- Release description
- ~~~~~~~~~~~~~~~~~~~
- This is the Matrox Millennium/Mystique Windows NT Display Driver,
- version 3.00. It supports Microsoft Windows NT for x86 CPU's, version 4.0
- (Build 1381).
-
- This product includes:
-
- - Display Driver
- - MGA PowerDesk for Windows NT 4.0
-
- The driver supports 2, 4, and 8Mbytes Matrox Millennium cards, as well as
- 2 and 4MBytes Matrox Mystique cards. Up to four cards are supported.
-
- Product files
- ~~~~~~~~~~~~~
- \MGA64.INF Driver installation file for Windows NT Setup
- \MGA64.SYS Matrox Millennium/Mystique miniport driver
- \MGA64.DLL Matrox Millennium/Mystique display driver
- \README.TXT This file
-
- \MGASC.EXE Launch application for MGACTRL.EXE
- \MGAHOOK.EXE Window message hooking application
- \M_CTRL.DLL Resource file for MGACTRL.EXE
- \MGACTRL.DLL Interface functions to MGACTRL.EXE
- \MGACTRL.EXE Registry services application
- \M_DNAV.DLL Resource file for MGADNAV.EXE
- \MGADNAV.EXE MGA Desktop Navigator application
- \M_MON.DLL Resource file for MGAMON.DLL
- \MGAMON.DLL MGA Monitor property sheet
- \M_QDESK.DLL Resource file for MGAQDESK.EXE
- \MGAQDESK.EXE MGA QuickDesk application
- \M_SHEET.DLL Resource file for MGASHEET.DLL
- \MGASHEET.DLL MGA Settings property sheet
- \MGAPREV.BMP MGA Pixel Depth preview bitmaps
- \MGABKGND.BMP MGA Background bitmap for property sheets
- \MGA.MON MGA monitor file
- \MGA.BIN Binary MGA monitor database
-
- \MGAMON.HLP Help file for MGA Monitor property sheet
- \MGASHEET.HLP Help file for MGA Settings property sheet
- \ONLINE.DOC Documentation
-
- \SETUP.EXE Installation application for driver and MGA PowerDesk
- \UNINST.EXE Uninstall application
-
- Some of these files are stored in compressed format on the installation
- disk. They are automatically expanded at installation time.
-
- Installation
- ~~~~~~~~~~~~
- Refer to your Matrox Millennium/Mystique Owner's Manual to install your
- card in your system.
-
- If you are installing multiple Matrox Millennium cards in your system,
- please note that only one should be VGA-enabled through the on-board switch.
-
- Matrox Mystique cards are always VGA-enabled. If you are installing
- multiple Matrox Mystique cards in your system, your system BIOS must disable
- all VGA-enabled cards it finds after the first one. When Windows NT starts,
- the miniport driver will find all cards and enable them for use. THIS IS
- GUARANTEED ONLY IF YOUR SYSTEM BIOS IS FULLY PCI-COMPLIANT. IF YOUR
- SYSTEM BIOS IS NOT FULLY PCI-COMPLIANT, MULTIPLE MYSTIQUE CARDS MAY NOT WORK.
-
- Multiple-card installations are similar to single-card installations.
- The system will automatically assign separate addresses to each PCI card,
- allowing the driver to issue commands to each card. In a multiple-card
- configuration, all cards must be either Millennium or Mystique cards, and
- all cards must run with the same resolution and pixel depth (number of
- colors). The VGA-enabled card will drive the top left monitor.
-
- To install the Matrox Millennium/Mystique drivers, run the Setup utility
- supplied with the drivers:
-
- - Start the Windows NT Explorer, or open a Command Prompt window.
-
- - Go to the drive and directory holding the driver installation files.
-
- - Double-click on the Setup application, or type 'setup' and press
- Enter.
-
- The Setup utility will query you about your preferred installation location
- and the components you wish to install. You must restart your computer
- before the changes take effect.
-
- You can also use the standard Windows NT procedure to install the drivers
- (without the MGA PowerDesk). The general procedure is the following:
-
- - Right-click on the desktop, select 'Properties'. This will open
- Display Properties.
-
- - Select the 'Settings' tab.
-
- - Press the 'Display Type...' button.
-
- - In the Display Type dialog box, press the 'Change...' button.
-
- - In the Change Display dialog box, press the 'Have Disk...' button.
