  1057.   +FPHCTO=<value>     DTE Phase C response timeout
  1058.  
  1059.                       Determine how long the DCE will wait for a command
  1060.  
  1061.                       after reaching the end of data when transmitting in
  1062.  
  1063.                       Phase C.
  1064.  
  1065.                       <value>=0 to 255; 100 ms units
  1066.  
  1067.   +FPTS=n             Page transfer status
  1068.  
  1069.           n=1         Received page good
  1070.  
  1071.           n=2         Page bad, retrain requested
  1072.  
  1073.           n=3         Page good, retrain requested
  1074.  
  1075.           n=4         Page bad, procedure interrupt requested
  1076.  
  1077.           n=5         Page good, procedure interrupt requested
  1078.  
  1079.   +FREL=n             Phase C received EOL alignment
  1080.  
  1081.           n=0         The EOL patterns are bit aligned as received.
  1082.  
  1083.           n=1         The last received bits of EOL patterns are byte
  1084.  
  1085.                       aligned by the DCE, with necessary zero fill bits
  1086.  
  1087.                       inserted. Refer to EIA PN-2388 for details.
  1088.  
  1089.   +FREV?              Request DCE revision
  1090.  
  1091.   +FSPL=n             Enable polling command
  1092.  
  1093.           n=0         Disable polling
  1094.  
  1095.           n=1         Enable polling
  1096.  
  1097.  
  1098.  
  1099.  
  1100.  
  1101.   FAX, FCLASS=2.0 'AT+F' COMMAND SET
  1102.  
  1103.   Command             Function & Description                             Ref.
  1104.  
  1105.  
  1106.  
  1107.   +<command>=<value>  Execute a command or set a parameter
  1108.  
  1109.   +<command>=?        Read permissible settings
  1110.  
  1111.   +<command>?         Read current setting
  1112.  
  1113.   +FAA=n              Auto answer mode parameter
  1114.  
  1115.            n=0        DCE to answer as set by +FCLASS
  1116.  
  1117.            n=1        DCE answers and auto-determines calling type
  1118.  
  1119.   +FBO=n              Phase C data bit order
  1120.  
  1121.            n=0        Select direct bit order
  1122.  
  1123.            n=1        Select reversed bit order in receiving mode for phase C
  1124.  
  1125.                       data
  1126.  
  1127.   +FBS?               Buffer size parameter, read only.
  1128.  
  1129.   +FCC=vr,br,wd,ln    DCE capability parameters. Refer to TIA-592 for details.
  1130.  
  1131.        df,ec,bf,st
  1132.  
  1133.   +FCLASS=n           Service class selection
  1134.  
  1135.            n=0        Set to modem mode
  1136.  
  1137.            n=1        Set to Class 1 mode
  1138.  
  1139.            n=2        Set to Class 2 mode
  1140.  
  1141.            n=2.0      Set to Class 2.0 mode
  1142.  
  1143.            n=6        Set to ZFAX mode
  1144.  
  1145.            n=8        Set to Voice mode
  1146.  
  1147.            n=Z        Set to ZyXEL fax parallel port print and/or DRAM store
  1148.  
  1149.                       mode. (See also class Z 'AT+F' commands)
  1150.  
  1151.   +FCO                DCE response, fax connection made
  1152.  
  1153.   +FCQ=<rq>,<tq>      Copy quality check capability parameter
  1154.  
  1155.                       Refer to TIA-592 for details.
  1156.  
  1157.   +FCR=n              Capability to receive parameter
  1158.  
  1159.            n=0        DCE will not receive message or poll a remote device
  1160.  
  1161.            n=1        DCE receives message data or polls a remote device
  1162.  
  1163.   +FCT=n              DTE phase C time-out parameter. n=0-255, 1 sec. units.
  1164.  
  1165.   +FDR                Receive phase C data command, initiates document
  1166.  
  1167.                       reception
  1168.  
  1169.   +FDT                Transmit phase C data command, releases the DCE to
  1170.  
  1171.                       proceed with negotiation
  1172.  
  1173.   +FEA=n              Phase C received EOL alignment parameter.
  1174.  
  1175.            n=0        Determine that T.4 EOL patterns are bit aligned (as
  1176.  
  1177.                       received).
  1178.  
  1179.            n=1        Determine that the last received bits of T.4 EOL
  1180.  
  1181.                       patterns are byte aligned by the DCE, with necessary
  1182.  
  1183.                       zero fill bits inserted.
  1184.  
  1185.   +FIE=n              Procedure interrupt parameter.
  1186.  
  1187.            n=0        Procedure interrupt requests from the remote station
  1188.  
  1189.                       are  ignored, and not reported to the DTE.
  1190.  
  1191.            n=1        Procedure interrupt requests from the remote station
  1192.  
  1193.                       are accepted, negotiated and reported using the +FVO
  1194.  
  1195.                       response.
  1196.  
  1197.   +FIP=n              Initialize facsimile parameters.
  1198.  
  1199.            n=0        (Or unspecified value) The parameters shall be set to
  1200.  
  1201.                       those specified in class 2.0.
  1202.  
  1203.   +FIS=vr,br,wd,ln,   Current session parameters. Refer to TIA-592 for
  1204.  
  1205.        df,ec,bf,st    details
  1206.  
  1207.   +FKS                Session termination command
  1208.  
  1209.   +FLI='string'       Local ID string parameter
  1210.  
  1211.   +FLO=n              Flow control options
  1212.  
  1213.            n=0        No flow control
  1214.  
  1215.            n=1        Set XON/XOFF software flow control
  1216.  
  1217.            n=2        Set CTS/RTS hardware flow control
  1218.  
  1219.   +FLP=n                     Document for polling command
  1220.  
  1221.            n=0        The DTE has no document for polling
  1222.  
  1223.            n=1        Indicate document available for polling
  1224.  
  1225.   +FMI?               Request DCE manufacturer identification.
  1226.  
  1227.   +FMM?               Request DCE model identification.
  1228.  
  1229.   +FMR?               Request DCE revision identification.
  1230.  
  1231.   +FMS=n              Minimum phase C speed parameter
  1232.  
  1233.            n=0        2400 bps
  1234.  
  1235.            n=1        4800 bps
  1236.  
  1237.            n=2        7200 bps
  1238.  
  1239.            n=3        9600 bps
  1240.  
  1241.            n=4        12000 bps
  1242.  
  1243.            n=5        14400 bps
  1244.  
  1245.   +FNR=rpr,tpr,idr,   Negotiation message reporting control parameters.
  1246.  
  1247.        nsr            Refer to TIA-592 for details.
  1248.  
  1249.   +FNS='string'       Non-standard byte string parameter.
  1250.  
  1251.                       'string': string of hexadecimal coded octets.
  1252.  
  1253.   +FPI='string'       Local fax station ID string, for polling Rx
  1254.  
  1255.   +FPP=n              Packet protocol control parameter.
  1256.  
  1257.            n=0        Disable the DCE-DTE packet protocol.
  1258.  
  1259.            n=1        Enable the DCE-DTE packet protocol. All the multi-
  1260.  
  1261.                       character messages from the DCE are sent to the DTE
  1262.  
  1263.                       using a simple packet protocol data link.
  1264.  
  1265.   +FPR=n              Serial port rate control parameter.
  1266.  
  1267.            n=0        Automatic DTE rate detection by the DCE.
  1268.  
  1269.            n>0        Serial rate is fixed at the value multiplied
  1270.  
  1271.                       by 2400 bps.
  1272.  
  1273.                       For example, n=8, DTE rate equal to 19,200 bps (8x2400)
  1274.  
  1275.   +FPS=n              Page transfer status
  1276.  
  1277.            n=1        Received page good
  1278.  
  1279.            n=2        Page bad, retrain requested
  1280.  
  1281.            n=3        Page good, retrain requested
  1282.  
  1283.            n=4        Page bad, procedure interrupt requested
  1284.  
  1285.            n=5        Page good, procedure interrupt requested
  1286.  
  1287.   +FRQ=pgl,cbl        Receive quality thresholds parameters. Refer to TIA-592
  1288.  
  1289.                       for details.
  1290.  
  1291.   +FRY=n              ECM retry value parameter. n=0-255, units of 4 retries.
  1292.  
  1293.   +FSP=n              Enable polling command
  1294.  
  1295.            n=0        Disable polling
  1296.  
  1297.            n=1        Enable polling
  1298.  
  1299.  
  1300.  
  1301.  
  1302.  
  1303.   FAX, FCLASS=1 'AT+F' COMMAND SET
  1304.  
  1305.   Command             Function & Description                             Ref.
  1306.  
  1307.  
  1308.  
  1309.   +<command>=<value>  Execute a command or set a parameter
  1310.  
  1311.   +<command>=?        Read permissible settings
  1312.  
  1313.   +<command>?         Read current setting
  1314.  
  1315.   +FCLASS=n           Service class selection
  1316.  
  1317.            n=0        Set to modem mode
  1318.  
  1319.            n=1        Set to Class 1 mode
  1320.  
  1321.            n=2        Set to Class 2 mode
  1322.  
  1323.            n=2.0      Set to Class 2.0 mode
  1324.  
  1325.            n=6        Set to ZFAX mode
  1326.  
  1327.            n=8        Set to Voice mode
  1328.  
  1329.            n=Z        Set to ZyXEL fax parallel port print and/or DRAM store
  1330.  
  1331.                       mode. (See also class Z 'AT+F' commands)
  1332.  
  1333.   +FTS=n              n=0-255. Stop transmission and pause, in 10 ms units.
