  1. ISDN Primary LAN Distance Server Enabler Install Steps
  2. ------------------------------------------------------
  3.  
  4. <Primary Line Requirements>
  5.  
  6. 23B+D
  7. Data only including restricted Digital 56Kbps
  8. Separate D channel for each ISDN Primary Line
  9. Base Q.931 Call Control support only
  10. Compatible with AT&T 5ESS. AT&T 4ESS and DMS100 call control support.
  11.  
  12. Once you have a Primary line.
  13. The PRITEST in our install diskette can run under plain OS/2
  14. with our driver to test out if your PRIMARY line is OK.
  15.  
  16. <Software Installation>
  17.  
  18. Please use either process A or process B based on your needs.
  19. A wrap connector on the Primary adapter without a real PRIMARY line
  20. can also be used to complete installation.
  21.  
  22. <It is assumed you have LAN Distance 1.1 and Lan Distance 1.1 CSD.>
  23.  
  24. <A.Installation as a plain Connection Server>
  25.  
  26. It is recommended that the hard disk for install be formatted
  27. unless, the person installing the product is knowledgeable about
  28. the re-install and remove processes associated with currently
  29. installed applications.
  30.  
  31. 1) It is assumed that OS/2 Ver 2.1 or higher is installed
  32. and available on the PS/2 Model 95 server.
  33.  
  34. 2) Install the LAN Distance version 1.1 software
  35.      Insert the Server Diskette 1 into drive a: and type from the current
  36.      drive a:install.
  37.      You will be asked for the LAPS diskette (diskette 3) and then
  38.      diskettes Server 1 and Server 2.
  39.  
  40.    Install Lan Distance 1.1 CSD as required
  41.  
  42. Shutdown..restart
  43.  
  44.   LAN Distance configuration
  45.  
  46.     Start LAN Distance
  47.      click on Selected..Open As..settings.
  48.  
  49.     The following is a working set-up for a connection server
  50.  
  51.     The following steps may be carried out with directions provided in
  52.     the LAN Distance Advanced Guide V1.1
  53.  
  54.     Workstation..Define Name
  55.  
  56.     Ports..N/A
  57.  
  58.     Modems..N/A
  59.  
  60.     Bridge..Configure Filtering..Values
  61.             Bridge no 1, maximum size 2052
  62.             LAN segment..525 (Dependent on your system)
  63.             hops..8(Dependent on your system)
  64.             Accept frames from specified source addresses only
  65.             LAN_0001...provide addresses if address based filtering done
  66.             Wan no 2 , hops 8
  67.             maximum address 3500
  68.             LAN Type IEEE 802.5
  69.             Let it Generate a LAN address
  70.  
  71.     Answer..start ISDN all calls
  72.             click..change
  73.             ..Select-Enable answer mode on Startup
  74.  
  75.     Phone Book....ISDN
  76.     Timers
  77.        60000,10000,10000
  78.  
  79. shutdown..restart
  80.  
  81. 3) Install ISDN Primary Support
  82.      Insert the Primary Server Enable diskette in drive a:
  83.      Go to an OS/2 full screen
  84.      type a:install.
  85.  
  86.      Manually modify config.sys as per install document
  87.      Manually modify WCLNET.INI as per install document
  88.      Manually modify WCLLOCAL.INI as below
  89.  
  90.       {CXDDEFS}
  91.  
  92.          CXD = WCLDIAL.CXD
  93.          ISDNCHANNELS = 23   <--- add this statement
  94.  
  95. shutdown..restart
  96.  
  97. Activate LAN Distance..It will take a few minutes
  98.  
  99.      View ISDNPCML.CUR in the WAL subdirectory.
  100.      The last line should indicate SAPI/TEI 0/0 Established..card #n
  101.  
  102. <B.Installation with CM/2 and 3270 emulation resident at server>
  103.  
