  1.    6 Workstation: NetWare Client 32
  2.                                                                    v1.11
  3.  
  4.  
  5. NetWare* Client 32 for Windows* 95 and DOS/Windows 3.1x with Intel's
  6. EtherExpress(TM) PRO/100+ PCI adapter
  7. ====================================================================
  8.  
  9. Location of Drivers:  \NWSERVER\E100B.LAN
  10.  
  11.                       \NWSERVER\E100B.LDI
  12.  
  13.  
  14.  
  15. Install the latest drivers available for this adapter. At
  16. publicationtime (April 1997), the latest drivers are on the
  17. Configuration and Drivers Disk that comes with this adapter.
  18.  
  19.  
  20.  
  21. General Installation of Client 32 with Windows 95 using Intel's 32 bit
  22. LAN driver
  23. -----------------------------------------------------------------------
  24.  
  25. Prerequisite:
  26.  
  27. 1. Windows 95 operating system installed.
  28.  
  29. 2. NetWare Client 32 for Windows 95 archive file and any patch files.
  30.  
  31. 3. Access to the Windows 95 CD or CAB files, since the Client 32
  32.    installation will ask for it.
  33.  
  34. 4. Access to the latest drivers available from online services.
  35.  
  36.  
  37. General Instructions
  38. --------------------
  39.  
  40. 1. If the Intel EtherExpress PCI adapter is being installed for the
  41.    first time when Client 32 is being added, install the adapter
  42.    hardware as described in the manual and go to step 2. If the adapter
  43.    is already installed on the Windows 95 system, go to step 3.
  44.  
  45. 2. When Windows 95 is restarting, it may display the message "Windows
  46.    has found new hardware and is installing software for it". Select the
  47.    option labeled "Do not install a driver (Windows will not prompt you
  48.    again)" then click on OK.
  49.  
  50. 3. Run the SETUP.EXE program for Client 32. It is located in the
  51.    \ENGLISH subdirectory of the Client 32 software.
  52.  
  53. 4. On the NetWare Client 32 Installation screen, make sure the "Upgrade
  54.    NDIS driver to ODI, if available" box is checked if you are replacing
  55.    the NDIS driver with the ODI.
  56.  
  57. 5. When the Select Devices screen appears, highlight "Intel" under
  58.    Manufacturers and select "Intel EtherExpress (TM) PRO/100+ PCI
  59.    Adapter (ODI)" under Models. Click OK to install the driver.
  60.  
  61. 6. On the Recommended NetWare Client 32 properties screen, set the
  62.    appropriate settings for the version of NetWare you are using.
  63.  
  64. 7. The Client 32 installation program will copy files. It may ask for
  65.    the source of the Windows 95 installation files. Click OK and then
  66.    enter the correct path to the files.
  67.  
  68. 8. The Client 32 installation will finish, and you must reboot in order
  69.    for the changes to become effective.
  70.  
  71. 9. When Windows 95 reboots you may receive a DOS box message, "Command
  72.    line parameter Prompt for E100B". Note the supported Slot value and
  73.    select OK to continue. If you see a message "E100B.LAN did not remain
  74.    resident ....", ignore it.
  75.  
  76. 10.To prevent the Slot message from appearing each time Windows 95 is
  77.    rebooted, right click the Network Neighborhood Icon. Click
  78.    Properties. Highlight the "Intel EtherExpress(TM) PRO/100+ PCI
  79.    Adapter(ODI)" and click Properties. Select the Advanced tab. Under
  80.    Properties highlight Slot. Under Value, type in the slot value noted
  81.    in step 9 and click OK twice. You will need to restart Windows 95.
  82.  
  83.  
  84. Hints and Tips for Client 32 in Windows 95
  85. ------------------------------------------
  86.  
  87. 1. If the Intel EtherExpress PCI adapter driver loads as an "ATI AT-2560
  88.    Series PCI/100 Ethernet Adapter (ODI)", then the wrong driver has
  89.    been installed. This can be easily corrected as follows:
  90.    
  91.    a) In the INF directory, which is located off the Windows 95
  92.       directory, rename the file A2560.INF to A2560.BAK (or some other
  93.       name that doesn't end in .INF).
  94.    