  1334.  
  1335.   +FRS=n              n=0-255. Wait for silence, in 10 ms units.
  1336.  
  1337.   +FTM=<MOD>          Transmit data with <MOD> carrier.
  1338.  
  1339.   +FRM=<MOD>          Receive data with <MOD> carrier.
  1340.  
  1341.   +FTH=<MOD>          Transmit HDLC data with <MOD> carrier.
  1342.  
  1343.   +FRH=<MOD>          Receive HDLC data with <MOD> carrier.
  1344.  
  1345.                       The <MOD> parameter takes on the following values:
  1346.  
  1347.  
  1348.  
  1349.   Value   Modulation      Speed   Requirements
  1350.  
  1351.   3*      V.21 ch. 2      300     required for FTH & FRH
  1352.  
  1353.   24      V.27ter         2400    required for FTM & FRM
  1354.  
  1355.   48      V.27ter         4800    required for FTM & FRM
  1356.  
  1357.   72      V.29            7200    required for FTM & FRM
  1358.  
  1359.   73      V.17            7200    required for FTM & FRM
  1360.  
  1361.   74      V.17 w/st       7200    required for FTM & FRM
  1362.  
  1363.   96      V.29            9600    required for FTM & FRM
  1364.  
  1365.   97      V.17            9600    required for FTM & FRM
  1366.  
  1367.   98      V.17 w/st       9600    required for FTM & FRM
  1368.  
  1369.   121     V.17            12000   required for FTM & FRM
  1370.  
  1371.   122     V.17 w/st       12000   required for FTM & FRM
  1372.  
  1373.   145     V.17            14400   required for FTM & FRM
  1374.  
  1375.   146     V.17 w/st       14400   required for FTM & FRM
  1376.  
  1377.  
  1378.  
  1379.   * +FTH and +FRH support value 3 (V.21 ch. 2 / 300 bps) only
  1380.  
  1381.   w/st   with V.17 short training.
  1382.  
  1383.  
  1384.  
  1385.  
  1386.  
  1387.   FAX, FCLASS=6 'AT#' ENHANCED COMMAND SET
  1388.  
  1389.   Command             Function & Description                             Ref.
  1390.  
  1391.  
  1392.  
  1393.   #Bn                 'CONNECT FAX' result code enable or disable
  1394.  
  1395.            n=0        Disable, used in ZFAX mode, normal operation (*)
  1396.  
  1397.            n=1        Enabled, for BBS fax receiving application, this
  1398.  
  1399.                       command also changes 'CONNECT 12000/ARQ' to
  1400.  
  1401.                       'CONNECT 9600/ARQ'. This will also send out
  1402.  
  1403.                       external mail string 'ZyXEL' when fax is connected,
  1404.  
  1405.                       DCE will not send fax connection parameters
  1406.  
  1407.                       until <DC2> is received from DTE
  1408.  
  1409.            n=2        Enable Polling feature of Fax. Modem will send
  1410.  
  1411.                       polling signal to remote fax machine.
  1412.  
  1413.            n=3        Display ring cadence
  1414.  
  1415.            n=4        Disable Polling feature of Fax.
  1416.  
  1417.   #Cn                 Set minimun scan line time capability at the receiver
  1418.  
  1419.            n=0        20 ms at 3.85 line/mm, T(7.7)=T(3.85)
  1420.  
  1421.            n=1         5 ms at 3.85 line/mm, T(7.7)=T(3.85)
  1422.  
  1423.            n=2        10 ms at 3.85 line/mm, T(7.7)=T(3.85)
  1424.  
  1425.            n=3        20 ms at 3.85 line/mm, T(7.7)=1/2T(3.85)
  1426.  
  1427.            n=4        40 ms at 3.85 line/mm, T(7.7)=T(3.85)
  1428.  
  1429.            n=5        40 ms at 3.85 line/mm, T(7.7)=1/2T(3.85)
  1430.  
  1431.            n=6        10 ms at 3.85 line/mm, T(7.7)=1/2T(3.85)
  1432.  
  1433.            n=7         0 ms at 3.85 line/mm, T(7.7)=T(3.85)
  1434.  
  1435.   #En                 Display line conditions (if in On-Line state)
  1436.  
  1437.            n=0        Display mode off
  1438.  
  1439.            n=1        Display mode on
  1440.  
  1441.   #F                  Set the Modem into ZyXEL fax mode, same as AT&N32
  1442.  
  1443.   #H                  Display ISDN Country Code
  1444.  
  1445.   #Ln                 Set maximum recording length
  1446.  
  1447.            n=0        Set maximum recording length, A4 (297mm)
  1448.  
  1449.            n=1        Set maximum recording length, B4 (364mm)
  1450.  
  1451.            n=2        Set maximum recording length, unlimited.
  1452.  
  1453.   #P<string>          Set the local ID string, 25 characters max.
  1454.  
  1455.   #Rn                 Set recording width
  1456.  
  1457.            n=0        Set 1728 picture elements along a scan
  1458.  
  1459.                       line length of 215mm
  1460.  
  1461.            n=1        Set 2048 picture elements along a scan
  1462.  
  1463.                       line length of 255mm
  1464.  
  1465.            n=2        Set 2432 picture elements along a scan
  1466.  
  1467.                       line length of 303mm
  1468.  
  1469.   #Tn                 Coding Scheme
  1470.  
  1471.            n=0        Set to one dimensional coding scheme
  1472.  
  1473.            n=1        Set to two dimensional coding scheme
  1474.  
  1475.   #Vn                 Vertical resolution
  1476.  
  1477.            n=0        Set to normal vertical resolution
  1478.  
  1479.            n=1        Set to high vertical resolution
  1480.  
  1481.  
  1482.  
  1483.   Result Code (with #B0) 'CONNECT FAX/SnnnnVnTnRnLnCnP<string>'
  1484.  
  1485.               (with #B1) '/SnnnnVnTnRnLnCnP<string>'
  1486.  
  1487.                          'DISCONNECTxP<string>'
  1488.  
  1489.  
  1490.  
  1491.   Snnnn         First four digits of Fax connection speed
  1492.  
  1493.   Vn            Vertical resolution; n =0-1
  1494.  
  1495.   Tn            Coding scheme; n =0-1
  1496.  
  1497.   Rn            Recording width; n =0-2
  1498.  
  1499.   Ln            Recording length; n =0-2
  1500.  
  1501.   Cn            Scan time; n =0-7
  1502.  
  1503.   x             Disconnect with confirmation (x=0) or without (x=1)
  1504.  
  1505.   P<string>     Remote Fax number
  1506.  
  1507.   (*)           Manufacture default  (except when used  to represent
  1508.  
  1509.                 AT* commands)
  1510.  
  1511.  
  1512.  
  1513.  
  1514.  
  1515.   FAX, CLASS Z 'AT+F' COMMANDS
  1516.  
  1517.   Command             Function & Description                             Ref.
  1518.  
  1519.  
  1520.  
  1521.   +FZF=n              ZyXEL fax receive mode parallel port print/auto
  1522.  
  1523.                       data/DRAM store selection
  1524.  
  1525.            n=0  *     Fax to printer, hang up if data. (Default)
  1526.  
  1527.            n=1        Fax to printer, data to serial port.
  1528.  
  1529.            n=2        Fax to DRAM and printer, hang up if data.
  1530.  
  1531.            n=3        Fax to DRAM , hang up if data.
  1532.  
  1533.            n=4        Fax to DRAM and printer, data to serial port.
  1534.  
  1535.            n=5        Fax to DRAM, data to serial port.
  1536.  
  1537.   +FZL?               Show FAX receiving log
  1538.  
  1539.   +FZP                Print fax pages stored in DRAM if not printed yet
  1540.  
  1541.   +FZQ=n              Printing Qualitiy Control:
  1542.  
  1543.                       n=0  Fair quality with skipped line.
  1544.  
  1545.                       n=1  Fine qualitiy with no skipped line
  1546.  
  1547.   +FZT                Command to test your printer speed.
  1548.  
  1549.                       The modem will adjust scan line time
  1550.  
  1551.                       to fit your printer speed, and this
  1552.  
  1553.                       speed parameter will be saved in
  1554.  
  1555.                       non-volatile memory.
  1556.  
  1557.                       You don't have to issue 'AT+FZT'
  1558.  
  1559.                       command again when you turn on the
  1560.  
  1561.                       modem next time.
  1562.  
  1563.  
  1564.  
  1565.   +FZT=xxx            Set Fax Speed in Direct Fax Printing Mode.
  1566.  
  1567.  
  1568.  
  1569.                       +----------+-----------+-------------------+
  1570.  
  1571.                       |          |           |   Scanline Time   |
  1572.  
  1573.                       |FZT Value | Fax Speed |  Hi-Res   Low-Res |
  1574.  
  1575.                       +----------+-----------+---------+---------+
  1576.  
  1577.                       |   0- 15  |   14400   |    0ms  |    0ms  |
  1578.  
  1579.                       |  15- 31  |   14400   |    5ms  |   10ms  |
  1580.  
  1581.                       |  32- 47  |   14400   |   10ms  |   20ms  |
  1582.  
  1583.                       |  48- 63  |   14400   |   20ms  |   40ms  |
  1584.  
  1585.                       |  64- 95  |   14400   |   40ms  |   40ms  |
  1586.  
  1587.                       |  96-127  |    9600   |   40ms  |   40ms  |
  1588.  
  1589.                       | 128-195  |    4800   |   40ms  |   40ms  |
  1590.  
