home *** CD-ROM | disk | FTP | other *** search
/ OS/2 Shareware BBS: 29 Fixes_o / 29-Fixes_o.zip / os2pt2.exe / NWREQOS2.MSG (.txt) < prev    next >
OS/2 Message File  |  1997-12-05  |  17KB  |  129 lines

  1. MKMSGF
  2. nwreqos2.msg
  3. IVeRsIoN=2.12
  4. ICoPyRiGhT=CopyRight (C) Novell, Inc. 1992-1996.  All Rights Reserved.
  5. EThe daemon cannot access the Link Support Layer.
  6. INetWare Client for OS/2 v2.12
  7. IPROTOCOL OPTION: Novell IPX
  8. I(C) Copyright 1988-1996 Novell, Inc.  All Rights Reserved.
  9. EThe system does not have enough memory for for socket tables.EThe LAN support module could not be installed.EThe IPX MLID could not be installed.EThe configured LAN-A driver does not support IPX.EThe IPX protocol handler cannot be registered.EThe IPX entry point cannot be initialized.EAn internal error occurred. The IPX router socket cannot be opened.EAn internal error occurred. A router selector cannot be allocated.EThe system has insufficient memory to allocate a router.ERouter memory is exhausted.EAn internal error prevented CGroup variable initialization.                some internal variables.
  10. EAn internal error prevented DosHlp variable initialization.EIPX cannot register with OS/2 for PDD-to-VDD communications.EThe IPX device driver is not running.I
  11. ISocketsIRouter MemIProtocol Stack IPXISessionsIBindIDefaultIPrescanI
  12. WThe default protocol configuration option is not used for IPX.WThe prescan protocol configuration option is not used for IPX.WThe OS/2 version number cannot be found; OS/2 v2.x is assumed.I
  13. I    Sockets: %1
  14. I    Router Memory: %1
  15. INetWare Client for OS/2 v2.12
  16. INovell Link Support Layer
  17. I(C) Copyright 1988-1996 Novell, Inc. All Rights Reserved.
  18. EAn LSL error occurred. NET.CFG buffers are too big for ECB pool.EThe Link Support module (LSL) could not install the AES timer.EThe Link Support module could not initialize its call gate.
  19. ILink SupportIBuffersIMem PoolI
  20. I    Buffers    : %1
  21. I    Buffer Size: %1
  22. I    Total Memory Allocated for Buffers: %1
  23. INetWare Client for OS/2 v2.12
  24. INovell NetBIOS Emulator
  25. I(C) Copyright 1988-1996 Novell, Inc. All Rights Reserved.
  26. ENetBIOS error occurred. Link Support module cannot be installed.
  27. ENetBIOS error occurred. The IPX module is not installed.
  28. EThe NetBIOS call gate cannot be initialized.
  29. ENetBIOS error occurred. The program cannot initialize local NCBs.
  30. ENetBIOS emulator parameters are too large for the memory pool.
  31. EIncompatible versions of OS/2 and NetBIOS are running.
  32. INetware NetBiosISessionsISend BuffersIRetry DelayIAbort TimeoutIVerify TimeoutIListen TimeoutIRetry CountICommandsIBroadcast DelayIBroadcast CountIInternetIOffIOnINamesIEmulate RedirectorIBindI
