120 lines
This file provides basic configuration information for the ULTRA 34F VL-BUS
SCSI controller. For a more detailed instructions, please refer to the ULTRA
34F User Manual.
1. Jumper Settings
(note : * denotes default settings)
JP2 : Factory Use
JP3 : Jumper Block 1
1-2 : Motor Spin Up Sequencing
*OUT Automatically drive spin up
IN Motor spin up from SCSI ID 0 to ID 7
3-4 : Synchronous Negotiation
*OUT ULTRA 34F initiated negotiation
IN Target initiated negotiation
5-6 7-8 : Interrupt Channel
OUT OUT IRQ 15
*OUT IN IRQ 14
IN OUT IRQ 11
IN IN IRQ 10
9-10 : SCSI Parity Control
*OUT Parity enabled
IN Parity disabled
11-12 13-14 15-16 : BIOS Address
OUT OUT OUT Disable
OUT OUT IN C4000 - C7FFF
*OUT IN OUT C8000 - CBFFF
OUT IN IN CC000 - CFFFF
IN OUT OUT D0000 - D3FFF
IN OUT IN D4000 - D7FFF
IN IN OUT D8000 - DBFFF
IN IN IN DC000 - DFFFF
JP4 : Jumper Block 2
1-2 3-4 : I/O Address
*OUT OUT 330H
OUT IN 340H
IN OUT 230H
IN IN 130H
5-6 : BIOS Support for More Than 2 Hard Disk Drives
*OUT Maximum 2 hard disk drives per system
IN Maximum 7 hard disk drives per controller
7-8 9-10 : Head Mapping Mode
OUT OUT 16 head 63 sector mapping
*OUT IN 64 head 32 sector mapping
IN OUT 64 head 63 sector mapping
IN IN 64 head 32 sector mapping
11-12 13-14 15-16 : Controller SCSI ID
OUT OUT OUT Reserved
OUT OUT IN 1
OUT IN OUT 2
OUT IN IN 3
IN OUT OUT 4
IN OUT IN 5
IN IN OUT 6
*IN IN IN 7
JP10 : Factory Use
2. Connectors
J1 : 50 pin internal SCSI connector
J2 : 50 pin high density external SCSI connector
JP5 : 4 pin controller activity LED connector
3. ULTRA BIOS Utility
To invoke the on-board BIOS utility, after a full system bootup to DOS
operating system, use the DOS "DEBUG" program to access the BIOS utility:
a. Load the DEBUG program by typing
DEBUG after the DOS prompt ( ">" sign )
b. Once in the DEBUG program, following the prompt ( "-" sign ), type
g=c800:5 or
whatever BIOS address the board is jumpered to.
The ULTRA BIOS utility displays SCSI ID, type, manufacturer, model number,
and mapping mode for each SCSI device attached to the ULTRA 34F; it also
provides functions for exercising SCSI devices.
Verify : Non-destructive media verfication for hard disks, removable hard
disks and magneto optical devices.
Scan : Same function as verify except it will issue "reassign bad
block" to the drive when defective sectors are found.
Format : Low level format of the SCSI device.
CFormat: Low level format of the SCSI device with the certification
option (CLIST) which re-sequences the good blocks.