  1591.                       | 196-255  |    2400   |   40ms  |   40ms  |
  1592.  
  1593.                       +----------+-----------+---------+---------+
  1594.  
  1595.  
  1596.  
  1597.   +FZT=?              View current setting of Fax Speed in Direct
  1598.  
  1599.                       Fax Printing Mode.
  1600.  
  1601.   +FZX?               Command to show the captured log on terminal.   S76b0-2
  1602.  
  1603.                       This feature is not available for the FAX
  1604.  
  1605.                       direct printing mode.
  1606.  
  1607.  
  1608.  
  1609.  
  1610.  
  1611.   VOICE, FCLASS=8, 'AT+V' COMMAND SET
  1612.  
  1613.   Command             Function & Description                             Ref.
  1614.  
  1615.  
  1616.  
  1617.   <command>=<value>   Execute a command or set a parameter
  1618.  
  1619.   +<command>=?        Read permissible settings
  1620.  
  1621.   +<command>?         Read current setting
  1622.  
  1623.   +FCLASS=n           Service class selection
  1624.  
  1625.            n=0        Set to modem mode
  1626.  
  1627.            n=1        Set to Class 1 mode
  1628.  
  1629.            n=2        Set to Class 2 mode
  1630.  
  1631.            n=2.0      Set to Class 2.0 mode
  1632.  
  1633.            n=6        Set to ZFAX mode
  1634.  
  1635.            n=8        Set to Voice mode
  1636.  
  1637.            n=Z        Set to ZyXEL fax parallel port print and/or DRAM store
  1638.  
  1639.                       mode. (See also class Z 'AT+F' commands)
  1640.  
  1641.   +FLO=n              Flow control options
  1642.  
  1643.            n=0        No flow control
  1644.  
  1645.            n=1*       Set XON/XOFF software flow control
  1646.  
  1647.            n=2        Set CTS/RTS hardware flow control
  1648.  
  1649.   +VDD=<dds>,<ddi>    Set the DTMF tone detection sensitivity threshold and
  1650.  
  1651.                       the required period of continuous presence.
  1652.  
  1653.        <dds>=0-31     Set DTMF detection threshold. A lower value means the
  1654.  
  1655.              *15      DCE will detect DTMF tone more sensitively. A value of
  1656.  
  1657.                       '0' diasbles DTMF detection.
  1658.  
  1659.        <ddi>=0-255    Set the duration of DTMF tone detection, in units of
  1660.  
  1661.              *8       5 ms. The modem reports DTMF event when it detects a
  1662.  
  1663.                       continuous tone of at least this time interval. A value
  1664.  
  1665.                       of '0' diasbles DTMF detection.
  1666.  
  1667.   +VGR=n   n=56-200   Set the gain of received voice samples. Higher value
  1668.  
  1669.            *0         results in a larger gain (the normal value is 128). The
  1670.  
  1671.                       value of zero is for DCE automatic gain control.
  1672.  
  1673.   +VGT=n   n=56-200   Set the volume of playing voice. Higher value results
  1674.  
  1675.            *128       in a louder voice
  1676.  
  1677.   +VIP                The DCE initializes all voice parameters to their
  1678.  
  1679.                       default settings
  1680.  
  1681.   +VIT=n   n=0-255    Set the inactivity time-out timer value, in units of
  1682.  
  1683.            *70        0.1 second.
  1684.  
  1685.   +VLS=n              Voice I/O device selection
  1686.  
  1687.            n=0        DCE is on-hook. Disconnect all I/O devices (local phone
  1688.  
  1689.                       connects to telco line).
  1690.  
  1691.            n=1        Connects to local phone (PHONE jack). DCE is on-hook.
  1692.  
  1693.            n=2        DCE (modem) connects to telco line (Dial-up line jack).
  1694.  
  1695.                       DCE is off-hook.
  1696.  
  1697.            n=8        Connects to external mic.  (local phone connects to
  1698.  
  1699.                       telco line). DCE is on-hook.
  1700.  
  1701.            n=16       DCE connects to internal speaker (use modem's internal
  1702.  
  1703.                       speaker for voice playback, local phone connects to
  1704.  
  1705.                       telco line), DCE is on-hook.
  1706.  
  1707.   +VNH=n              Automatic hang-up options
  1708.  
  1709.            n=0*       DCE does not disable automatic hang-up
  1710.  
  1711.            n=1        DCE disables automatic hang-up usually found in other
  1712.  
  1713.                       non-voice modes.
  1714.  
  1715.            n=2        DCE disables automatic hang-up in other non-voice modes.
  1716.  
  1717.                       DCE only performs a 'logical' hang-up
  1718.  
  1719.                       (it will not really hang-up on an ATH command).
  1720.  
  1721.   +VRA=n   n=0-255    Set the length of time the DCE shall wait between
  1722.  
  1723.            *70        ringbacks before the DCE assumes remote station has
  1724.  
  1725.                       gone off-hook, in units of  0.1 second
  1726.  
  1727.   +VRN=n   n=0-255    Set the length of time the DCE shall wait while looking
  1728.  
  1729.            *60        for the first ringback before the DCE assumes remote
  1730.  
  1731.                       station has gone off-hook, in units of 0.1 second.
  1732.  
  1733.                       If the value of +VRN is larger than S7,  S7 will take
  1734.  
  1735.                       effect.
  1736.  
  1737.   +VRX                Start the voice reception process
  1738.  
  1739.   +VSD=<sds>,<sdi>    Set the silence detection sensitivity threshold and
  1740.  
  1741.                       the required period of silence
  1742.  
  1743.        <sds>=0-31     Larger value means the DCE treats noisier  conditions
  1744.  
  1745.              *15      as silence (the higher the value, the higher the
  1746.  
  1747.                       sensitivity threshold level). Set value '0' to disable
  1748.  
  1749.                       silence detection.
  1750.  
  1751.        <sdi>=0-255    In units of 0.1 second, required period of silence for
  1752.  
  1753.              *70      detection
  1754.  
  1755.   +VSM=n              Voice compression method selection
  1756.  
  1757.                       Four sampling rate : 7200, 8000, 9600, 11025 bps
  1758.  
  1759.                       Three digital compression algorithm : DVI ADPCM,
  1760.  
  1761.                       A-law PCM, Mu-law PCM.
  1762.  
  1763.            n=2 *      19.2 Kbps 2-bit ADPCM
  1764.  
  1765.            n=3        28.8 Kbps 3-bit ADPCM
  1766.  
  1767.            n=30       30.72 Kbps 3-bit ADPCM with resync capability
  1768.  
  1769.            n=4        38.4 Kbps 4-bit ADPCM
  1770.  
  1771.            n=40                 4-bit DVI ADPCM
  1772.  
  1773.            n=80                 8-bit A-law  PCM
  1774.  
  1775.            n=81                 8-bit Mu-law PCM
  1776.  
  1777.   +VSM=?              Show you how to use these features.
  1778.  
  1779.          For example, to set DVI ADPCM with 8000 sampling rate, you use the
  1780.  
  1781.          command:  AT+VSM=40,8000
  1782.  
  1783.          The power on default sampling rate is 2Bit ADPCM with 9600bps.
  1784.  
  1785.   +VSY=n   n=0-255    Set Voice recording resync timer, in units of 50 ms.
  1786.  
  1787.            *0         Set value '0' to disable resync generation
  1788.  
  1789.   +VTD=n   n=0-255    Set the DTMF tone generation duration used in
  1790.  
  1791.            *10        conjunction with +VTS command, in units of 10 ms
  1792.  
  1793.   +VTS=<string>       Cause the DCE to generate DTMF and other tones.
  1794.  
  1795.                       Refer to 2864 series user's manual for details.
  1796.  
  1797.   +VTX                Start the voice transmission process
  1798.  
  1799.   '*'     Manufacturer default (Except when used to represent 'AT*' commands)
  1800.  
  1801.   Snnnbx  Cross reference to S-register number 'nnn' bit number 'x'
  1802.  
  1803.  
  1804.  
  1805.  
  1806.  
  1807.   BASIC S-REGISTERS, 'ATSn=x'
  1808.  
  1809.   Command     Function & Description                               +Def./Ref.
  1810.  
  1811.  
  1812.  
  1813.   S0=         Set the number of rings on which the modem will
  1814.  
  1815.               answer.  0 value disable auto-answer                       +000
  1816.  
  1817.   S1=         Counts and stores number of rings from an
  1818.  
  1819.               incoming call                                              +000
  1820.  
  1821.   S2=         Define escape code character, default <+> (43
  1822.  
  1823.               dec.)                                                      +043
  1824.  
  1825.   S3=         Define ASCII Carriage Return                               +013
  1826.  
  1827.   S4=         Define ASCII Line Feed                                     +010
  1828.  
  1829.   S5=         Define ASCII Backspace                                     +008
  1830.  
  1831.   S7=         Set duration, in number of seconds, modem waits
  1832.  
  1833.               for a carrier                                              +060
  1834.  
  1835.   S8=         Set duration, in seconds, for pause (,) option in
  1836.  
  1837.               Dial command and pause between command
  1838.  
  1839.               re-executions for Repeat (>)command                        +002
  1840.  
  1841.   S9=         Set duration, in tenths of a second, of remote
  1842.  
  1843.               carrier signal before recognition (Ignored if in
  1844.  
  1845.               non-FSK or half-duplex operation)                          +006
  1846.  
  1847.   S10=        Set duration, in tenths of a second, modem waits
  1848.  