-
- - In the Install From Disk dialog box, type the location of the
- Matrox Millennium/Mystique installation files (e.g. "A:\" or
- "D:\WINNT").
-
- - From the displayed list, select the model of your display adapter,
- and press 'OK'.
-
- - Answer 'Yes' to the Third-party Drivers dialog box.
-
- - Press 'OK' in the Installing Driver message box.
-
- - Press 'Close' in the Display Type dialog box.
-
- - Press 'Close' in the Display Properties applet.
-
- - In the System Settings Change dialog box, you should select 'Yes'
- so that the new settings take effect.
-
- Using MGA PowerDesk
- ~~~~~~~~~~~~~~~~~~~
- Changing resolution, selecting a monitor, and using the MGA PowerDesk is
- covered in the "online.doc" file. You can view this file with WordPad.
-
- Registry settings (for advanced users only)
- ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
- Information held in the Windows NT registry can have a direct effect on the
- whole system. Introducing incorrect values can cause serious problems and
- may make it necessary to reinstall Windows NT. The changes outlined below
- should have effects limited to the Matrox Millennium/Mystique drivers.
- However, if you accidentally modify values that make your system unusable,
- please note that it is often possible to undo the damage by using the
- 'Last Known Good Configuration' option at boot time. It is also possible
- to save a copy of your registry settings prior to any modification.
-
- The configuration of the MGA Windows NT driver and of MGA PowerDesk is saved
- in the registry. The most important parameters can be modified through the
- MGA PowerDesk, but others can be accessed only through the Registry Editor.
- Most users will find that the default values are best for their system.
- However, specific problems will be solved through these switches. The
- values are:
-
- User.AlternateLines when set to 1, allows lines defined by integer coordinates
- to be drawn using the faster AUTOLINE opcode of the
- drawing engine. The convention used to determine which
- pixels contribute to a given line is slightly different
- in AUTOLINE and in Windows NT. Setting AlternateLines
- to 1 trades off compliance with the Windows NT conventions
- for performance. A value of 0 will enforce compliance.
- Lines defined by non-integer endpoint coordinates are not
- affected by this setting.
-
- The default value of User.AlternateLines is 0.
-
- User.CenterDialogs has no effect on Windows NT 4.0.
-
- The default value of User.CenterDialogs is 0.
-
- User.ComplexBlt when set to 1, allows the hardware to accelerate some
- complex raster operations (ROPs) by executing a sequence
- of simple ROPs (ORing, ANDing, etc...). A value of 0
- will result in complex ROPs being performed in software.
-
- The complex ROPs are performed directly on the display
- through a succession of simple ROPs. Artifacts (flashing)
- in the target display area may become visible when an
- intermediate result in video RAM is displayed on a given
- refresh cycle, to be replaced by the final image on the
- next cycle.
-
- The default value of User.ComplexBlt is 1.
-
- User.DeviceBitmaps when set to 1, allows use of off-screen memory for
- caching bitmaps. This will allow the hardware to
- accelerate drawing to bitmaps. A value of 0 disables
- bitmap caching, allowing the CPU to draw onto all
- bitmaps. Bitmap caching is internally disabled when
- a desktop requiring more than one card is in use,
- regardless of the registry setting.
-
- The default value of User.DeviceBitmaps is 1.
-
- User.EnableUSWC when set to 1, allows direct frame buffer access to use
- the Write Combining feature of the Pentium Pro processor.
- Setting this value to 0 may result in slightly lower
- performance.
-
- The default value of User.EnableUSWC is 1.
-
- User.MgaInfoFile when set to 1, allows use of the MGA PowerDesk to
- control refresh rates. A value of 0 will allow all
- available refresh rates to be listed.
-
- The default value of User.MgaInfoFile is 1.
-
- User.SynchronizeDac when set to 1, will require the driver to wait for a
- vertical sync before programming the ramdac with a new
- pointer shape or a new palette. If you notice stray
- pixels flashing around the pointer, setting this flag
- to 1 might fix the problem. Setting it to 0 will result
- in slightly better performance.
-
- The default value of User.SynchronizeDac is 0.
-
- User.SynchronizeEngine when set to 1, will require the driver to wait for
- the Millennium hardware to be ready to accept new data
- before programming the next operation. Setting it to 0
- will result in better performance.
