home *** CD-ROM | disk | FTP | other *** search
/ OS/2 Shareware BBS: 8 Other / 08-Other.zip / e52os2m.exe / nfserial.hlp (.txt) < prev    next >
OS/2 Help File  |  1998-05-27  |  13KB  |  398 lines

  1.  
  2. ΓòÉΓòÉΓòÉ 1. Netfinity Serial Connection Control ΓòÉΓòÉΓòÉ
  3.  
  4. Use the Netfinity Serial Connection Control window to: 
  5.  
  6.    o  Apply to add or change a serial connection entry 
  7.  
  8.    o  Change the name of a serial connection entry 
  9.  
  10.    o  Delete a serial connection entry 
  11.  
  12.    o  Start a serial connection 
  13.  
  14.    o  Change the Modem Settings 
  15.  
  16.    o  Exit this service 
  17.  
  18.  
  19. ΓòÉΓòÉΓòÉ 2. Name ΓòÉΓòÉΓòÉ
  20.  
  21. Use the Name field to assign a unique name to the Serial Connection Control 
  22. entry that you are creating for an individual system.  For example, the System 
  23. Name of the system that you are configuring for Serial Connection access would 
  24. be a good entry.  However, the Name entry is purely descriptive, and can be 
  25. anything at all. 
  26.  
  27.  
  28. ΓòÉΓòÉΓòÉ 3. Number ΓòÉΓòÉΓòÉ
  29.  
  30. Type in the Number field the telephone number of the system that you want to 
  31. use Serial Connection Control to access. 
  32.  
  33. Note:   The system that you are dialing in to must be in AutoAnswer mode for a 
  34. connection attempt to be successful. 
  35.  
  36. Note:   If you are configuring a null modem communications session, the caller 
  37. must put a "dummy" number (any series of numerals) in this field.  The system 
  38. receiving the call must leave this field blank. 
  39.  
  40.  
  41. ΓòÉΓòÉΓòÉ 4. COM Port ΓòÉΓòÉΓòÉ
  42.  
  43. Set the COM Port field to the number of the COM Port that will be used to dial 
  44. out to the remote system.  Because any modem can be attached to any COM Port, 
  45. be sure that the modem settings that will be used are properly configured. 
  46.  
  47.  
  48. ΓòÉΓòÉΓòÉ 5. Baud Rate ΓòÉΓòÉΓòÉ
  49.  
  50. Set the Baud Rate field to the data transfer rate that will be used by the 
  51. modem during communications between your system and the remote Netfinity system 
  52. that you access. 
  53.  
  54. Note:   Many modems have built-in data compression, and therefore are capable 
  55. of transmitting data at a rate higher than which they are rated for.  You 
  56. should set the Baud Rate as high as will permit a successful connection. 
  57.  
  58. Note:   Setting the Baud Rate lower than your modem's rating will force a lower 
  59. data transmission rate.  This may be neccessary if telephone line conditions 
  60. are poor. 
  61.  
  62.  
  63. ΓòÉΓòÉΓòÉ 6. User ID ΓòÉΓòÉΓòÉ
  64.  
  65. Type in the User ID field the User ID that, when used in conjunction with a 
  66. Password will enable you to access the remote system that you are dialing in 
  67. to. 
  68.  
  69. Note:   You must provide a User ID and a Password that matches the User ID and 
  70. Password on the remote systems Serial Connection Control for the Serial 
  71. Connection Control to allow access to a remote system.  Once connected, all 
  72. normal Security Manager rules apply for access to both local and remote 
  73. systems. 
  74.  
  75.  
  76. ΓòÉΓòÉΓòÉ 7. Password ΓòÉΓòÉΓòÉ
  77.  
  78. Type in the Password field the Password that, when used in conjunction with a 
  79. User ID will enable you to access the remote system that you are dialing in to. 
  80.  
  81. Note:   You must provide a User ID and a Password that matches the User ID and 
  82. Password on the remote systems Serial Connection Control for the Serial 
  83. Connection Control to allow access to a remote system.  Once connected, all 
  84. normal Security Manager rules apply for access to both local and remote 
  85. systems. 
  86.  
  87.  
  88. ΓòÉΓòÉΓòÉ 8. Auto Start ΓòÉΓòÉΓòÉ
  89.  
