  1. ; Copyright Schneider & Koch & Co. Datensysteme GmbH 1993
  2. ; EISA-Konfigurationsfile f〉 SK-NET G16 
  3. ;
  4. ; 12/08/93 Rev. 2.0
  5. ;
  6. ; Beinhaltet Ressourcen f〉 I/O, Shared Memory, BootPROM, Interrupts. 
  7. ; POS Adresse und BOOT-PROM Basisadresse muss von Hand eingestellt werden,
  8. ; Shared Memory, Interrupt, BootPROM disable/enable werden per EISA 
  9. ; Konfiguration eingestellt. CARD ENABLE wird NICHT ausgef”rt !!!
  10.  
  11. BOARD
  12.    ID       = "SKDE000"
  13.    NAME     = "SK-NET G16 LAN Interface Board"
  14.    MFR      = "Schneider & Koch GmbH"
  15.    CATEGORY = "NET"
  16.    SLOT     = ISA16
  17.    AMPERAGE = 1500
  18.    LENGTH   = 162
  19.    SKIRT    = NO
  20.    COMMENTS = "SK-NET G16 Board:\n
  21.    product-number 11-11-059 (70-00-004)"
  22.  
  23. JUMPER(1) = 8
  24.    NAME     = "W2"
  25.    JTYPE    = PAIRED
  26.    REVERSE  = YES
  27.    LABEL    = LOC(1-8) "W2""W2""W2""W2""W2""W2""W2""W2"
  28.    FACTORY  = LOC(1-8) 10101010
  29.    COMMENTS = "
  30. Selects 8 or 16 Bit operation"
  31.  
  32. JUMPER(2) = 8
  33.    NAME     = "TR2"
  34.    JTYPE    = PAIRED
  35.    VERTICAL = NO
  36.    REVERSE  = YES
  37.    LABEL    = LOC(1-8) "BNC""BNC""BNC""BNC""BNC""BNC""BNC""BNC" 
  38.    FACTORY  = LOC(1-8) 11111111 
  39.    COMMENTS = "
  40.  Set the Transformer to Position TR2 (BNC) for 10BASE-2 (factory default)"
  41.  
  42. JUMPER(3) = 8
  43.    NAME     = "TR1"
  44.    JTYPE    = PAIRED
  45.    VERTICAL = YES
  46.    REVERSE  = YES
  47.    LABEL    = LOC (1-8) "DIX""DIX""DIX""DIX""DIX""DIX""DIX""DIX" 
  48.    FACTORY  = LOC (1-8) 00000000 
  49.    COMMENTS = "
  50.  Set the Transformer to Position TR1 (DIX) for AUI."
  51.  
  52.  
  53. SWITCH(1) = 8
  54.    NAME     = "W1"
  55.    STYPE    = DIP
  56.    LABEL    = LOC(1-8) "INT0" "XTEP" "EP0" "EP1" "EP2" "IO0" "IO1" "IO2"
  57.    REVERSE  = YES
  58.    FACTORY  = LOC(1-8) 01000000
  59.    COMMENTS = "
  60.  INT0       Position ON will enable IRQ3. (COM2 is also using IRQ3 !!!) \n
  61.  XTEP       will enable (OFF) / disable (ON) Boot-PROM\n
  62.  EP0-EP2    start address Boot-PROM\n
  63.  IO0-IO2    I/O address for POS (Programmable Option Select)\n
  64. \n
  65. Warning :   Invalid POS I/O switch setting will cause\n
  66. Warning :   unpredictable results and incorrect display of\n
  67. Warning :   your EISA configuration !"
  68.   
  69.  
  70. SOFTWARE(1) = "
  71.  The current settings of your SK-NET G16 Ethernet Interface\n 
  72. Card are:\n"
  73.  
  74. IOPORT(3) = PORTVAR(3) 
  75.          INITVAL=00xxxxxxb
  76. IOPORT(4) = PORTVAR(4) 
  77.          INITVAL=0000xx00b
  78. IOPORT(2) = PORTVAR(2)                          ; never set card enable !!!
  79.          INITVAL=000000x0b
  80.         
  81.  
  82. FUNCTION = "Ethernet Adapter"
  83.    TYPE = "NET,ETH"
  84.    CONNECTION  = "BNC and DIX connector."
  85.  