  1849.               after loss of carrier before hanging up                    +007
  1850.  
  1851.   S11=        Set duration and spacing, in milliseconds, of
  1852.  
  1853.               dialed Touch-Tones                                         +070
  1854.  
  1855.   S12=        Reserved
  1856.  
  1857.  
  1858.  
  1859.   EXTENDED S-REGISTERS, 'ATSn=x'
  1860.  
  1861.   Command         Function and description                         +Def./Ref.
  1862.  
  1863.  
  1864.  
  1865.   S13=    bit     dec     hex     Bit-mapped register                    +000
  1866.  
  1867.                                   (for internal fax/modem only)
  1868.  
  1869.           1       2       2       Capture modem manufacturer information
  1870.  
  1871.                                   during V.42 handshake, can be
  1872.  
  1873.                                   displayed at ATI2 <Last Speed/
  1874.  
  1875.                                   Protocol> line if available (Flash or
  1876.  
  1877.                                   ZyXEL stands for ZyXEL connection)
  1878.  
  1879.   S14=    bit     dec     hex     Bit-mapped register:                   +002
  1880.  
  1881.           0       0       0       Modem auto-handshake on Originate mode
  1882.  
  1883.                   1       1       Modem auto-handshake on Answer mode
  1884.  
  1885.   S15=    bit     dec     hex     Bit-mapped register                    +130
  1886.  
  1887.           0,1     0       0       Even parity
  1888.  
  1889.                   1       1       Odd parity
  1890.  
  1891.                   2       2  *    No parity
  1892.  
  1893.           2       0       0  *    1 stop bit
  1894.  
  1895.                   4       4       2 stop bits
  1896.  
  1897.           4,3     0       0  *    10 bit character length                 *C0
  1898.  
  1899.                   8       8       11 bit  *C1
  1900.  
  1901.                   16      10      9 bit   *C2
  1902.  
  1903.                   24      18      8 bit   *C3
  1904.  
  1905.           7-5     0       0       Profile 0 as active settings after
  1906.  
  1907.                                   power on                                 Z0
  1908.  
  1909.                   32      20      Profile 1 as active settings after
  1910.  
  1911.                                   power on                                 Z1
  1912.  
  1913.                   64      40      Profile 2 as active settings after
  1914.  
  1915.                                   power on                                 Z2
  1916.  
  1917.                   96      60      Profile 3 as active settings after
  1918.  
  1919.                                   power on                                 Z3
  1920.  
  1921.                   128     80 *    Factory default as active settings
  1922.  
  1923.                                   after power on                           Z4
  1924.  
  1925.   S16=    bit     dec     hex     Test status register                   +000
  1926.  
  1927.                   0       0       No test in progress                     &T0
  1928.  
  1929.                   For internal fax/modem only:
  1930.  
  1931.                   1       1       Loopback test in progress               &T1
  1932.  
  1933.                   8       8       Loopback with self test in progress     &T8
  1934.  
  1935.                   For ISDN data call only:
  1936.  
  1937.                   9       9       Loopback test in progress               &T9
  1938.  
  1939.                   10      A       Loopback with self test in progress    &T10
  1940.  
  1941.   S18=            dec             Force modem to fix baud rate when idle +000
  1942.  
  1943.                   0          *    Disable fixed baud function
  1944.  
  1945.                   n+1             Enable baud rate fixing at idle, n=0-15
  1946.  
  1947.                                   baud rate value settings (n) the
  1948.  
  1949.                                   same as S20 value
  1950.  
  1951.   S19=            dec     hex     Modem connection mode, same        +000/&Nn
  1952.  
  1953.                   0-73    0-49    setting value as 'AT&Nn' command
  1954.  
  1955.   S20=            dec     hex     DTE speed (bps).  Auto detected from
  1956.  
  1957.                                   AT command                             +003
  1958.  
  1959.                   0       0       230400
  1960.  
  1961.                   1       1       115200         dec     hex     DTE speed
  1962.  
  1963.                   2       2       76800          9         9        9600
  1964.  
  1965.                   3       3       57600          10        A        7200
  1966.  
  1967.                   4       4       38400          11        B        4800
  1968.  
  1969.                   5       5       19200          12        C        2400
  1970.  
  1971.                   6       6       16800          13        D        1200
  1972.  
  1973.                   7       7       14400          14        E        460800
  1974.  
  1975.                   8       8       12000          15        F        300
  1976.  
  1977.   S21=    bit     dec     hex     Bit mapped register                    +178
  1978.  
  1979.           0       0       0       Maintain non-error control connection   *E0
  1980.  
  1981.                                   when modem error control handshake fails
  1982.  
  1983.                   1       1       Drop connection when modem error        *E1
  1984.  
  1985.                                   control handshake fails
  1986.  
  1987.           1-2     0       0       Speaker always Off                       M0
  1988.  
  1989.                   2       2       Speaker On until carrier is detected     M1
  1990.  
  1991.                   4       4       Speaker always On                        M2
  1992.  
  1993.                   6       6       Speaker On after last digit is dialed    M3
  1994.  
  1995.                                   out until carrier detected
  1996.  
  1997.           3       0       0       DSR always On                           &S0
  1998.  
  1999.                   8       8       According to CCITT (see also S44b4,     &S1
  2000.  
  2001.                                   S41b5)
  2002.  
  2003.           4       0       0       CD always On                            &C0
  2004.  
  2005.                   16      10      CD tracks presence of data carrier      &C1
  2006.  
  2007.                                   (see also S38b3)
  2008.  
  2009.           6-7     0       0       Assume DTR always On                    &D0
  2010.  
  2011.                   64      40      108.1, DTR Off-On transition causes     &D1
  2012.  
  2013.                                   dial of the default number
  2014.  
  2015.                   128     80      108.2 Data Terminal Ready, DTR Off      &D2
  2016.  
  2017.                                   causes the modem to hang up and return
  2018.  
  2019.                                   to command state
  2020.  
  2021.                   192     C0      108.2, DTR off causes the modem to      &D3
  2022.  
  2023.                                   hang up and reset the modem to profile
  2024.  
  2025.                                   #0 after DTR dropped
  2026.  
  2027.   S23=    bit     dec     hex     Bit mapped register                    +105
  2028.  
  2029.           0       0       0       Command echo disabled                    E0
  2030.  
  2031.                   1       1       Command echo enabled                     E1
  2032.  
  2033.           2       0       0       Insertion is not allowed during a
  2034.  
  2035.                                   phone call
  2036.  
  2037.                   4       4       Insertion is allowed during a phone
  2038.  
  2039.                                   call
  2040.  
  2041.           3-5     0       0       ATX0  (See result code table)
  2042.  
  2043.                   8       8       ATX1            dec      hex      AT
  2044.  
  2045.                   16      10      ATX2            40        28       X5
  2046.  
  2047.                   24      18      ATX3            48        30       X6
  2048.  
  2049.                   32      20      ATX4            56        38       X7
  2050.  
  2051.           6       0       0       Display result code in numeric format    V0
  2052.  
  2053.                                   (see S35b7)
  2054.  
  2055.                   64      40      Display result code in verbose format    V1
  2056.  
  2057.           7       0       0       Modem returns result code                Q0
  2058.  
  2059.                   128     80      Modem does not return result code (see   Q1
  2060.  
  2061.                                   also S40b1)
  2062.  
  2063.   S24=    bit     dec     hex     Bit mapped register                    +138
  2064.  
  2065.           0-2     0-7     0-7     Ring volume control, increments of 1   N0-7
  2066.  
  2067.                                   in decimal
  2068.  
  2069.           4-6     16-112  10-70   0x10- 0x70  Speaker volume control,    L0-7
  2070.  
  2071.                                   increments of 16 in decimal value
  2072.  
  2073.   S27=    bit     dec     hex     Bit mapped register                    +156
  2074.  
  2075.           0-2                     For internal fax/modem:
  2076.  
  2077.                   0       0       No error control                        &K0
  2078.  
  2079.                   1       1       MNP4 + MNP3 (see also S41b0)            &K1
  2080.  
  2081.                   2       2       MNP4 + MNP5 (see also S38b5, S41b0)     &K2
  2082.  
  2083.                   3       3       V.42+MNP4                               &K3
  2084.  
  2085.                   4       4       V.42 + V.42bis (compatible with &K2)    &K4
  2086.  
  2087.           3-5     0       0       Flow control disabled                   &H0
  2088.  
  2089.                   24      18      Hardware (RTS/CTS) flow control         &H3
  2090.  
  2091.                   32      20      Software (XON/XOFF) flow control        &H4
  2092.  
  2093.                   40      28      Reserved                                &H5
  2094.  
  2095.           6-7                     For internal fax/modem:
  2096.  
  2097.                   0       0       No response to poor signal quality      *Q0
  2098.  
  2099.                   64      40      Retrain action taken if signal quality  *Q1
  2100.  
  2101.                                   is poor
  2102.  
  2103.                   128     80      Adaptive rate (auto fall-back /         *Q2
  2104.  
  2105.                                   forward) when signal quality changes  S41b2
  2106.  
  2107.                   192     C0      Disconnect when signal quality is poor  *Q3
  2108.  
  2109.   S28=    bit     dec     hex     Bit mapped register                    +068
  2110.  
  2111.           0                       reserved
  2112.  
  2113.           4-5     0       0       No guard tone                           &G0
  2114.  
  2115.                   16      10      Reserved                                &G1
  2116.  
  2117.                   32      20      1800 Hz guard tone                      &G2
  2118.  