-
- On most x86-based systems, the PCI logic should ensure
- that such a check is redundant. If you're experiencing
- problems that might be related to timing (with
- communication programs, for instance), setting this value
- to 1 may be of help.
-
- The default value of User.SynchronizeEngine is 0.
-
- Modifying keys and values in the registry is done through the Registry
- Editor. The Registry Editor can be invoked in the following way:
-
- - Use Start/Run..., or open a Command Prompt window, and type
- 'regedt32'. Alternately, from the Windows NT Explorer, go to
- SystemRoot\system32 and double-click on Regedt32. The Registry
- Editor will come up.
-
- To examine or to modify the values that govern the behavior of the Matrox
- Millennium/Mystique driver:
-
- - Select the HKEY_LOCAL_MACHINE window.
-
- - Travel down to the key named:
- HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Services\mga64\Device0.
-
- You will find the values in the right window pane. To modify any of
- them:
-
- - Double-click on the selected value.
-
- - In the DWORD Editor, change the value to '0' or '1'. The new value
- will take effect the next time you reboot.
-
- PowerDesk settings are kept under the key:
- HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Services\MGACtrl
- and its subkeys.
-
- Hardware-accelerated 3D
- ~~~~~~~~~~~~~~~~~~~~~~~
- The Mini-Client Driver (MCD), which is part of the Millennium/Mystique
- display driver, allows for hardware-accelerated 3D, with a few restrictions:
-
- - Currently no acceleration is available when multiple cards are
- in use.
-
- - The MCD does not support 8bpp (256 colors) and 24bpp (16777216
- colors) modes. The 15bpp (32K colors), 16bpp (64K colors), and
- 32bpp (True Color) modes are the ones that can be hardware-
- accelerated.
-
- - Limitations to the available resolutions are to be expected. All
- 3D modes require extra memory to handle double buffering and/or Z
- buffering, and this memory is no longer available for display.
-
- The 3D driver can be configured through MGA PowerDesk or through two
- registry switches:
-
- User3D.DoubleBuffer when set to 1, allows a back buffer to be allocated
- from the Matrox Millennium or Mystique memory. It
- should be set to 0 if no back buffer is required.
-
- This value should be set to 1 if 3D animation is to
- be fully accelerated.
-
- User3D.ZBuffer when set to 1, allows a Z buffer to be allocated from
- the Matrox Millennium or Mystique memory. It should
- be set to 0 if no Z buffer is required.
-
- This value should be set to 1 if 3D rendering is to
- be fully accelerated.
-
- The default value for the User3D switches is 1. Setting both values to 0
- effectively disables the hardware-accelerated 3D. The recommended way of
- modifying them is through MGA PowerDesk rather than through the Registry
- Editor.
-
- The back- and Z-buffers can be allocated on a per-window basis. This makes
- the availability of 3D-acceleration difficult to ascertain, since it would
- be possible to get 3D-acceleration for a small window even when offscreen
- memory is scarce, while a request for full-screen buffers would fail even
- when relatively large areas of offscreen memory are available.
-
- Notes, Problems, and Limitations
- ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
-
- Systems using more than one PCI bus
- It is possible that a switch to a full-screen Command Prompt, or any
- change of mode, will result in a blue-screen crash if a card is
- installed on a PCI bus other than bus 0. The problem is under
- investigation. Moving the card to a different PCI slot is a possible
- workaround.
-
- There are systems where Windows NT reports conflicts between adapters
- installed beyond the PCI bridge. In this case, the MGA Millennium
- miniport driver cannot access its own card. If your system appears
- unable to find the Millennium card, try moving it to a different PCI
- slot.
-
- DirectDraw on multiple cards
- DirectDraw cannot currently handle direct access to a desktop spread
- over multiple cards. Applications that require DirectDraw will not
- run on such a desktop.
-
- Testing 1600x1280 and 1800x1440 resolutions for PowerDoc cards
- If you encounter problems testing these very high resolution modes
- in the MGA Monitor property sheet, first test a lower resolution
- mode (say, 640x480) using the monitor settings you wish to apply,
- then press 'OK' to close Display Properties. You will be able to
- test the higher resolution modes when you re-open Display Properties
- and go to the MGA Monitor tab.
-
- Corruption using the 3D-Maze screen saver
- This problem appears only after installing the Service Pack 2 for
- Windows NT 4.0. The problem is probably not within the driver.
-
-