  86.    SUBFUNCTION = "I/O Address for POS"
  87.       CHOICE = "390h"
  88.         PORTVAR(2)=392h
  89.         PORTVAR(3)=393h
  90.         PORTVAR(4)=394h
  91.         LINK
  92.         PORT = 390h-397h
  93.         INIT = SWITCH(1) LOC(6-8) 000
  94.         INIT = SOFTWARE(1) "I/O Base = 390h"
  95.             
  96.       CHOICE = "320h"
  97.         PORTVAR(2)=322h
  98.         PORTVAR(3)=323h
  99.         PORTVAR(4)=324h
  100.         LINK
  101.         PORT = 320h-327h
  102.         INIT = SWITCH(1) LOC(6-8) 001
  103.         INIT = SOFTWARE(1) "I/O Base = 320h"
  104.  
  105.       CHOICE = "328h"
  106.         PORTVAR(2)=32Ah
  107.         PORTVAR(3)=32Bh
  108.         PORTVAR(4)=32Ch
  109.         LINK
  110.         PORT = 328h-32fh
  111.         INIT = SWITCH(1) LOC(6-8) 100
  112.         INIT = SOFTWARE(1) "I/O Base = 328h"
  113.  
  114.       CHOICE = "288h"
  115.         PORTVAR(2)=28Ah
  116.         PORTVAR(3)=28Bh
  117.         PORTVAR(4)=28Ch
  118.         LINK
  119.         PORT = 288h-28fh
  120.         INIT = SWITCH(1) LOC(6-8) 010
  121.         INIT = SOFTWARE(1) "I/O Base = 288h"
  122.                                   
  123.       CHOICE = "220h"
  124.         PORTVAR(2)=222h
  125.         PORTVAR(3)=223h
  126.         PORTVAR(4)=224h
  127.         LINK
  128.         PORT = 220h-227h
  129.         INIT = SWITCH(1) LOC(6-8) 110
  130.         INIT = SOFTWARE(1) "I/O Base = 220h"
  131.       
  132.     CHOICE = "208h"
  133.         PORTVAR(2)=20Ah
  134.         PORTVAR(3)=20Bh
  135.         PORTVAR(4)=20Ch
  136.         LINK
  137.         PORT = 208h-20fh
  138.         INIT = SWITCH(1) LOC(6-8) 101
  139.         INIT = SOFTWARE(1) "I/O Base = 208h"
  140.       
  141.       CHOICE = "180h"
  142.         PORTVAR(2)=182h
  143.         PORTVAR(3)=183h
  144.         PORTVAR(4)=184h
  145.         LINK
  146.         PORT = 180h-187h
  147.         INIT = SWITCH(1) LOC(6-8) 011
  148.         INIT = SOFTWARE(1) "I/O Base = 180h"
  149.       
  150.       CHOICE = "100h"
  151.         PORTVAR(2)=102h
  152.         PORTVAR(3)=103h
  153.         PORTVAR(4)=104h
  154.         LINK
  155.         PORT = 100h-107h
  156.         INIT = SWITCH(1) LOC(6-8) 111
  157.         INIT = SOFTWARE(1) "I/O Base = 100h"
  158.  
  159.  
  160.    SUBFUNCTION = "RAM Base Address"
  161.       
  162.       CHOICE = "CC000"
  163.      LINK
  164.         MEMORY  = 16K
  165.         ADDRESS = 0CC000h
  166.         INIT = SOFTWARE(1) "RAM Base Address CC000h"
  167.         INIT = IOPORT(3) LOC(5-0) 110011
  168.       
  169.       CHOICE = "D0000"
  170.      LINK
  171.         MEMORY  = 16K
  172.         ADDRESS = 0D0000h
  173.         INIT = SOFTWARE(1) "RAM Base Address D0000h"
  174.         INIT = IOPORT(3) LOC(5-0) 110100
  175.       
  176.       CHOICE = "D4000"
  177.      LINK
  178.         MEMORY  = 16K
  179.         ADDRESS = 0D4000h
  180.         INIT = SOFTWARE(1) "RAM Base Address D4000h"
  181.         INIT = IOPORT(3) LOC(5-0) 110101
  182.  
  183.       CHOICE = "D8000"
  184.      LINK
  185.         MEMORY  = 16K
  186.         ADDRESS = 0D8000h
  187.         INIT = SOFTWARE(1) "RAM Base Address D8000h"
  188.         INIT = IOPORT(3) LOC(5-0) 110110
  189.  
