home *** CD-ROM | disk | FTP | other *** search
/ OS/2 Shareware BBS: OtherApp / OtherApp.zip / papos2.zip / README.TXT < prev   
Text File  |  1998-10-13  |  10KB  |  173 lines

  1.  
  2. -------------------------------------------------
  3.   PowerAlert Plus Installation - Version 10.1
  4.   README File
  5. -------------------------------------------------
  6.                                     
  7.   This README file contains the latest information available for installing 
  8.   the PowerAlert Plus Product for OS/2.  The PowerAlert Plus Product consists 
  9.   of several different applications designed to monitor and control Tripp Lite 
  10.   UPS products.  
  11.  
  12.   The UPS utilities included in this package are:
  13.  
  14.   PAPLUS.EXE         The PowerAlert Plus OS/2 Client executable.  
  15.   PASERVER.EXE       The PowerAlert Plus OS/2 Server executable.  
  16.   SRVSETUP.EXE       Server Setup Application.
  17.   SHUTDOWN.EXE       Remote Shutdown Utility.
  18.  
  19.   This file contains helpful hints and instructions for installing the OS/2 
  20.   PowerAlert Plus Product.  This README file is the only source of information 
  21.   for installation issues that ships with the Product CD ROM.  Please check our 
  22.   website at http://www.tripplite.com for additional information regarding 
  23.   any problems identified in the product and their solutions.
  24.  
  25.  
  26.  
  27.   CONTENTS
  28.   --------
  29.  
  30.   This README file includes the following information:
  31.  
  32.  
  33.    1.0   Installation of the PowerAlert Plus for OS/2 Product
  34.    2.0   Installation Notes                                     
  35.    3.0   Sharing PowerAlert Plus Directories                                   
  36.    4.0   New Features of the PowerAlert Plus for OS/2 Product 
  37.    5.0   Technical Support                            
  38.  
  39.  
  40.    1.0  Installation of the OS/2 Product 
  41.         --------------------------------
  42.  
  43.         To install PowerAlert Plus for OS/2, open an OS/2 command prompt 
  44.         window (either FullScreen or Windowed) from the Command Prompts 
  45.         folder, then perform the following:
  46.         
  47.         * Switch to the drive and directory containing the OS/2 installation 
  48.           program on the Tripp Lite PowerAlert Plus CDROM for example: 
  49.    
  50.              X:\OS2.                (where X: is your CDROM drive)
  51.           
  52.         * Then run the PowerAlert Plus installation software by typing 
  53.           INSTALL at the X:\OS2 prompt.
  54.           
  55.         * If you attempt to access the installation program from an 
  56.           alternate directory for example:
  57.           
  58.           C:\> X:\OS2\INSTALL  
  59.           
  60.           the PowerAlert Plus installation will not work.  The installation 
  61.           program needs to be run from the actual OS2 directory on the 
  62.           CDROM.  
  63.           
  64.         * Alternately, you may use the Workplace Shell to start the 
  65.           installation program.  To do this, use the drives folder and 
  66.           locate the OS2 directory on the Tripp Lite PowerAlert Plus 
  67.           CDROM using the CDROM drive object.  Then double click on 
  68.           the INSTALL.EXE program to begin the installation of the 
  69.           PowerAlert Plus product.
  70.  
  71.  
  72.    2.0  Installation Notes 
  73.         ------------------
  74.         
  75.         * OS/2 systems no longer require a network interface card (NIC) to run the
  76.           OS/2 PowerAlert Plus product.  Therefore, you no longer need to have IBM 
  77.           Lan Requester or IBM Lan Server installed to run any of the PowerAlert Plus                                    
  78.           products and utilities.  However, networking is required for the Remote                                    
  79.           Shutdown Client and for using Network Alert Logging.                                                       
  80.                                                                                                            
  81.         * The PowerAlert Plus OS/2 software does require TCPIP to be installed and                                   
  82.           properly configured.  TCPIP can be installed either by installing the                                      
  83.           Internet Connection package that comes on the OS/2 Warp Bonuspak that                                      
  84.           ships with OS/2 Warp Version 3 or by using the TCPIP software that comes                                   
  85.           shipped with OS/2 Warp Version 4 or OS/2 Warp Connect.                                                     
  86.                                                                                                            
  87.           Without proper TCPIP support installed, the OS/2 Workplace Shell                                           
  88.           will display an error when attempting to run a PowerAlert Plus                                             
  89.           executable.                                                                                                
  90.                                                                                                            
  91.           The error will look like the following:                                                                    
  92.                                                                                                            
  93.           Cannot start                                                                                               
  94.              C:\PAPLUS\SERVER\PASERVER.EXE                                                                            
  95.                                                                                                            
  96.           Make sure the path for the program is correct and the file is                                              
  97.           an OS/2 or DOS program.  There might not be enough memory                                                  
  98.           available to run the program or the file may be locked by                                                  
  99.           another process.  Do you wish to modify the properties for                                                 
  100.           the object, PowerAlert Plus Server?                                                                        
  101.                                                                                                            
  102.           This error is caused by the fact that PowerAlert Plus Server                                               
  103.           requires the use of TCPIP dynamic link libraries.