  2119.           7       0       0  *    Select V.22 for 1200 bps communication
  2120.  
  2121.                   128     80      Select Bell 212A for 1200 bps
  2122.  
  2123.                                   communication
  2124.  
  2125.   S29=            0-39    0-39    Set default dial phone number pointer, +000
  2126.  
  2127.                                   use AT&Zn=s to store phone numbers       *D
  2128.  
  2129.   S31=            0-255    0-FF   Holds the ASCII decimal value of the   +017
  2130.  
  2131.                                   XON
  2132.  
  2133.   S32=            0-255    0-FF   Holds the ASCII decimal value of the   +019
  2134.  
  2135.                                   XOFF
  2136.  
  2137.   S35=    bit     dec     hex     Bit mapped register                    +000
  2138.  
  2139.           1       2       2       Disable aborting from connection during
  2140.  
  2141.                                   modem handshaking
  2142.  
  2143.           4       16      10      When Data/Voice switch is pushed,   *Dn S29
  2144.  
  2145.                                   modem will dial the default number
  2146.  
  2147.           5       32      20      SREJ option: Enable Selective Reject
  2148.  
  2149.                                   in V.42 (Default)
  2150.  
  2151.           7       128     60      Enable extended numerical result codes   V0
  2152.  
  2153.                                   from 50-71 when an error correction   S23b6
  2154.  
  2155.                                   connection is made, use with ATV0, see
  2156.  
  2157.                                   result code table
  2158.  
  2159.   S36=    bit     dec     hex     Bit mapped register                    +000
  2160.  
  2161.           5-7                     Security function control register
  2162.  
  2163.                                   *G3,*G4,*G5 for both ISDN and Modem call
  2164.  
  2165.                  *0       0       Disable security function               *G0
  2166.  
  2167.                   32      20      Enable type 1 security, with password   *G1
  2168.  
  2169.                                   check (ZyXEL to ZyXEL only)
  2170.  
  2171.                   64      40      Enable type 1 security, with password   *G2
  2172.  
  2173.                                   check and call-back (ZyXEL to ZyXEL
  2174.  
  2175.                                   only)
  2176.  
  2177.                   96      60      Enable type 2 security, with password   *G3
  2178.  
  2179.                                   check
  2180.  
  2181.                   128     80      Enable type 2 security, with password   *G4
  2182.  
  2183.                                   check and call-back
  2184.  
  2185.                   160     A0      Enable type 2 security, with password   *G5
  2186.  
  2187.                                   check and call-back, remote site enter
  2188.  
  2189.                                   the call-back number
  2190.  
  2191.   S38=    bit     dec     hex     Bit mapped register                    +000
  2192.  
  2193.           0       1       1       Repeatedly dialing default number   *Dn S29
  2194.  
  2195.           3       8       8       DCD on/off sequence follows UNIX  &C1 S21b4
  2196.  
  2197.                                   standard, DCD high before connect
  2198.  
  2199.                                   message is sent, DCD off after last
  2200.  
  2201.                                   DCE response is sent
  2202.  
  2203.           4       16      10      Auto-mode fax receiving disabled        &N0
  2204.  
  2205.           5       32      20      Disable MNP5                            &Kn
  2206.  
  2207.   S39=    bit     dec     hex     Bit mapped register                    +000
  2208.  
  2209.                                   (for internal fax/modem only)
  2210.  
  2211.           2       4       4       Answer in originating mode              ATA
  2212.  
  2213.           3       8       8       Class 2 Fax Bitfax compatibility:
  2214.  
  2215.                                   +FCON at 2400 next phase at 19200
  2216.  
  2217.           4       16      10      Class 2 Fax mode DTE shifting:
  2218.  
  2219.                                   +FCON at current DTE, shift to 19,200
  2220.  
  2221.                                   when entering into the next phase
  2222.  
  2223.   S40=    bit     dec     hex     Bit mapped register                    +000
  2224.  
  2225.           1       2       2       No result code displayed in answer       Q2
  2226.  
  2227.                                   mode
  2228.  
  2229.   S41=    bit     dec     hex     Bit mapped register                    +000
  2230.  
  2231.                                   For internal fax/modem:
  2232.  
  2233.           0       1       1       Special MNP compatibility (see also     &Kn
  2234.  
  2235.                                   S27b0, S38b5)
  2236.  
  2237.           2       4       4       Disable retrain abort, up to 5 min.   S27b6
  2238.  
  2239.                                   for special satellite line condition    *Qn
  2240.  
  2241.  
  2242.  
  2243.           3       8       8       Enable CCITT signals 140 and 141 on
  2244.  
  2245.                                   EIA-232D interface
  2246.  
  2247.           4       16      10      In X2-X7 setting, modem waits for S6
  2248.  
  2249.                                   seconds before dialing and ignores
  2250.  
  2251.                                   dial tone detection
  2252.  
  2253.           5       32      20      DSR follows DCD and pulses (see also    &Sn
  2254.  
  2255.                                   S44b4)
  2256.  
  2257.           6       64      40      Force S0>=2                              S0
  2258.  
  2259.           7       128     80      Ignore calling tone, not to be used as
  2260.  
  2261.                                   fax detection
  2262.  
  2263.   S42=    bit     dec     hex     Bit mapped register                    +000
  2264.  
  2265.           3       8       8       Disable escape sequence code in answer
  2266.  
  2267.                                   mode
  2268.  
  2269.           4       16      10      Disable V.17, 14,400 Fax in calling
  2270.  
  2271.                                   mode, no effect to answering mode &N32
  2272.  
  2273.           5       32      20      Disable Data/Voice button
  2274.  
  2275.           6       64      40      Disable <RINGING> result code            Xn
  2276.  
  2277.           7       128     80      DCD forced on but pulse off for 0.5     &C0
  2278.  
  2279.                                   seconds at carrier loss
  2280.  
  2281.   S43=    bit     dec     hex     Bit mapped register                    +000
  2282.  
  2283.           0       1       1       Disable ZyXEL 16800 in Multi-Auto mode  &N0
  2284.  
  2285.           1       2       2       Disable ZyXEL 19200 in Multi-Auto mode
  2286.  
  2287.   S44=    bit     dec     hex     Bit mapped register                    +000
  2288.  
  2289.           3       8       8       ATDSn initiates auto-dial of the        &Zn
  2290.  
  2291.                                   stored numbers consecutively until a  S38b0
  2292.  
  2293.                                   connection is made
  2294.  
  2295.           4       16      10      DSR follows DTR (see also S41b5)        &Sn
  2296.  
  2297.   S48=    bit  dec  hex           Bit-mapped register                    +000
  2298.  
  2299.           2    4    4             Enable data CNG calling tone transmission
  2300.  
  2301.   S50=    0-255                   Inactivity timer for RS 232 port       +000
  2302.  
  2303.                                   this timer counts when there is no data
  2304.  
  2305.                                   flow in or out of the RS 232 serial port;
  2306.  
  2307.                                   modem will hang up phone, when timed out.
  2308.  
  2309.                                   units is 10 seconds! 000 disables timer
  2310.  
  2311.                 note: timer is forced disabled in leased line and ISDN Mode
  2312.  
  2313.  
  2314.  
  2315.   S56=            dec     hex     Hook flash detected time for a/b       +050
  2316.  
  2317.                   0-255   0-FF    adapter, in units of 10ms
  2318.  
  2319.   S57=    bit     dec     hex
  2320.  
  2321.           0-3                     Reserved
  2322.  
  2323.           4       16      10      Enables the reporting of Class 1 capability
  2324.  
  2325.                                   in the response to +FCLASS=?
  2326.  
  2327.           5                       Reserved
  2328.  
  2329.           6       64      40      Enables busy detection in dialing period
  2330.  
  2331.           7       128     80      Report 'DATA or FAX' before showing
  2332.  
  2333.                                   Connect Message
  2334.  
  2335.   S66=n                   *0      Dial back repeat counter of security
  2336.  
  2337.                                   function
  2338.  
  2339.   S70=        Reserved, Read only, do not alter the value                +00
  2340.  
  2341.   S71=    bit     dec     hex     Bit-mapped register:                   +064
  2342.  
  2343.           0-2     0-5     0-5     ZyXEL fax receive mode select          +FZF
  2344.  
  2345.                  *0       0       Fax to printer, hang up if data
  2346.  
  2347.                   1       1       Fax to printer, data to serial port
  2348.  
  2349.                   2       2       Fax to DRAM & printer, hang up if data
  2350.  
  2351.                   3       3       Fax to DRAM, hang up if data
  2352.  
  2353.                   4       4       Fax to DRAM & printer, data to serial port
  2354.  
  2355.                   5       5       Fax to DRAM, data to serial port
  2356.  
  2357.           4       16      10      Delete DRAM fax file after printed
  2358.  
  2359.           5       32      20      Keep DRAM fax even it has been retrieved
  2360.  
  2361.           6      *0       0       High speed fax retrieval for ZFAX only
  2362.  
  2363.                   64      40      Slow retrieve process (for Class 2)
  2364.  
  2365.   S72=            dec     hex     Select printer type                    +000
  2366.  
  2367.                  *0       0       HP LJ-II series or compitable PCL Printer
  2368.  
  2369.                   1       1       HP LJ-III series or compitable PCL Printer
  2370.  
  2371.                   2       2       POSTSCRIPT Printer
  2372.  
  2373.   S73=    bit     dec     hex     Bit-mapped register:                   +008
  2374.  
  2375.           0      *0       0       Parallel Port for fax printing
  2376.  