  190.       CHOICE = "DC000"
  191.      LINK
  192.         MEMORY  = 16K
  193.         ADDRESS = 0DC000h
  194.         INIT = SOFTWARE(1) "RAM Base Address DC000h"
  195.         INIT = IOPORT(3) LOC(5-0) 110111
  196.  
  197.       CHOICE = "E0000"
  198.      LINK
  199.         MEMORY  = 16K
  200.         ADDRESS = 0E0000h
  201.         INIT = SOFTWARE(1) "RAM Base Address E0000h"
  202.         INIT = IOPORT(3) LOC(5-0) 111000
  203.       
  204.       CHOICE = "E4000"
  205.      LINK
  206.         MEMORY  = 16K
  207.         ADDRESS = 0E4000h
  208.         INIT = SOFTWARE(1) "RAM Base Address E4000h"
  209.         INIT = IOPORT(3) LOC(5-0) 111001
  210.  
  211.       CHOICE = "E8000"
  212.      LINK
  213.         MEMORY  = 16K
  214.         ADDRESS = 0E8000h
  215.         INIT = SOFTWARE(1) "RAM Base Address E8000h"
  216.         INIT = IOPORT(3) LOC(5-0) 111010
  217.  
  218.       CHOICE = "EC000"
  219.      LINK
  220.         MEMORY  = 16K
  221.         ADDRESS = 0EC000h
  222.         INIT = SOFTWARE(1) "RAM Base Address EC000h"
  223.         INIT = IOPORT(3) LOC(5-0) 111011
  224.  
  225.       CHOICE = "B0000"
  226.      LINK
  227.         MEMORY  = 16K
  228.         ADDRESS = 0B0000h
  229.         INIT = SOFTWARE(1) "RAM Base Address B0000h"
  230.         INIT = IOPORT(3) LOC(5-0) 101100
  231.       
  232.       CHOICE = "C0000"
  233.      LINK
  234.         MEMORY  = 16K
  235.         ADDRESS = 0C0000h
  236.         INIT = SOFTWARE(1) "RAM Base Address C0000h"
  237.         INIT = IOPORT(3) LOC(5-0) 110000
  238.       
  239.       CHOICE = "C4000"
  240.      LINK
  241.         MEMORY  = 16K
  242.         ADDRESS = 0C4000h
  243.         INIT = SOFTWARE(1) "RAM Base Address C4000h"
  244.         INIT = IOPORT(3) LOC(5-0) 110001
  245.       
  246.       CHOICE = "C8000"
  247.      LINK
  248.         MEMORY  = 16K
  249.         ADDRESS = 0C8000h
  250.         INIT = SOFTWARE(1) "RAM Base Address C8000h"
  251.         INIT = IOPORT(3) LOC(5-0) 110010
  252.  
  253. SUBFUNCTION = "IRQ Line"
  254.       CHOICE = "IRQ 9"
  255.      FREE
  256.         IRQ = 9
  257.         INIT = SOFTWARE(1) "IRQ 9"
  258.         INIT = IOPORT(4) LOC(3 2)10
  259.         INIT = SWITCH(1) LOC(1) 0                   ;IRQ3 disabled
  260.  
  261.       CHOICE = "IRQ 3"
  262.      FREE
  263.         IRQ = 3
  264.         INIT = SOFTWARE(1) "IRQ 3"
  265.         INIT = IOPORT(4) LOC(3 2)00
  266.         INIT = SWITCH(1) LOC(1) 1                   ;IRQ3 enabled
  267.  
  268.       CHOICE = "IRQ 5"
  269.      FREE
  270.         IRQ = 5
  271.         INIT = SOFTWARE(1) "IRQ 5"
  272.         INIT = IOPORT(4) LOC(3 2)01
  273.         INIT = SWITCH(1) LOC(1) 0                   ;IRQ3 disabled
  274.  
  275.       CHOICE = "IRQ 11"
  276.      FREE
  277.         IRQ = 11
  278.         INIT = SOFTWARE(1) "IRQ 11"
  279.         INIT = IOPORT(4) LOC(3 2)11
  280.         INIT = SWITCH(1) LOC(1) 0                   ;IRQ3 disabled
  281.  
  282.    SUBFUNCTION = "Boot-PROM Start Address"
  283.  
  284.       CHOICE = "disabled"
  285.         FREE
  286.         INIT = SWITCH(1) LOC(2-5) 1000
  287.         INIT = SOFTWARE(1) "Boot-PROM disabled"
  288.         INIT = IOPORT(2) LOC(1)1
  289.       
