MKMSGF
6&7R9";
B?
?
?
ICause: An unexpected error occurred when the
program attempted to open the microcode file.
User Action: Check the drive and directory to ensure that
the microcode file exists. Check the microcode file name
specified in PROTOCOL.INI to ensure that it is correct.
If the problem persists, reinstall the microcode file in
the proper directory.
ICause: An unexpected error occurred when the
program attempted to read the microcode file.
User Action: Reinstall the microcode file in the proper
directory.
ICause: An unexpected error occurred when the
program attempted to open the bootstrap file.
User Action: Check the drive and directory to ensure that
the bootstrap file exists. Check the bootstrap file name
specified in PROTOCOL.INI to ensure that it is correct.
If the problem persists, reinstall the bootstrap file in
the proper directory.
ICause: An unexpected error occurred when the
program attempted to read the bootstrap file.
User Action: Reinstall the bootstrap file in the proper
directory.
ICause: The value provided for the keyword in the
IBMTRBM module in PROTOCOL.INI is not the correct type.
User Action: Change the value in PROTOCOL.INI to
the correct type for the parameter.
ICause: An internal software error occurred.
User Action: Contact your vendor sales representative.
ICause: One or more IBM Token-Ring Network 16/4 Busmaster
Server Adapter/A adapters are set to a different interrupt level.
To function properly, these adapters must all be set to the
same interrupt level.
User Action: Use the reference diskette that came with your
computer to ensure that all IBM Token-Ring Network 16/4 Busmaster
Server Adapter/A adapters are set to the same interrupt level.
ICause: The bootstrap code was unable to load properly
onto the IBM Token-Ring Network 16/4 Busmaster Server
Adapter/A adapter.
User Action: Contact your vendor sales representative.
ICause: The bootstrap code was unable to load properly
onto the IBM Token-Ring Network 16/4 Busmaster Server
Adapter/A adapter.
User Action: Contact your vendor sales representative.
ICause: The 80286 processor is not supported for this
version of the device driver.
User Action: Either install the 80286 version of the
device driver on this machine or remove the statement
that installs the device driver from CONFIG.SYS.
ICause: The parameters specified require more space for processing
than can be handled. The maximum allowable control-block size
is 64KB.
User Action: Reduce the value specified for the SIZWORKBUF
or MINRCVBUFFS parameter to change the amount of storage
required for the control-blocks.
ICause: The adapter is not responding to a request to load
the bootstrap code.
User Action: Run the hardware diagnostics for the IBM Token-Ring
Network 16/4 Busmaster Server Adapter/A adapter. Contact
your vendor sales representative.
ICause: The adapter is not responding to a request to load
the bootstrap code.
User Action: Run the hardware diagnostics for the IBM Token-Ring
Network 16/4 Busmaster Server Adapter/A adapter. Contact
your vendor sales representative.
ICause: The adapter is not responding to a request to run
the bootstrap code.
User Action: Run the hardware diagnostics for the IBM Token-Ring
Network 16/4 Busmaster Server Adapter/A adapter. Contact
your vendor sales representative.
ICause: The adapter is not responding to a request to run
the bootstrap code.
User Action: Run the hardware diagnostics for the IBM Token-Ring
Network 16/4 Busmaster Server Adapter/A adapter. Contact
your vendor sales representative.
ICause: The bootstrap code was unable to load properly
onto the IBM Token-Ring Network 16/4 Busmaster Server
Adapter/A adapter.
User Action: Run the hardware diagnostics for the IBM Token-Ring
Network 16/4 Busmaster Server Adapter/A adapter. Contact
your vendor sales representative.
ICause: The microcode was unable to load properly
onto the IBM Token-Ring Network 16/4 Busmaster Server
Adapter/A adapter.
User Action: Contact your vendor sales representative.
ICause: The microcode was unable to write properly
to the IBM Token-Ring Network 16/4 Busmaster Server
Adapter/A adapter.
User Action: Contact your vendor sales representative.
ICause: The adapter is not responding to a request to initialize
the microcode.
User Action: Run the hardware diagnostics for the IBM Token-Ring
Network 16/4 Busmaster Server Adapter/A adapter. Contact
your vendor sales representative.
ICause: The adapter is not responding to a request to run
the microcode.