  2377.                   1       1       Serial Port for fax printing
  2378.  
  2379.           1      *0       0       Fast PCL Printing
  2380.  
  2381.           2      *0       0       PCL printing resolution 300dpi         +FZR
  2382.  
  2383.                   4       4       PCL printing resolution 150dpi
  2384.  
  2385.           3      *8       8       Automatic resize for fax printing
  2386.  
  2387.           4-5     0-32    0-20    ZyXEL fax printing, paper size         +FZS
  2388.  
  2389.                   0       0       Paper size : LETTER (8.5 inch * 11 inch)
  2390.  
  2391.                   16      10      Paper size : LEGAL (8 inch * 14 inch)
  2392.  
  2393.                   32      20      Paper size : A4 (210 mm * 287 mm)
  2394.  
  2395.   S74=        Reserved, Read only, do not alter the value                +00
  2396.  
  2397.   S75=    bit     dec     hex     Bit-mapped register:                   +008
  2398.  
  2399.           0-2     0-5     0-5     Multiauto answered fax class selection
  2400.  
  2401.                   0       0       Auto answer by fax class 2
  2402.  
  2403.                   1       1       Auto answer by fax class 2.0
  2404.  
  2405.                   2       2       Auto answer by fax class 6 / ZFAX
  2406.  
  2407.                   3       3       Auto answer by fax class 1
  2408.  
  2409.                   4       4       Auto answer by fax class Z / DRAM
  2410.  
  2411.                   5       5       Auto answer by fax class Z / Printer
  2412.  
  2413.   S76=    bit     dec     hex     Bit mapped register                    +000
  2414.  
  2415.           0       1       1       FAX response capture enabled
  2416.  
  2417.           1       2       2       FAX command capture enabled
  2418.  
  2419.           2       4       4       V.21 HDLC Tx/Rx capture enabled
  2420.  
  2421.                                   This feature is not available for the FAX
  2422.  
  2423.                                   direct printing mode.
  2424.  
  2425.     Use 'AT+FZX?' command to show the captured log on terminal.
  2426.  
  2427.  
  2428.  
  2429.   S79=    bit     dec     hex     Bit-mapped register:                   +000
  2430.  
  2431.           7      *0       0       Sending RELEASE COMPLETE with cause 'call
  2432.  
  2433.                                   reject' for ATH1
  2434.  
  2435.                   128     80      Sending RELEASE COMPLETE with cause 'user
  2436.  
  2437.                                   busy' for ATH1
  2438.  
  2439.   S80=    bit     dec     hex     Bit-mapped register:                   +000
  2440.  
  2441.           4      *0       0       Not sending Low Layer Compatibility
  2442.  
  2443.                                   information for internal fax/modem
  2444.  
  2445.                   16      10      Sending Low Layer Compatibility
  2446.  
  2447.                                   for internal fax/modem
  2448.  
  2449.           6      *0       0       Not sending Low Layer Compatibility
  2450.  
  2451.                                   information for ISDN data call
  2452.  
  2453.                   64      40      Sending Low Layer Compatibility
  2454.  
  2455.                                   for ISDN data call
  2456.  
  2457.           7      *0       0       Not sending Low Layer Compatibility
  2458.  
  2459.                                   information for a/b adapter
  2460.  
  2461.                   128     80      Sending Low Layer Compatibility
  2462.  
  2463.                                   for a/b adapter
  2464.  
  2465.   S82=                            ISDN B channel protocol                  Bn
  2466.  
  2467.                   60              V.120 64000
  2468.  
  2469.                   61              V.120 56000
  2470.  
  2471.                   62              X.75  64000 Transparent
  2472.  
  2473.                   63              X.75  56000 Transparent
  2474.  
  2475.                   64              X.75  64000 T.70
  2476.  
  2477.                   65              X.75  56000 T.70
  2478.  
  2479.                   70              X.75  64000 BTX
  2480.  
  2481.                   71              X.75  56000 BTX
  2482.  
  2483.                   72              V.110 64000
  2484.  
  2485.                   73              V.110 56000
  2486.  
  2487.                   74              PPP async to sync 64K
  2488.  
  2489.                   75              PPP async to sync 56K
  2490.  
  2491.                   76              SLIP to sync HDLC conversion 64K
  2492.  
  2493.                   77              SLIP to sync HDLC conversion 56K
  2494.  
  2495.   S83=    bit     dec     hex     Bit-mapped register:                   +000
  2496.  
  2497.           0       0       0       Disable loopback 4 test                 CP0
  2498.  
  2499.                   1       1       Enable loopback 4 test                  CP1
  2500.  
  2501.           2       0       0       ISDN without V.42bis                   &K00
  2502.  
  2503.                   4       4       ISDN with V.42bis if applicable        &K44
  2504.  
  2505.           4-5     0       0  *    ATDs, ATDPs, and ATDTs is mapped        &O0
  2506.  
  2507.                                   to ATDMs
  2508.  
  2509.                   32      20      ATDs, ATDPs, and ATDTs is mapped        &O2
  2510.  
  2511.                                   to ATDIs
  2512.  
  2513.                   48      30      ATDs, ATDPs, and ATDTs is mapped        &O3
  2514.  
  2515.                                   to ATDBs
  2516.  
  2517.           6       0       0  *    DOVBS answer using 56Kbps (for USA only)
  2518.  
  2519.                   64      40      DOVBS answer using 64Kbps
  2520.  
  2521.           7       0       0  *    ISDN data call using nornal Bearer Service
  2522.  
  2523.                                   (for USA only)
  2524.  
  2525.                   128     80      ISDN data call using voice Bearer Service
  2526.  
  2527.   S84=    bit     dec     hex
  2528.  
  2529.           0-2                     Embedded protocol analyzer control      CCn
  2530.  
  2531.           0       1       1       Capture DTE-DCE interface protocol
  2532.  
  2533.                                   information
  2534.  
  2535.           1       2       2       Capture the B-channel (X.75 or V.120)
  2536.  
  2537.                                   frames
  2538.  
  2539.           2       4       4       Capture the D-channel protocol
  2540.  
  2541.                                   information
  2542.  
  2543.           3       0      *0       Display S register value in decimal
  2544.  
  2545.                                   format
  2546.  
  2547.                   8       8       Display S register value in hex format
  2548.  
  2549.           4      *0       0       Indicate Caller ID after the 1st RING
  2550.  
  2551.                                   message
  2552.  
  2553.                   16      10      Disable Caller ID indication
  2554.  
  2555.           5       0       0       Ambiguity resolution bit, A/B adaptor   &L0
  2556.  
  2557.                                   first
  2558.  
  2559.                   32      20      Ambiguity resolution bit, Fax/Modem     &L1
  2560.  
  2561.                                   first
  2562.  
  2563.   S85=    bit     dec     hex
  2564.  
  2565.           0       0       0       Call Bumping function disabled          CE0
  2566.  
  2567.                   1      *1       Call Bumping function enabled           CE1
  2568.  
  2569.           1-6            *0       Add-persist time interval              KAxn
  2570.  
  2571.           7       0      *0       S85b1-6 is in Second unit              KASn
  2572.  
  2573.                   128     80      S85b1-6 is in Minute unit              KAMn
  2574.  
  2575.   S86=            dec     hex     D-channel protocol selection(USA)        Pn
  2576.  
  2577.                                   The following number is valid for
  2578.  
  2579.                                   American version:
  2580.  
  2581.                   0       0       Northern Telecom proprietary ISDN
  2582.  
  2583.                   1       1       National ISDN 1 (1 SPID mode)
  2584.  
  2585.                   2       2       National ISDN 1 (2 SPIDs mode)
  2586.  
  2587.                   3       3       reserved
  2588.  
  2589.                   4       4       AT&T proprietary point-to-point
  2590.  
  2591.                   5       5       AT&T proprietary point-to-multipoint
  2592.  
  2593.                                   (1 SPID mode)
  2594.  
  2595.                   6       6       AT&T proprietary point-to-multipoint
  2596.  
  2597.                                   (2 SPIDs mode)
  2598.  
  2599.                                   All other values are reserved.
  2600.  
  2601.   S87=    bit     dec     hex
  2602.  
  2603.           2       0       0       CHAP/PAP for authentication conversion
  2604.  
  2605.                   4       4       PAP only for authentication conversion
  2606.  
  2607.           4      *0       0       result code 46 for X7 is CONNECT 112K/......
  2608.  
  2609.                                   result code 47 for X7 is CONNECT 128K/......
  2610.  
  2611.                   16      10      result code 46 for X7 is CONNECT 112000/....
  2612.  
  2613.                                   result code 47 for X7 is CONNECT 128000/....
  2614.  
  2615.           5-6    *0       0       Bundle connection is disabled           &Jn
  2616.  
  2617.                   32      20      Bundle connection is enabled in answer
  2618.  
  2619.                                   mode only
  2620.  
  2621.                   64      40      Bundle connection is enabled in call
  2622.  
  2623.                                   mode only
  2624.  
  2625.                   96      60      Bundle connection is enabled in both
  2626.  
  2627.                                   directions
  2628.  
  2629.  
  2630.  
  2631.   S89=    bit     dec     hex     Bundle and data encryption control
  2632.  
  2633.           0      *0       0       DES disabled
  2634.  
  2635.                   1       1       DES preferred
  2636.  
  2637.           1      *0       0       Single DES is alright
  2638.  
  2639.                   2       2       Triple DES is preferred
  2640.  
  2641.           2      *0       0       PKDS on, key automatically generated
  2642.  