  90. Select the Auto Start checkbox to enable one selected Serial Connection Control 
  91. entry to be activated automatically when Netfinity is started.  Only one entry 
  92. can be set to start automatically. 
  93.  
  94. For example, if you select the AutoAnswer entry from the Name field, and then 
  95. select the Auto Start checkbox, this system will automatically go into 
  96. AutoAnswer mode when Netfinity is started.  This would enable other Netfinity 
  97. Manager's to use their own Serial Connection Control services to dial into your 
  98. system.  However, if you selected a Serial Connection Control entry that 
  99. enables you to dial into another system and then selected the Auto Start 
  100. checkbox, your system would automatically attempt to access the remote system 
  101. when Netfinity was started. 
  102.  
  103.  
  104. ΓòÉΓòÉΓòÉ 9. Null Modem ΓòÉΓòÉΓòÉ
  105.  
  106. Select the Null Modem checkbox to allow serial communications over a null modem 
  107. connection, such as a direct connection between two systems using their serial 
  108. ports. 
  109.  
  110. To set up a null modem serial connection: 
  111.  
  112.    o  On the calling (or managing) system: 
  113.  
  114.         1. Type in the Name field a name for the connection. 
  115.  
  116.         2. Type in the Number field a "dummy" telephone number. 
  117.  
  118.            Note:   You must provide a number in this field for the null modem 
  119.            connection to funstion properly.  The "dummy" number must consist of 
  120.            at least one digit. 
  121.  
  122.         3. Set the Baud Rate. 
  123.  
  124.            Note:   The baud rate must be the same for both the calling and the 
  125.            receiving system. 
  126.  
  127.         4. Select the COM Port for the null modem connection that will be used 
  128.            to access the remote system. 
  129.  
  130.         5. Type in a User ID that will allow access to the remote system. 
  131.  
  132.         6. Type in a Password that will allow access to the remote system. 
  133.  
  134.         7. Select the Null Modem checkbox. 
  135.  
  136.         8. Select Apply to save this entry. 
  137.  
  138.    o  On the receiving system: 
  139.  
  140.         1. Select Auto Answer from the Name field. 
  141.  
  142.         2. Leave the Number field blank. 
  143.  
  144.            Note:   The Number field must be blank for the null modem connection 
  145.            to function properly. 
  146.  
  147.         3. Set the Baud Rate. 
  148.  
  149.            Note:   The baud rate must be the same for both the calling and the 
  150.            receiving system. 
  151.  
  152.         4. Select the COM Port for the null modem connection that will be used 
  153.            to access the remote system. 
  154.  
  155.         5. Type in a User ID that will allow access to the system. 
  156.  
  157.         6. Type in a Password that will allow access to the system. 
  158.  
  159.         7. Select the Null Modem checkbox. 
  160.  
  161.         8. Select Apply to save this entry. 
  162.  
  163.  Select Start to initiate the null modem connection from the managing system or 
  164.  to instruct the receiving system to begin waiting for a null modem connection. 
  165.  
  166.  
  167. ΓòÉΓòÉΓòÉ 10. Apply ΓòÉΓòÉΓòÉ
  168.  
  169. To add a new Serial Connection Control entry: 
  170.  
  171.    1. Assign a Name to the entry. 
  172.  
  173.    2. Type in the Number field the telephone number of the system that you will 
  174.       be accessing. 
  175.  
  176.    3. Select the COM Port of the modem that you will be using to access the 
  177.       remote system. 
  178.  
  179.    4. Select the Baud Rate of the modem that you will be using to access the 
  180.       remote system. 
  181.  
  182.    5. Type in a User ID that will allow access to the remote system. 
  183.  
  184.    6. Type in a Password that will allow access to the remote system. 
  185.  
  186.    7. Select Apply to save this entry. 
  187.  
  188.  Note:   If you are adding a null modem connection, see null modem connection 
  189.  information for instruction specific to null modem connections. 
  190.  
  191.  To change a previously configured Serial Connection Control entry: 
  192.  
  193.    1. Select from the Name field the name of the Serial Connection Control 
  194.       entry that you want to modify. 
  195.  
  196.    2. Modify the Serial Connection Control entry's settings as necessary. 
  197.  
  198.    3. Select Apply to save your changes. 
  199.  
  200.  