  104. It is recommended that the hard disk for install be formatted
  105. unless, the person installing the product is knowledgeable about
  106. the re-install and remove processes associated with currently
  107. installed applications.
  108.  
  109. 1) It is assumed that OS/2 Ver 2.1 or higher is installed
  110. and available on the PS/2 Model 95 server.
  111.  
  112. 2) If you already have Communication Manager CM/2 ver 1.1 installed
  113. proceed to step 3.
  114.  
  115. Install CM/2...Ignore LAPS install requirement,
  116.     Place Diskette 1 of CM/2 in drive and invoke the following command
  117.     Go to an OS/2 full screen
  118.           a:cmsetup
  119.     Proceed with Set-up and Configuration,
  120.     Configure for Token Ring, 3270 emulation
  121.  
  122. shutdown..restart
  123.  
  124. 3)Install LAPS.... Use diskette 3 provided with
  125.   your Lan Distance software product.
  126.     Place LAPS Diskette in drive a: and invoke the following command
  127.     Go to an OS/2 full screen
  128.           a:laps
  129.  
  130.     Configure LAPS
  131.       Select the adapter as
  132.          IBM Token Ring Adapter( or appropriate LAN adapter)
  133.  
  134.       Select the following protocols
  135.  
  136.         0- NETBIOS
  137.         0- IEEE802.2 (or appropriate Protocol)
  138.  
  139. shutdown..restart
  140.  
  141.     Start Communications manager
  142.     Try a VM session and it should work at this point.
  143.     If not, make sure you have the correct version of software for
  144.     OS/2 and CM/2.  Otherwise contact our software support
  145.     as mentioned in the install documentation.
  146.  
  147. 4) Install the LAN Distance version 1.1 software
  148.      Insert the Server Diskette 1 into drive a: and type from the current
  149.      drive a:install.
  150.      You will be asked for the LAPS diskette (diskette 3) and then
  151.      diskettes Server 1 and Server 2.
  152.  
  153.    Install Lan Distance 1.1 CSD as required
  154.  
  155. Shutdown..restart
  156.     Start LAN Distance
  157.      click on Selected..Open As..settings.
  158.  
  159.     The following is a working set-up for a connection server
  160.  
  161.     The following steps may be carried out with directions provided in
  162.     the LAN Distance Advanced Guide V1.1
  163.  
  164.     Workstation..Define Name
  165.  
  166.     Ports..N/A
  167.  
  168.     Modems..N/A
  169.  
  170.     Bridge..Configure Filtering..Values
  171.             Bridge no 1, maximum size 2052
  172.             LAN segment..525 (Dependent on your system)
  173.             hops..8(Dependent on your system)
  174.             Accept frames from specified source addresses only
  175.             LAN_0001...provide addresses if address based filtering done
  176.             Wan no 2 , hops 8
  177.             maximum address 3500
  178.             LAN Type IEEE 802.5
  179.             Let it Generate a LAN address
  180.  
  181.     Answer..start ISDN all calls
  182.             click..change
  183.             ..Select-Enable answer mode on Startup
  184.  
  185.     Phone Book....ISDN
  186.     Timers
  187.        60000,10000,10000
  188.  
  189. shutdown..restart
  190.  
  191. 5) Install ISDN Primary Support
  192.      Insert the Primary Server Enable diskette in drive a:
  193.      Go to an OS/2 full screen
  194.      type a:install.
  195.  
  196.      Manually modify config.sys as per install document
  197.      Manually modify WCLNET.INI as per install document
  198.      Manually modify WCLLOCAL.INI as below
  199.  
  200.       {CXDDEFS}
  201.  
  202.          CXD = WCLDIAL.CXD
  203.          ISDNCHANNELS = 23   <--- add this statement
  204.  
  205. shutdown..restart
  206.  
  207. Activate LAN Distance..It will take a few minutes
  208.  
  209.      View ISDNPCML.CUR in the WAL subdirectory.