  2643.                   4       4       no PKDS, keyin the key words
  2644.  
  2645.           3      *0       0       Keep connection whether there is DES or not
  2646.  
  2647.                   8       8       Disconnect the call if DES link cannot be
  2648.  
  2649.                                   established
  2650.  
  2651.           4      *0       0       second voice call will be routed to a/b
  2652.  
  2653.                                   adaptor if &L1 is set
  2654.  
  2655.                   16      10      second voice call won't be routed to a/b
  2656.  
  2657.                                   adaptor if &L1 is set
  2658.  
  2659.           6      *0       0       disable the metering pulse
  2660.  
  2661.                   64      40      enable the metering pulse
  2662.  
  2663.   S100            dec     hex     B channel bundling protocol selection
  2664.  
  2665.                   0       0     * Multiple Link Protocol (MLP)
  2666.  
  2667.                   1       1       cFossil channel bundling (CCB)
  2668.  
  2669.                                   (not supported for American version)
  2670.  
  2671.  
  2672.  
  2673.   S102=   bit     dec     hex     Outgoing ISDN data type                 Bnn
  2674.  
  2675.                                   Value has the same definition as S82
  2676.  
  2677.   S103=                           Set number of RING to the a/b adapter
  2678.  
  2679.                   0               The call sent to the a/b adapter will
  2680.  
  2681.                                   keep ringing until the call is answered
  2682.  
  2683.                                   or the calling side on-hook.
  2684.  
  2685.                   n>0             When the RING count has reached the value
  2686.  
  2687.                                   set (n), the a/b adapter analog call will
  2688.  
  2689.                                   be re-routed to internal fax/modem
  2690.  
  2691.   S104+n=         dec     hex     Outgoing Service Indicator (for 1TR6 only)
  2692.  
  2693.                                   n = 0(internal fax/modem), 2(ISDN data),
  2694.  
  2695.                                       or 3(a/b adapter)
  2696.  
  2697.                   1       1       Fernsprechen
  2698.  
  2699.                   2       2       a/b - Dienste
  2700.  
  2701.                   7       7       Datenübertragung 64 kbps. The defaults
  2702.  
  2703.                                   are :
  2704.  
  2705.                                   2 - internal fax/modem
  2706.  
  2707.                                   7 - ISDN data
  2708.  
  2709.                                   1 - a/b adaptor)
  2710.  
  2711.   S108+n=         dec     hex     Outgoing Service Additional (for 1TR6 only)
  2712.  
  2713.                                   Information
  2714.  
  2715.                                   n = 0(internal fax/modem), 2(ISDN data),
  2716.  
  2717.                                       or 3(a/b adapter)
  2718.  
  2719.           SI=1    1       1       ISDN-Fernsprechen 3.1 kHz
  2720.  
  2721.                   2       2       Fernsprechen analog
  2722.  
  2723.           SI=2    2       2       Fax Gruppe 3
  2724.  
  2725.                   3       3     * Daten über Modem
  2726.  
  2727.                   4       4       Btx über Modem
  2728.  
  2729.           SI=7    0       0       Datenübertragung 64 kbps (X.75 SLP)
  2730.  
  2731.                   11------        Async V.110
  2732.  
  2733.                   01------        Extensions of async
  2734.  
  2735.                   --0-----      * Number of data bits : 8
  2736.  
  2737.                   --1-----        Number of data bits : 7
  2738.  
  2739.                   ---0----      * Number of stop bits : 1
  2740.  
  2741.                   ---1----        Number of stop bits : 2
  2742.  
  2743.                   ----0---      * No parity
  2744.  
  2745.                   ----1---        Even parity
  2746.  
  2747.                   11---000        1200 bps
  2748.  
  2749.                   11---011        2400 bps
  2750.  
  2751.                   11---100        4800 bps
  2752.  
  2753.                   11---101        9600 bps
  2754.  
  2755.                   11---110        14400 bps
  2756.  
  2757.                   11---111      * 19200 bps
  2758.  
  2759.                   01---000        38400 bps
  2760.  
  2761.                   1010----        Sync V.110
  2762.  
  2763.                   10100000        1200 bps
  2764.  
  2765.                   10100011        2400 bps
  2766.  
  2767.                   10100100        4800 bps
  2768.  
  2769.                   10100101        9600 bps
  2770.  
  2771.                   10100110        14400 bps
  2772.  
  2773.                   10100111        19200 bps
  2774.  
  2775.                   10101000        48000 bps
  2776.  
  2777.                   10101001        56000 bps
  2778.  
  2779.                   10101010        56000 bps for 56kbit-network
  2780.  
  2781.                   10101111        In band negotiation
  2782.  
  2783.   S108+n=         dec     hex     High Layer Compatibility (Non-1TR6)
  2784.  
  2785.                                   n = 0(internal fax/modem), 2(ISDN data),
  2786.  
  2787.                                       or 3(a/b adapter)
  2788.  
  2789.                  *0       0       No High-Layer-Compatibility
  2790.  
  2791.                                   information element will be sent
  2792.  
  2793.                   1       1       Telephone
  2794.  
  2795.                   4       4       Facsimile Group 2/3
  2796.  
  2797.                   40      28      Teletex service(Rec.F.220)
  2798.  
  2799.                   49      31      Teletex service(Rec.F.200)
  2800.  
  2801.                   50      32      Information interworking for
  2802.  
  2803.                                   video services(Rec.F.300 T.110)
  2804.  
  2805.                   53      35      Telex service(Rec.F.60)
  2806.  
  2807.                   56      38      Message Handling Syxtems(MHS)
  2808.  
  2809.                                   (Rec.X.400 series)
  2810.  
  2811.                   65      41      OSI application(Rec.X.200 series)
  2812.  
  2813.   S114=                           I-field data length (MSB byte)
  2814.  
  2815.   S115=                           I-field data length (LSB byte)
  2816.  
  2817.   S117=                           V.110 user rate                    B1n
  2818.  
  2819.   S118=   bit     dec     hex
  2820.  
  2821.           0      *0       0       Enable  dial-in call
  2822.  
  2823.                   1       1       Disable dial-in call(dial out only)
  2824.  
  2825.           3      *0       0       Disable CHAP option for PPP/MLPPP
  2826.  
  2827.                   8       8       Enable CHAP option for PPP/MLPPP
  2828.  
  2829.           4      *0       0       Use 3.1KHz Bearer service whenever
  2830.  
  2831.                                   possible for internal fax/modem
  2832.  
  2833.                   16      10      Use Speech Bearer service whenever
  2834.  
  2835.                                   possible for internal fax/modem
  2836.  
  2837.           5      *0       0       Use 3.1KHz Bearer service whenever
  2838.  
  2839.                                   possible for a/b adapter
  2840.  
  2841.                   32      20      Use Speech Bearer service whenever
  2842.  
  2843.                                   possible for a/b adapter
  2844.  
  2845.           6      *0       0       Enable the a/b adapter to accept global
  2846.  
  2847.                                   calls
  2848.  
  2849.                   64      40      Forbid the a/b adapter to accept incoming
  2850.  
  2851.                                   calls with MSN unmatched (including global
  2852.  
  2853.                                   calls, see AT&ZI=s)
  2854.  
  2855.           7      *0       0       Enable analog incoming calls
  2856.  
  2857.                   128     80      Reject analog incoming calls (pure ISDN data)
  2858.  
  2859.   S119=   bit     dec     hex
  2860.  
  2861.           0      *0       0       Disable call-back function(see AT*GC)
  2862.  
  2863.                   1       1       Enable call-back function
  2864.  
  2865.           1      *0       0       Disable point-to-point signaling DDI function
  2866.  
  2867.                   2       2       Enable point-to-point signaling DDI function
  2868.  
  2869.           2      *0       0       Disable point-to-multipoint signaling DDI
  2870.  
  2871.                                   function
  2872.  
  2873.                   4       4       Enable point-to-multipoint signaling DDI
  2874.  
  2875.                                   function
  2876.  
  2877.           3      *0       0       when no MSN(EAZ) is matched, the inbound
  2878.  
  2879.                                   call will be ignored
  2880.  
  2881.                   8       8       when no MSN(EAZ) is matched, enter multi-
  2882.  
  2883.                                   auto mode to detect protocol
  2884.  
  2885.           4       0       0       V.110 user rate = 19200 bps if DTE speed
  2886.  
  2887.                                   greater 19200 bps
  2888.  
  2889.                  *16      10      V.110 user rate = 38400 bps if DTE speed
  2890.  
  2891.                                   greater 38400 bps
  2892.  
  2893.           5      *0       0       enable normal MSN function              &ZIn=
  2894.  
  2895.                   32      20      treat the number assigned by &ZIn=xx..
  2896.  
  2897.                                   as subaddress and matches with the called
  2898.  
  2899.                                   party subaddress for inbound call routing
  2900.  
  2901.   S120=                           Accumulated charging unit (MSB byte) for B1
  2902.  
  2903.                                   channel
  2904.  
  2905.   S121=                           Accumulated charging unit (LSB byte) for B1
  2906.  
  2907.                                   channel
  2908.  
  2909.   S122=                           Accumulated charging unit (MSB byte) for B2
  2910.  
  2911.                                   channel
  2912.  
  2913.   S123=                           accumulated charging unit (LSB byte) for B2
  2914.  
  2915.                                   channel
  2916.  
  2917.   S124=           dec     hex     Empty IP packet interval for PPP       +000
  2918.  
  2919.                   0-255   0-FF    in units of 1s
  2920.  