  104.                                                                                                            
  105.         * Network Alert Logging functionality will not work when specifying 
  106.           a TCPIP address as the Server name in the PowerAlert Plus Client.  
  107.           The PowerAlert Plus Client will automatically display a message box 
  108.           indicating this information when the user enters a TCPIP address.                                   
  109.           To properly use the Network Alert Logging functionality, the user 
  110.           must use the computer name specified in the HOSTS file located in 
  111.           the MPTN\ETC directory.  To configure TCPIP in OS/2, run the 
  112.           program TCPCFG.EXE in the TCPIP\BIN directory.
  113.  
  114.  
  115.    3.0  Sharing PowerAlert Plus Directories   
  116.         -----------------------------------
  117.  
  118.         * In previous releases of the PowerAlert Plus OS/2 software, you 
  119.           were prompted during the installation to create the PowerAlert
  120.           Plus Share Names.  The Installation program automatically  
  121.           created and executed an OS/2 command file named SHARE.CMD which 
  122.           created the following shares:
  123.  
  124.              net share PAPLUS=X:\PAPLUS      
  125.              net share PAPLUSNA=X:\PAPLUS\NETALERT                                 
  126.  
  127.           The Share Names are used if you have IBM Lan Requester installed
  128.           and would like to take advantage of a shared directory to store 
  129.           PowerAlert Plus Network Alert Data.  The current release of 
  130.           the Installation program no longer creates this file.  Instead, 
  131.           the PowerAlert Plus Server automatically attempts to create 
  132.           the shares when it is started.  You may want to ensure that 
  133.           that Lan Requester is started and that you are logged on prior 
  134.           to launching the PowerAlert Plus Server to ensure that the 
  135.           directories are shared, and that you are able to take advantage
  136.           of this functionality.
  137.  
  138.  
  139.    4.0  New Features of the PowerAlert Plus for OS/2 Product 
  140.         ----------------------------------------------------
  141.  
  142.         * There are several new features that have been added to the  
  143.           PowerAlert Plus OS/2 product.  
  144.  
  145.           - The PowerAlert Plus OS/2 Server is now a 32 bit OS/2 Presentation 
  146.             Manager (PM) program.  The program uses the Stern & Morrow Software 
  147.             Process Information Tool Dynamic Link Library (PAPITAPI.DLL) to 
  148.             obtain information about processes running on the machine.  When a 
  149.             UPS shutdown occurs, a listing of all the running processes at the 
  150.             time of the shutdown is logged and is displayed by the PowerAlert 
  151.             Plus Server the next time it is started.  This allows administrators
  152.             to track UPS Shutdowns/Server Outtages and know for sure what was 
  153.             running at the time of the UPS Shutdown, so that they may restart 
  154.             programs if necessary.
  155.  
  156.    5.0  Contacting Tripp Lite
  157.         ---------------------
  158.         
  159.         * There are several ways that you can contact Tripp Lite to 
  160.           receive information on our latest products and updates to the 
  161.           PowerAlert Plus software.   
  162.           
  163.           General Info.......: 1-773-869-1111
  164.           Technical Support .: 1-773-869-1234
  165.  
  166.  
  167.           Or visit the Tripp Lite's PowerZone on the Internet:
  168.  
  169.           World Wide Web address: http://www.tripplite.com
  170.  
  171.  
  172.   (C) Copyright Tripp Lite Manufacturing 1998.  All rights reserved.
  173.