home
***
CD-ROM
|
disk
|
FTP
|
other
***
search
/
OS/2 Shareware BBS: 21 PDrivers
/
21-PDrivers.zip
/
AESVER21.ZIP
/
4019AES.MSG
(
.txt
)
< prev
next >
Wrap
OS/2 Message File
|
1991-08-05
|
3KB
|
53 lines
MKMSGF
IIBM Laserprinter 4019 AES code for OS/2I(C)Copyright IBM Corp., 1989,1991ILicensed Material - Program Property of IBMIVersion 2.1I:
ENot enough parameters specified on the command line.
EFirst character of a parameter doesn't begin with a /.
EThe /R option should be the only parameter.
E"%1" invalid. Valid values are /LPT1, /LPT2, /LPT3.
E"%1" invalid. Valid values are /COM1, /COM2, /COM3.
EConfiguration file name can only have 80 characters in it.
EConfiguration file name format is /F=FILENAME.EXT.
EIllegal hexidecimal string in mode switch command.
ENot an even number of ASCII characters to convert to hex.
ELast character of hex data wasn't a single quote (').
EDosSemSet failed with RC = %1.
EUnable to set PIPE semaphore. RC = %1.
EMonitor Open on %1 failed with RC = %2.
EMonitor Register on %1 failed with RC = %2.
EUnable to open AVAIL semaphore. RC = %1.
EError allocating stack for %1 thread. RC = %2.
EError creating %1 thread. RC = %2.
ESemaphore create failed with RC = %1.
EUnable to wait for PIPE semaphore. RC = %1.
EUnable to get control back from monitors. RC = %1.
EUnable to read pipe from new instance of AES. RC = %1.
EUnable to write pipe to new instance of AES. RC = %1.
EUnable to OPEN device %1. RC = %2.
EDosMakeNMPipe failed. rc = %1.
EDosOpenSem failed with RC = %1.
EUnable to clear PIPE semaphore. RC = %1.
EDosConnectNMPipe failed. RC = %1.
EDosDisConnectNMPipe failed. rc = %1.
EDosOpen failed on file "%1".
EError closing file "%1". RC = %2.
EDosSetPrty failed. RC = %1.
E%1 - Unable to get monitor packet from the chain. RC = %2.
E%1 - Unable to send monitor packet down the chain. RC = %2.
E%1 - Unable to request semaphore. RC = %2.
E%1 - Unable to clear semaphore. RC = %2.
E%1 - Unable to write data. RC = %2.
EInvalid option "%1".
EFormat is /T=y (to enable timeout) or /T=n (to disable timeout).
EError in DosGetVersion RC = %1.
EIncorrect OS/2 Version.
E%1 - Only %2 of %3 bytes written.
E4019AES program already running. Use /R option to end program.
EThe output port must be a member of the configuration file.
EToo many devices specified in configuration file.
EThe /I option should be the only parameter.
EFormat is /S=y (to enable data shifting) or /T=n (to disable data shifting).
I4019AES program is running.
IFCOMAESI4019AES %1,%2EReturn code %2 returned trying to open %1.
IThe physical port is %1IThe Baud rate is %1IYou are about to end the 4019AES program. Make sure all printing has completed and the spooler is idle.
E/P%1 is an invalid option.