/* Rexx */
/* Sortiert die Datei CONFIG.SYS
Copyright (c) 1997 by Stefan Milcke
Fresenbergstraße 75
28779 Bremen
Dieses Rexx-Script ist Freeware
Datum der Erstellung: 03.07.1997
Letzte Aenderung am: 23.08.1998
*/
/* Vorgeplänkel */
CfgFile="\CONFIG.SYS"
TempCfg="\CONFIG.NEW"
Call RxFuncAdd 'SysLoadFuncs','RexxUtil','SysLoadFuncs'
Call RxFuncAdd 'SysFileDelete','RexxUtil','SysFileDelete'
Call RxFuncAdd 'SysTempFileName','RexxUtil','SysTempFileName'
/* CONFIG.SYS einlesen */
i=1
IFile=Stream(CfgFile,"C","OPEN READ")
Do Forever
If Lines(CfgFile)=0 Then Leave
CfgLine.i=Linein(CfgFile)
If (Left(CfgLine.i,20)="REM ****************") | (Left(CfgLine.i,6)="REM : ") Then
Nop
Else
i=i+1
CfgLine.0=i
End
IFile=Stream(CfgFile,"C","CLOSE")
/* ggf. Temporäre Datei löschen */
FileThere=Stream(TempCfg,"C","QUERY EXISTS")
If Length(FileThere)>0 Then
Call SysFileDelete TempCfg
/* Temporäre Datei öffnen */
OFile=Stream(TempCfg,"C","OPEN WRITE")
/* IFS einsortieren */
/* Zuerst einen Remark einfügen */
Call AddRemark "Installable File Systems (IFS)"
Call GetUnsorted "IFS"
Call WriteFoundArray
rc=LineOut(TempCfg,"")
/* Base Devices einsortieren */
Call AddRemark "Base Devices"
Call GetUnsorted "BASEDEV"
Call WriteFoundArray
rc=LineOut(TempCfg,"")
/* SET statements einsortieren */
Call AddRemark "Environment variables"
Call GetUnsorted "SET "
Call SortFoundArray
Call WriteFoundArray
rc=LineOut(TempCfg,"")
/* Devices einsortieren */
Call AddRemark "Devices"
Call GetUnsorted "DEVICE"
Call WriteFoundArray
rc=LineOut(TempCfg,"")
/* Alle bekannten OS/2 statements einsortieren */
Call AddRemark "OS2 Statements"
Call GetUnsorted "AUTOFAIL"
Call WriteFoundArray
Call GetUnsorted "PROTSHELL"
Call WriteFoundArray
Call GetUnsorted "LIBPATH"
Call WriteFoundArray
Call GetUnsorted "PRIORITY_DISK_IO"
Call WriteFoundArray
Call GetUnsorted "IOPL"
Call WriteFoundArray
Call GetUnsorted "DISKCACHE"
Call WriteFoundArray
Call GetUnsorted "MAXWAIT"
Call WriteFoundArray
Call GetUnsorted "MEMMAN"
Call WriteFoundArray
Call GetUnsorted "SWAPPATH"
Call WriteFoundArray
Call GetUnsorted "THREADS"
Call WriteFoundArray
Call GetUnsorted "PRINTMONBUFSIZE"
Call WriteFoundArray
Call GetUnsorted "PROTECTONLY"
Call WriteFoundArray
Call GetUnsorted "DEVINFO"
Call WriteFoundArray
rc=LineOut(TempCfg,"")
/* RUN und CALL anweisungen einsortieren */
Call AddRemark "Run And Call"
Call GetUnsortedRunAndCall
Call WriteFoundArray
rc=LineOut(TempCfg,"")
/* Rest unter unbekannt einsortieren */
Call AddRemark "Unknown"
Call WriteUnmatched
/* Datei schließen */
OFile=Stream(TempCfg,"C","CLOSE")
Exit
SortFoundArray:
Do i=1 To Found.0
L1=Found.i
If Left(L1,4)="REM " Then
Do
L1=Right(L1,Length(L1)-4)
End
Do j=i To Found.0
L2=Found.j
If Left(L2,4)="REM " Then
Do
L2=Right(L2,Length(L2)-4)
End
If L1>L2 Then
Do
T=Found.i
Found.i=Found.j
Found.j=T
L1=Found.i
If Left(L1,4)="REM " Then
Do
L1=Right(L1,Length(L1)-4)
End
End
End
End
Return
WriteFoundArray:
Do i=1 To Found.0
rc=LineOut(TempCfg,Found.i)
End
Return
GetUnsorted:
Sea1=Arg(1)
Sea2="REM "Arg(1)
Found.0=0
j=0
Do i=1 To CfgLine.0
Line=CfgLine.i
If (Translate(Left(Line,Length(Sea1)))=Translate(Sea1)) | (Translate(Left(Line,Length(Sea2)))=Translate(Sea2)) Then
Do
j=j+1
Found.j=Line
CfgLine.i=""
End
End
Found.0=j
Return
GetUnsortedRunAndCall:
Sea1="RUN"
Sea2="REM RUN"
Sea3="CALL"
Sea4="REM CALL"
Found.0=0
j=0
Do i=1 To CfgLine.0
Line=CfgLine.i
If (Left(Line,Length(Sea1))=Sea1) | (Left(Line,Length(Sea2))=Sea2) | (Left(Line,Length(Sea3))=Sea3) | (Left(Line,Length(Sea4))=Sea4) Then
Do
j=j+1
Found.j=Line
CfgLine.i=""
End
End
Found.0=j
Return
WriteUnmatched:
Do i=1 To CfgLine.0-1
If CfgLine.i="" Then
Nop
Else
rc=LineOut(TempCfg,CfgLine.i)
End
Return
AddRemark:
Call AddRemarkLine
rc=LineOut(TempCfg,"REM : "Arg(1)":")
Call AddRemarkLine
Return
AddRemarkLine:
rc=LineOut(TempCfg,"REM ***************************************************************************")
Return