User Action: Run the hardware diagnostics for the IBM Token-Ring
Network 16/4 Busmaster Server Adapter/A adapter. Contact
your vendor sales representative.
ICause: The burned-in address on the adapter could not be located.
User Action: Either use the set network address (NETADDRESS)
parameter in PROTOCOL.INI to override the burned-in address or
run the hardware diagnostics for the IBM Token-Ring Network
16/4 Busmaster Server Adapter/A adapter and contact your
vendor sales representative.
ICause: Only one occurrence of the device driver statement
for the IBM Token-Ring Network 16/4 Busmaster Server Adapter/A
NDIS MAC device driver is required to support multiple adapters.
Additional instances of the device driver statement in CONFIG.SYS
will be ignored.
User Action: Remove the duplicate device driver statements from
CONFIG.SYS.
ICause: The parameter specifying the driver name (DRIVERNAME) was not
found in PROTOCOL.INI. This parameter is required.
User Action: Change PROTOCOL.INI to specify the proper information.
ICause: An unexpected error occurred when the
program attempted to open the protocol manager.
The IBM Token-Ring Network 16/4 Busmaster Server Adapter/A
NDIS MAC device driver has been removed.
User Action: Check the drive and directory to ensure that
the protocol manager is located in the specified path.
ICause: The device driver was unable to register with
the protocol manager.
User Action: Reinstall the protocol manager and
try the operation again.
ICause: There was no adapter found in this machine.
IBM Token-Ring Network 16/4 Busmaster Server Adapter/A adapters
are required to run the MAC device driver.
User Action: Install an IBM Token-Ring Network 16/4 Busmaster
Server Adapter/A adapter in this machine, or remove the device
driver statement from CONFIG.SYS.
ICause: An unrecognized parameter was found
while processing the IBM Token-Ring Network 16/4 Busmaster
Server Adapter/A section of PROTOCOL.INI.
User Action: Correct the parameter or remove it from
PROTOCOL.INI.
ICause: The value specified for the network address parameter in
PROTOCOL.INI is not valid for one of the following reasons:
- Invalid local station address
- Too long
- Too short
- Contains non-hexadecimal characters
- Not enclosed in double quotes
User Action: Remove or correct the network address parameter
(NETADDRESS). A valid value for this parameter is 12 characters
long, is enclosed in double quotes, and contains only valid
hexadecimal characters within the range of 400000000000 through
40007FFFFFFF.
?
ICause: The network address that the adapter wants to use on the
token-ring is being used by another node.
User Action: Either modify PROTOCOL.INI to provide a different
value for the network address (NETADDRESS) parameter, use the
default burned-in address, or remove the other node that is
using this network address from the ring.
ICause: The ring speed is different from the speed of the
node attempting to insert onto the ring.
User Action: Use the reference diskette that came with your
computer to ensure that the adapter is configured at the same
speed as the token-ring.
ICause: When the adapter tried to insert onto the token-ring, a
hardware error occurred on the adapter.
User Action: Run the hardware diagnostics for the IBM Token-Ring
Network 16/4 Busmaster Server Adapter/A adapter. Contact
your vendor sales representative.
ICause: While attempting to open the adapter, an indication
was received that the adapter is not properly connected to
the token-ring.
User Action: Ensure that the token-ring cable is connected to
the adapter and to the token-ring multistation access unit (MAU).
If the error persists, use a different token-ring cable
and check to ensure that the connection to the MAU is
functioning properly. Then run the hardware diagnostics
for the IBM Token-Ring Network 16/4 Busmaster Server Adapter/A
adapter.
ICause: The version of the IBM Token-Ring Network 16/4
Busmaster Server Adapter/A NDIS MAC device driver is
built for an 80286 machine. The version will function
correctly on this 80386/80486 machine, but performance
benefits will not be available.
User Action: Install the optimized version on this machine.
ICause: The device driver installed is designed to run on
a different operating system.
User Action: Do the following:
1. Locate the current version of IMBTRBM.OS2 on the machine.
2. Erase IBMTRBM.OS2.
3. Copy IBMTRBM.286 from the installation diskette into the directory.
4. Rename IBMTBM.286 to IBMTRBM.OS2.
5. Restart your system.