  95.    b) Go to Device Manager by right clicking on the Network Neighborhood
  96.       Icon. Click Properties. Select the Device Manager tab. Highlight
  97.       the "ATI AT-2560 Series PCI/100 Ethernet Adapter (ODI) and select
  98.       remove. Next, highlight Novell ODINSUP and select remove. Restart
  99.       Windows 95 after both entries have been removed.
  100.  
  101. 2. Message - Module c:\novell\client32\e100b.lan did not remain
  102.    resident: Occasionally on restarting Windows 95 after the Client 32
  103.    installation, this NetWare Alert message appears. If you click on OK,
  104.    another message says that "The hardware configuration conflicts
  105.    E100B.LAN-NW-Adapter 0-Board-0". The ODINSUP device did not load
  106.    properly (Device Manager doesn't show it under Network Adapters).
  107.    Shut down the system and reboot. This action should load ODINSUP
  108.    successfully.
  109.  
  110. 3. PRO/10+ PCI adapter driver loads indicating it is a PRO/100+ adapter:
  111.    If a problem occurs loading the driver, the driver may default to
  112.    indicating it is a PRO/100+. This condition will not cause any
  113.    problems since these two adapters use the same drivers. The only
  114.    consideration to be aware of is if any advanced settings have to be
  115.    made for the adapter. Speed is not a valid option for the PRO/10+
  116.    PCI, and it will always operate at 10mbps. The Force Duplex option
  117.    defaults to Auto-negotiate which isn't supported on the PRO/10+ PCI.
  118.    It will operate in half duplex. If you need Full Duplex, set it
  119.    specifically for Full.
  120.  
  121.  
  122. General Installation of Client 32 with DOS/Windows 3.1x
  123. -------------------------------------------------------
  124.  
  125. 1. From the Novell NetWare Client 32 software, run INSTALL.EXE.
  126.  
  127. 2. Select the NetWare Client 32 products you want to install from the on
  128.    your workstation from the list:
  129.       
  130.       [X] NetWare Client 32 for DOS
  131.       [X] NetWare Client 32 for Windows
  132.       [ ] NetWare TCP/IP protocol stack
  133.            [ ] NetWare IP (TCP/IP Required)
  134.       [ ]Desktop SNMP
  135.            [ ] HOSTMIB for SNMP (SNMP Required)
  136.       [ ] NetWare TSA for SMS
  137.  
  138.  
  139.       
  140.       Note - "NetWare Client 32 for DOS" and "NetWare Client 32 for
  141.             Windows" are usually selected by default.
  142.  
  143. 3. From the Customize Support for Windows menu, specify if you want to
  144.    use multiple country codes or if you want to set the shared Windows
  145.    path. The default for both of these is NO.
  146.  
  147. 4. From the Select LAN Driver Type menu, select "32-bit LAN drivers".
  148.  
  149. 5. From the 32-Bit Network Board Drivers menu, select
  150.  
  151.         "USER SPECIFIED 32 BIT DRIVER"
  152.  
  153.    Insert the driver diskette and type "A:\NWSERVER", select:
  154.  
  155.         "Intel EtherExpress PRO/100+ LAN Adapter"
  156.  
  157. 6. <OPTIONAL> Specify the following settings for the Intel EtherExpress
  158.    LAN adapter:
  159.  
  160.           Parameter                       Default
  161.           -------------                   -------
  162.            Speed (100B only)               0 (auto detect)
  163.            IOMAPMODE                       Memory Mapped
  164.            Forceduplex                     0 (auto negotiate)
  165.            Frame Type                      Ethernet_802.2
  166.                                            Ethernet_802.3
  167.       
  168.       Note: The default settings will work for most installations. If
  169.             you use multiple frame types, please see Hints and Tips
  170.             section below.
  171.  
  172. 7. From the Installation Configuration Summary, verify the default
  173.    settings for Client 32 are correct, or modify as necessary.
  174.       
  175.       Modify AUTOEXEC.BAT and CONFIG.SYS      [YES]
  176.       
  177.       Client Directory:       C:\NOVELL\CLIENT32
  178.       Windows Directory:      C:\WINDOWS
  179.       LAN driver type:        32-bit LAN drivers
  180.       LAN driver:             Intel EtherExpress(TM) PCI Adapters
  181.  
  182. 8. Novell NetWare will now copy the files to your workstations and
  183.    modify the configuration files to match your selected configuration.
  184.  
  185.  