  290.       CHOICE = "DC000"
  291.      LINK
  292.         MEMORY  = 16K
  293.         ADDRESS = 0DC000h
  294.         INIT = SWITCH(1) LOC(2-5) 0000
  295.         INIT = SOFTWARE(1) "Boot-PROM DC000h"
  296.         INIT = IOPORT(2) LOC(1)0
  297.         
  298.       CHOICE = "D8000"
  299.      LINK
  300.         MEMORY  = 16K
  301.         ADDRESS = 0D8000h
  302.         INIT = SWITCH(1) LOC(2-5) 0100
  303.         INIT = SOFTWARE(1) "Boot-PROM D8000h"
  304.         INIT = IOPORT(2) LOC(1)0
  305.  
  306.       CHOICE = "D4000"
  307.      LINK
  308.         MEMORY  = 16K
  309.         ADDRESS = 0D4000h
  310.         INIT = SWITCH(1) LOC(2-5) 0010
  311.         INIT = SOFTWARE(1) "Boot-PROM D4000h"
  312.         INIT = IOPORT(2) LOC(1)0
  313.  
  314.       CHOICE = "D0000"
  315.      LINK
  316.         MEMORY  = 16K
  317.         ADDRESS = 0D0000h
  318.         INIT = SWITCH(1) LOC(2-5) 0110
  319.         INIT = SOFTWARE(1) "Boot-PROM D0000h"
  320.         INIT = IOPORT(2) LOC(1)0
  321.  
  322.       CHOICE = "CC000"
  323.      LINK
  324.         MEMORY  = 16K
  325.         ADDRESS = 0CC000h
  326.         INIT = SWITCH(1) LOC(2-5) 0001
  327.         INIT = SOFTWARE(1) "Boot-PROM CC000h"
  328.         INIT = IOPORT(2) LOC(1)0
  329.  
  330.       CHOICE = "C8000"
  331.      LINK
  332.         MEMORY  = 16K
  333.         ADDRESS = 0C8000h
  334.         INIT = SWITCH(1) LOC(2-5) 0101
  335.         INIT = SOFTWARE(1) "Boot-PROM C8000h"
  336.         INIT = IOPORT(2) LOC(1)0
  337.  
  338.       CHOICE = "C4000"
  339.      LINK
  340.         MEMORY  = 16K
  341.         ADDRESS = 0C4000h
  342.         INIT = SWITCH(1) LOC(2-5) 0011
  343.         INIT = SOFTWARE(1) "Boot-PROM C4000h"
  344.         INIT = IOPORT(2) LOC(1)0
  345.  
  346.       CHOICE = "C0000"
  347.      LINK
  348.         MEMORY  = 16K
  349.         ADDRESS = 0C0000h
  350.         INIT = SWITCH(1) LOC(2-5) 0111
  351.         INIT = SOFTWARE(1) "Boot-PROM C0000h"
  352.         INIT = IOPORT(2) LOC(1)0
  353.  
  354.    SUBFUNCTION = "8/16 Bit Mode"
  355.       HELP = "Selects bus interface, close odd numbers of W2
  356.       for 16Bit bus interface, or even numbers for 8Bit operation"
  357.      Choice  = "16 Bit Mode"
  358.      FREE
  359.         INIT = JUMPER(1) LOC(1-8) 10101010
  360.         INIT = SOFTWARE(1) "16 Bit Mode selected"
  361.       CHOICE = "8 Bit Mode"
  362.      FREE
  363.         INIT = JUMPER(1) LOC(1-8) 01010101
  364.         INIT = SOFTWARE(1) "8 Bit Mode selected"
  365.  
  366.    SUBFUNCTION = "Network Interface"
  367.       HELP = "
  368.  Select 10BASE-2 (BNC connector) if you are using
  369.  Cheapernet. Select 10BASE-5 (DIX connector) if
  370.  you are using the AUI port and an external transceiver."
  371.       
  372.       CHOICE = "10BASE-2 (BNC connector)"
  373.     FREE
  374.         INIT = JUMPER(2) LOC (1-8) 11111111
  375.         INIT = JUMPER(3) LOC (1-8) 00000000
  376.         INIT = SOFTWARE(1) "BNC connected"
  377.  
  378.       CHOICE = "10BASE-5 (DIX/AUI connector)"
  379.      FREE
  380.         INIT = JUMPER(2) LOC (1-8) 00000000 