  33. EBIND Setting Failed,  NetBIOS bound to IPX's primary board.
  34. INetWare Client for OS/2 v2.12
  35. INovell Remote Named Pipes Driver
  36. I(C) Copyright 1990-1994 Novell, Inc. All Rights Reserved.
  37. EThe SPX module is not installed.EThe IPX module is not installed.E
  38. EAn incorrect OS/2 version is being used.EThe driver cannot register the PDD for VDD-to-PDD communications.I
  39. INamed PipesIClient SessionsIMachine NamesI
  40. INamed PipesI
  41. EInvalid characters were specified in COMPUTERNAME.
  42. EThe Named Pipes daemon could not open the NPSERVER.SYS driver.
  43. EThe Named Pipes daemon could not open the NMPIPE.SYS driver.
  44. EAn error occurred during attempt to allocate shared memory.
  45. EAn error occurred during attempt to create a system semaphore.
  46. EAn error occurred during attempt to create a thread.
  47. EA dynamic socket could not be opened.
  48. EA well-known socket could not be opened.
  49. EThe NPDaemon cannot get the Internet address.
  50. EThe NPDaemon cannot get the local target.
  51. EThe service advertising function failed.
  52. EThe broadcast socket cannot be opened.
  53. EA connection thread died abnormally.
  54. EThe specified computer name is already registered on the internet.
  55. EThe receive buffer manager died abnormally.
  56. EGeneral Service Query for Named Pipe Servers failed.
  57. EAn error occurred while obtaining the IPX card table.
  58. INetWare Client for OS/2 v2.12
  59. INovell Named Pipes Server
  60. I(C) Copyright 1990-1994 Novell, Inc. All Rights Reserved.
  61. EThe SPX module is not installed.EThe IPX module is not installed.E
  62. EAn incorrect OS/2 version is being used.E
  63. INamed PipesIServer SessionsIAdvertise BoardI
  64. EThe Requester device driver and daemon are incompatible versions.
  65. EThe worker DLL cannot be registered.
  66. EThe broadcast handler cannot be registered.
  67. EThe janitor thread priority cannot be set.
  68. EThe janitor daemon cannot be registered.
  69. EThe program cannot get the current drive map.
  70. EThe program cannot set the current drive map.
  71. EThe program cannot get the connection ID.
  72. EAn error occurred during attempt to initialize the cache.
  73. EThe daemon could not boost the thread priority.
  74. EThe daemon could not register the DosBox handler.
  75. ENot enough memory for diagnostic daemon.
  76. EThe diagnostic daemon cannot be started.
  77. EThe diagnostic daemon priority cannot be changed.
  78. ENot enough system memory to start a new thread.
  79. EThe SPX send thread cannot be started.
  80. EThe SPX receive thread cannot be started.
  81. EThe SFT 3 handler cannot be registered.
  82. EPacket Burst cannot be initialized.
  83. INo RAMIRAM = INo IRQIIRQ = INo DMAIDMA Line = INetWare IOS/2IIBMPCI
  84. ENot enough memory for a network management thread (%1).
  85. EA named pipe cannot be started for network management (%1).
  86. ENot enough system memory to run network management (%1).
  87. INetWare Client for OS/2 v2.12
  88. INovell IFS Requester
  89. I(C) Copyright 1988-1996 Novell, Inc. All Rights Reserved.
  90. EThe NWREQ.SYS driver is not loaded.E
  91. EThe program cannot allocate selectors for the workspace table.EThe program cannot allocate memory for the workspace table.E
  92. EAn incorrect OS/2 version is being used.E
  93. INetWare RequesterICache BuffersITrue CommitI
  94. EThe Requester driver version does not match the IFS version.E
  95. INetWare Client for OS/2 v2.12
  96. INovell IFS Driver
  97. I(C) Copyright 1988-1996 Novell, Inc. All Rights Reserved.
  98. IPatent No. 5,349,642.
  99. EThe LAN support module is not installed.E
  100. WA NetWare server cannot be found.I
  101. EThe program cannot allocate selectors for the connection table.EThe program cannot allocate memory for the connection table.E
  102. EAn incorrect OS/2 version is being used.E
  103. WThe config file cannot be parsed. Default parameters will be used.EAn unrecoverable error occurred. The driver was not loaded.E
  104. EThe program cannot allocate selectors for worker support.I    Connections:       %1 connections
  105. I    Retry count:       %1 retries
  106. IConfigured for a nondedicated NetWare file server.
  107. INetWare RequesterI
  108. ISessionsIRequest RetriesIPreferred ServerIRequester TypeIDefault Login DriveIDisplay Hard Errors OffEThe program cannot allocate memory for the error message buffer.EThe Requester could not send to server %1 as %2.EThe Requester timed out waiting for reply from server %1.EServer %1 did not respond to a request.EConnection to NetWare server %1 as %2 is now invalid.ERouting to NetWare server %1 has been disrupted.E
  109. INonded ServerIDirectory Services OffIName ContextIPacket Burst OffISignature LevelIPreferred TreeILarge Internet Packets OffIDisconnect OnILarge Internet Packets NegotiatedE
  110. EThe SPDaemon cannot get the SPX version.
  111. EThe SPX driver and the SPX daemon are incompatible versions.
  112. EThe SPX driver entry cannot be obtained.
  113. EThe SPX daemon is already loaded.
  114. EThe daemon cannot register with the SPX driver.
  115. EPriority for an SPX daemon thread cannot be set.
  116. EThe SPX driver cannot be accessed.
  117. INetWare Client for OS/2 v2.12
  118. IPROTOCOL OPTION: Novell SPX
  119. I(C) Copyright 1988-1996 Novell, Inc.  All Rights Reserved.
  120. EThe driver cannot initialize the CGroup Data variables.EThe driver cannot configure SPX.EThe driver failed to get support hooks from the LSL or IPX.EThe OS/2 version cannot be obtained; OS/2 v2.x is assumed.EThe driver cannot get OS/2 DOS variables.EThe driver cannot initialize the SPX call gate.EThe driver cannot allocate memory for SPX use.E
  121. IAbort TimeoutIListen TimeoutIProtocol Stack SPXIRetry CountISessionsIVerify TimeoutILock AliasIPacket RouteIIPXIDynamicISend TimeoutI
  122. I    Abort timeout:     %1 milliseconds
  123. I    Listen timeout:    %1 milliseconds
  124. I    Retry count:       %1 retries
  125. I    Sessions:          %1 sessions
  126. I    Verify timeout:    %1 milliseconds
  127. I    Total memory used: %1 bytes
  128. EThe application cannot initialize named pipes.E
  129.