  2921.   S125=   bit     dec     hex
  2922.  
  2923.           1-6            *0       Sub-persist time interval              KSxn
  2924.  
  2925.           7       0      *0       S125b1-6 is in Second unit             KSSn
  2926.  
  2927.                   128     80      S125b1-6 is in Minute unit             KSMn
  2928.  
  2929.   S126=           dec     hex     Add-threshold for BOD               JAn,+48
  2930.  
  2931.                   0-255   0-FF    in Kbps unit
  2932.  
  2933.   S127=           dec     hex     Sub-threshold for BOD               JSn,+32
  2934.  
  2935.                   0-255   0-FF    in Kbps unit
  2936.  
  2937.  
  2938.  
  2939.   In 'Reference' column, 'AT' is omitted when AT command is referred to.
  2940.  
  2941.   +nnn is manufacturer default when listed in 'Reference' column.
  2942.  
  2943.   bit     S-register bit number, 'b',  used in 'ATSr.b=n', 'ATSr.b=?'
  2944.  
  2945.   dec     Decimal value, 'x', used in 'ATSn=x'
  2946.  
  2947.   hex     Hex value, used in LCD model for setting 'STATUS REGISTER'
  2948.  
  2949.           manually from front panel
  2950.  
  2951.  
  2952.  
  2953.   RESULT CODE OPTIONS TABLE
  2954.  
  2955.  
  2956.  
  2957.   ATV0    ATV1            ATX0  X1   X2   X3   X4   X5   X6   X7
  2958.  
  2959.     0     OK               V    V    V    V    V    V    V    V
  2960.  
  2961.     1     CONNECT          V    V    V    V    V    @    $    #
  2962.  
  2963.     2     RING             V    V    V    V    V    V    V    V
  2964.  
  2965.     3     NO CARRIER       V    V    V    V    V    V    V    V
  2966.  
  2967.     4     ERROR            V    V    V    V    V    V    V    V
  2968.  
  2969.     5     CONNECT 1200          %    %    %    %    @    $    #
  2970.  
  2971.     6     NO DIAL TONE               V         V    V    V    V
  2972.  
  2973.     7     BUSY                            V    V    V    V    V
  2974.  
  2975.     8     NO ANSWER                       V    V    V    V    V
  2976.  
  2977.     9     RINGING*                        V    V    V    V    V
  2978.  
  2979.     10    CONNECT 2400          %    %    %    %    @    $    #
  2980.  
  2981.     11    CONNECT 4800          %    %    %    %    @    $    #
  2982.  
  2983.     12    CONNECT 9600          %    %    %    %    @    $    #
  2984.  
  2985.     14    CONNECT 19200         %    %    %    %    @    $    #
  2986.  
  2987.     15    CONNECT 7200          %    %    %    %    @    $    #
  2988.  
  2989.     16    CONNECT 12000         %    %    %    %    @    $    #
  2990.  
  2991.     17    CONNECT 14400         %    %    %    %    @    $    #
  2992.  
  2993.     18    CONNECT 16800         %    %    %    %    @    $    #
  2994.  
  2995.     19    CONNECT 38400         %    %    %    %    @
  2996.  
  2997.     20    CONNECT 57600         %    %    %    %    @
  2998.  
  2999.     21    CONNECT 76800         %    %    %    %    @
  3000.  
  3001.     22    CONNECT 115200        %    %    %    %    @
  3002.  
  3003.     23    CONNECT 230400        %    %    %    %    @
  3004.  
  3005.     24    CONNECT 460800        %    %    %    %    @
  3006.  
  3007.     25    CONNECT 921600        %    %    %    %    @
  3008.  
  3009.     26    CONNECT 307200        %    %    %    %    @
  3010.  
  3011.     27    CONNECT 153600        %    %    %    %    @
  3012.  
  3013.     28    CONNECT 102400        %    %    %    %    @
  3014.  
  3015.     29    CONNECT 61440         %    %    %    %    @
  3016.  
  3017.     30    CONNECT 51200         %    %    %    %    @
  3018.  
  3019.     31    CONNECT 624000        %    %    %    %    @
  3020.  
  3021.     32    CONNECT 124800        %    %    %    %    @
  3022.  
  3023.     33    CONNECT 62400         %    %    %    %    @
  3024.  
  3025.     34    CONNECT 41600         %    %    %    %    @
  3026.  
  3027.     35    CONNECT 31200         %    %    %    %    @    $    #
  3028.  
  3029.     36    CONNECT 24960         %    %    %    %    @
  3030.  
  3031.     37    CONNECT 20800         %    %    %    %    @
  3032.  
  3033.     38    CONNECT 33600         %    %    %    %    @    $    #
  3034.  
  3035.     39    CONNECT 28800         %    %    %    %    @    $    #
  3036.  
  3037.     40    CONNECT 26400         %    %    %    %    @    $    #
  3038.  
  3039.     41    CONNECT 24000         %    %    %    %    @    $    #
  3040.  
  3041.     42    CONNECT 21600         %    %    %    %    @    $    #
  3042.  
  3043.     43    CONNECT 48000         %    %    %    %    @    $    #
  3044.  
  3045.     44    CONNECT 56000         %    %    %    %    @    $    #
  3046.  
  3047.     45    CONNECT 64000         %    %    %    %    @    $    #
  3048.  
  3049.     46    CONNECT 112000        %    %    %    %    @    $    #
  3050.  
  3051.     47    CONNECT 128000        %    %    %    %    @    $    #
  3052.  
  3053.  
  3054.  
  3055.   Note:
  3056.  
  3057.   V       Supported
  3058.  
  3059.   %       Reporting DTE rate:
  3060.  
  3061.           <cr><lf>CONNECT DTE_Speed<cr><lf>
  3062.  
  3063.   @       For internal fax/modem:
  3064.  
  3065.           CONNECT DTE speed/Protocol Link speed/Error control level***
  3066.  
  3067.           Example: CONNECT 38400/V.32bis 14400/V.42bis
  3068.  
  3069.           For ISDN data call:
  3070.  
  3071.           <cr><lf>CONNECT DTE_Speed/Protocol DCE_Speed/Error_Control
  3072.  
  3073.                                                   [/Data_Compression]<cr><lf>
  3074.  
  3075.   $       <cr><lf>CONNECT DCE_Speed[/Error_Code]<cr><lf>
  3076.  
  3077.           Example: CONNECT 14400/ARQ
  3078.  
  3079.   #       For internal fax/modem:
  3080.  
  3081.           CONNECT Link speed/Error control (ARQ)/Error control level***
  3082.  
  3083.           Example: CONNECT 14400/ARQ/MNP5
  3084.  
  3085.           For ISDN data call:
  3086.  
  3087.           <cr><lf>CONNECT DCE_Speed/Error_Code/Protocol
  3088.  
  3089.                                  [/Error_Control[/Data_Compression]]<cr><lf>
  3090.  
  3091.   *       Use S42b6 to disable 'RINGING' result code
  3092.  
  3093.   ***     Data compression included.   'SREJ' is appended if a V.42
  3094.  
  3095.           connection with selective reject is established.
  3096.  
  3097.   Error_Code:
  3098.  
  3099.           NONE
  3100.  
  3101.           ARQ
  3102.  
  3103.   Error_Control: (This field will not show if no error control is negotiated)
  3104.  
  3105.           LAPB
  3106.  
  3107.           LAPD
  3108.  
  3109.           V42
  3110.  
  3111.   Data_Compression:
  3112.  
  3113.           V42b
  3114.  
  3115.   DTE_Speed:
  3116.  
  3117.           all possible DTE speed supported
  3118.  
  3119.   Protocol: (only ISDN protocols are listed here)
  3120.  
  3121.           X.75
  3122.  
  3123.           X.75M           ;X.75 with MLP Bundle
  3124.  
  3125.           X.75C           ;X.75 with cFos Bundle
  3126.  
  3127.           V110
  3128.  
  3129.           V120
  3130.  
  3131.           V120M           ;V.120 with MLP Bundle
  3132.  
  3133.           V120C           ;V.120 with cFos Bundle
  3134.  
  3135.           SLIP
  3136.  
  3137.           PPP
  3138.  
  3139.           BTX
  3140.  
  3141.  
  3142.  
  3143.   Use ATS35 bit 7 (ATS35.7=1) to enable the following numerical result
  3144.  
  3145.   codes when an error control connection is made.
  3146.  
  3147.  
  3148.  
  3149.       ATV0 Code    ATV1 String            ATV0 Code    ATV1 String
  3150.  
  3151.          50        CONNECT                   61        CONNECT 24000
  3152.  
  3153.          51        CONNECT 1200              62        CONNECT 26400
  3154.  
  3155.          52        CONNECT 2400              63        CONNECT 28800
  3156.  
  3157.          53        CONNECT 4800              64        CONNECT 31200
  3158.  
  3159.          54        CONNECT 7200              65        CONNECT 33600
  3160.  
  3161.          55        CONNECT 9600              66        CONNECT 38400
  3162.  
  3163.          56        CONNECT 12000             67        CONNECT 48000
  3164.  
  3165.          57        CONNECT 14400             68        CONNECT 56000
  3166.  
  3167.          58        CONNECT 16800             69        CONNECT 64000
  3168.  
  3169.          59        CONNECT 19200             70        CONNECT 112000
  3170.  
  3171.          60        CONNECT 21600             71        CONNECT 128000
  3172.  
  3173.  
  3174.  
  3175.  
  3176.  
  3177.  
  3178.  
  3179.