  201. ΓòÉΓòÉΓòÉ 11. Change Name ΓòÉΓòÉΓòÉ
  202.  
  203. To change the name of a Serial Connection Control entry: 
  204.  
  205.    1. Select from the Name field the name of the Serial Connection Control 
  206.       entry that you want to change. 
  207.  
  208.    2. Select Change Name. 
  209.  
  210.    3. Type in the New Name the new name for the selected entry. 
  211.  
  212.    4. Select OK to save the new name and close the Change Name window. 
  213.  
  214.  Select Cancel to close the Change Name window without saving any changes. 
  215.  
  216.  
  217. ΓòÉΓòÉΓòÉ 12. New Name ΓòÉΓòÉΓòÉ
  218.  
  219. Type in this field the new name for the Serial Connection Control entry. 
  220.  
  221.  
  222. ΓòÉΓòÉΓòÉ 13. OK ΓòÉΓòÉΓòÉ
  223.  
  224. Select  to change the name of the Serial Connection Control entry. 
  225.  
  226.  
  227. ΓòÉΓòÉΓòÉ 14. Cancel ΓòÉΓòÉΓòÉ
  228.  
  229. Select Cancel to close this window without changing the name of the Serial 
  230. Connection Control entry. 
  231.  
  232.  
  233. ΓòÉΓòÉΓòÉ 15. Delete ΓòÉΓòÉΓòÉ
  234.  
  235. To delete a Serial Connection Control entry: 
  236.  
  237.    1. Select from the Name field the Serial Connection Control entry that you 
  238.       want to delete. 
  239.  
  240.    2. Select Delete to delete the selected entry. 
  241.  
  242.  
  243. ΓòÉΓòÉΓòÉ 16. Start ΓòÉΓòÉΓòÉ
  244.  
  245. Select Start to intitiate the currently selected Serial Connection Control 
  246. entry. If the currently selected entry is AutoAnswer, the Serial Connection 
  247. Control service will wait for a remote Netfinity Manager to attempt to access 
  248. the system via the modem.  If the currently selected entry is a configured 
  249. remote system access entry, the Serial Connection Control will initialize the 
  250. modem, dial the specified telephone number, and attempt to connect to the 
  251. remote system. 
  252.  
  253. Note:   If Stop is displayed, select Stop to end the current connection. This 
  254. will hangup and reset the modem.  If the service was waiting for a call, this 
  255. will disable AutoAnswer and reset the modem. 
  256.  
  257.  
  258. ΓòÉΓòÉΓòÉ 17. Modem Settings ΓòÉΓòÉΓòÉ
  259.  
  260. Select Modem Settings to configure this system's modem for use with the 
  261. Netfinity Serial Connection service.  One modem can be configured to be used on 
  262. each of up to four COM Ports. 
  263.  
  264.  
  265. ΓòÉΓòÉΓòÉ 18. Exit ΓòÉΓòÉΓòÉ
  266.  
  267. Select Exit to close the Netfinity Serial Connection Control window and exit 
  268. this service. 
  269.  
  270.  
  271. ΓòÉΓòÉΓòÉ 19. Netfinity Modem Settings ΓòÉΓòÉΓòÉ
  272.  
  273. Use the Netfinity Modem Settings window to configure your system's modem for 
  274. use by the Serial Connection Control service, or to change previously saved 
  275. configuration information. 
  276.  
  277. To configure your system's modem: 
  278.  
  279.    1. Select the COM Port for the modem that you are configuring. 
  280.  
  281.    2. Select a Modem Name, or type in a new one. 
  282.  
  283.       Note:   Selecting a preconfigured Modem Name or Default will 
  284.       automatically fill in the other modem configuration information. 
  285.  
  286.    3. Type in the proper Initialization String for your system's modem. 
  287.  
  288.    4. Type in the proper Hangup String for your system's modem. 
  289.  
  290.    5. Select Save to save these settings and enable this modem to be used by 
  291.       the Serial Connection Control service. 
  292.  
  293.  To change previously configured modem settings: 
  294.  
  295.    1. Select from the Modem Name field the name of the modem that you want to 
  296.       modify. 
  297.  
  298.    2. Modify the modem's settings as necessary. 
  299.  
  300.    3. Select Save to save these changes and enable this modem to be used by the 
  301.       Serial Connection Control service. 
  302.  
  303.  