  186. Hints and Tips
  187. --------------
  188.  
  189. 1. If you are using multiple frame types, you will get the following
  190.    message when you load the driver:
  191.       
  192.       "Do you want to load another frame type for a previously loaded
  193.       board?  Y/N "
  194.  
  195.    The way to avoid this is to add the slot number to the load line for
  196.    the driver in the STARTNET.BAT (by default it is located in the
  197.    \NOVELL\CLIENT32 directory). The only way to determine the slot
  198.    number Novell is expecting is to put an invalid value on the load
  199.    line. For example (and the load line should be all on one line):
  200.       
  201.            LOAD C:\NOVELL\CLIENT32\E100B.LAN SPEED=0 IOMAPMODE=0
  202.            FORCEDUPLEX=0 FRAME=ETHERNET_802.2 SLOT=e
  203.  
  204.    When you next reboot, you will be prompted with the correct value.
  205.    Modify the STARTNET.CFG again, and use that value. If the slot is not
  206.    specified correctly, only the first frame type will load.
  207.  
  208. 2. Check for a LASTDRIVE statement in the CONFIG.SYS file. You must have
  209.    LASTDRIVE=Z in config.sys when using Client 32.
  210.  
  211. 3. Verify that you have FIRST NETWORK DRIVE = F in the NET.CFG file
  212.    under the NetWare DOS Requester section.
  213.       
  214.       NOTE: NET.CFG is position sensitive, so be careful to indent lines
  215.             with one space or one tab as shown above in the example.
  216.  
  217. 4. Verify that the EtherExpress adapter passes the diagnostics test by
  218.    running SETUP.EXE on the EtherExpress driver disk. If the adapter
  219.    fails diagnostics it will not function correctly running Client 32.
  220.  
  221. 5. Using 16-bit ODI driver with Client 32 requires CLIENT32.NLM dated
  222.    10/09/96 or later. The driver will not load with older versions.
  223.  
  224. Sample Configurations
  225. ---------------------
  226.  
  227. Below are sample files from a Novell NetWare Client 32 workstation with
  228. a EtherExpress adapter installed using the default installation:
  229.    
  230.    CONFIG.SYS
  231.    ----------
  232.    
  233.    DEVICE=C:\WINDOWS\HIMEM.SYS
  234.    BUFFERS=30,0
  235.    FILES=60
  236.    LASTDRIVE=Z
  237.    
  238.    
  239.    
  240.    AUTOEXEC.BAT
  241.    ------------
  242.    
  243.    prompt $P$G
  244.    path=C:\WINDOWS;c:\dos;C:\NOVELL\CLIENT32\
  245.    SET TEMP=C:\TEMP
  246.    @CALL C:\NOVELL\CLIENT32\STARTNET
  247.    
  248.    
  249.    
  250.    STARTNET.BAT
  251.    ------------
  252.    
  253.    SET NWLANGUAGE=ENGLISH
  254.    C:\NOVELL\CLIENT32\NIOS.EXE
  255.    LOAD C:\NOVELL\CLIENT32\LSLC32.NLM
  256.    LOAD C:\NOVELL\CLIENT32\CMSM.NLM
  257.    LOAD C:\NOVELL\CLIENT32\ETHERTSM.NLM
  258.    LOAD C:\NOVELL\CLIENT32\E100B.LAN SPEED=0 IOMAPMODE=0 FORCEDUPLEX=0
  259.         FRAME=ETHERNET_802.2 SLOT=2
  260.    LOAD C:\NOVELL\CLIENT32\E100B.LAN SPEED=0 IOMAPMODE=0 FORCEDUPLEX=0
  261.         FRAME=ETHERNET_802.3 SLOT=2
  262.    LOAD C:\NOVELL\CLIENT32\IPX.NLM
  263.    LOAD C:\NOVELL\CLIENT32\CLIENT32.NLM
  264.       
  265.       NOTE: If you are loading multiple frame types, you will need to
  266.             specify the slot number of the adapter on the load lines.
  267.             See Hints and Tips section above for detailed information.
  268.    
  269.    NET.CFG
  270.    -------
  271.    
  272.    NetWare DOS Requester
  273.       FIRST NETWORK DRIVE F
  274.       NETWARE PROTOCOL NDS BIND
  275.    
  276.    Protocol IPX
  277.       IPX SOCKETS 40
  278.  