  304. ΓòÉΓòÉΓòÉ 20. COM Port ΓòÉΓòÉΓòÉ
  305.  
  306. Use the spin buttons beside the COM Port field to select the modem's COM port. 
  307.  
  308.  
  309. ΓòÉΓòÉΓòÉ 21. Modem Name ΓòÉΓòÉΓòÉ
  310.  
  311. Select from the Modem Name field the name of your system's modem, or type in a 
  312. new one.  If you do not know what kind of modem your system has, select 
  313. Default. 
  314.  
  315. Note:   Selecting a preconfigured Modem Name or Default will automatically fill 
  316. in the other modem configuration information. 
  317.  
  318.  
  319. ΓòÉΓòÉΓòÉ 22. Initialization String ΓòÉΓòÉΓòÉ
  320.  
  321. Type in the Initialization String field an initialization string that will 
  322. enable your modem to function properly with the Serial Connection Control 
  323. service. For more information, see Initialization String Guidelines. 
  324.  
  325.  
  326. ΓòÉΓòÉΓòÉ 23. Initialization String Guidelines ΓòÉΓòÉΓòÉ
  327.  
  328.    o  Required Initialization Codes 
  329.  
  330.       Although most modems share similar initialization string codes, there are 
  331.       variances from modem to modem.  Therefore, it is very difficult to 
  332.       provide appropriate initialization strings for all modems.  In some cases 
  333.       you might need to create your own initialization string for your modem. 
  334.       In this case, consult the documentation that came with your modem for the 
  335.       appropriate initialization strings codes. 
  336.  
  337.       For a modem to operate correctly with the Netfinity Serial Connection 
  338.       Control service, the initialization string must configure the modem as 
  339.       follows: 
  340.  
  341.         -  Command echoing OFF 
  342.         -  On-line character echoing OFF 
  343.         -  Result codes ENABLED 
  344.         -  Verbal result codes ENABLED 
  345.         -  All codes and Connect messages with BUSY and DT detection 
  346.         -  Protocol identifiers added - LAPM/MNP/NONE V42bis/MNP5 
  347.         -  Normal CD operations 
  348.         -  DTR ON-OFF hangup, disable AA and return to command mode 
  349.         -  CTS hardware flow control 
  350.         -  RTS control of receive data to computer 
  351.         -  Queued and nondestructive break, no escape state 
  352.         -  Auto-answer off 
  353.  
  354.       Example:  The initialization string for a USRobotics Sportster modem 
  355.       using only the settings required for correct operation would be: 
  356.  
  357.       E0F1Q0V1X4&A3&C1&D2&H1&R2&Y3S0=0 
  358.  
  359.    o  Recommended Initialization Codes 
  360.  
  361.       In addition to the required initialization codes, you can optimize the 
  362.       operation of the Netfinity Serial Connection Control service by 
  363.       configuring your modem with the following additional settings: 
  364.  
  365.         -  Speaker ON until carrier detected 
  366.         -  Software flow control disabled 
  367.         -  Auto-error control 
  368.         -  Variable data rate 
  369.  
  370.       Example:  The initialization string for a USRobotics Sportster modem 
  371.       using all the required and recommended settings would be: 
  372.  
  373.       E0F1M1Q0V1X4&A3&C1&D2&H1&I0&K1&M4&N0&R2&Y3S0=0 
  374.  
  375.  
  376. ΓòÉΓòÉΓòÉ 24. Hangup String ΓòÉΓòÉΓòÉ
  377.  
  378. The Hangup String field contains the command that will be sent to the modem to 
  379. instruct it to close the connection to the phone line.  This string will 
  380. function properly on most modems.  If your modem does not respond correctly to 
  381. the default hangup string, please consult the documentation that came with your 
  382. modem for more information. 
  383.  
  384.  
  385. ΓòÉΓòÉΓòÉ 25. Save ΓòÉΓòÉΓòÉ
  386.  
  387. Select Save to save the currently displayed modem settings. 
  388.  
  389.  
  390. ΓòÉΓòÉΓòÉ 26. Delete ΓòÉΓòÉΓòÉ
  391.  
  392. Select Delete to delete the currently selected Modem Name and its settings. 
  393.  
  394.  
  395. ΓòÉΓòÉΓòÉ 27. Exit ΓòÉΓòÉΓòÉ