; XMHZ-1.ASM - XMODEMxx PATCH FILE FOR HEATH/ZENITH Z100 11/17/83
;
; This file adapts XMODEMxx to the HEATH/ZENITH Z100 computers with ex-
; ternal modem. To use, first edit any options desired into XMODEMxx.ASM,
; then assemble (can use ASM.COM) and load to get XMODEMxx.COM. Then
; edit this file as needed (check the CONOUT routine if you want to loc-
; ally see file transfer time and the record count while programs are
; being sent). Then assemble (can use ASM.COM) and merge via DDT or SID:
;
; B>DDT XMODEMxx.COM
; DDT VERS 2.2
; NEXT PC
; 1180 0100
; -IXMHZ-1.HEX (note the 'I' command)
; -R ('R' loads in the .HEX file)
; NEXT PC
; 1180 0000
; -G0 (return to CP/M)
; B>SAVE 16 XMODEMxx.COM (now have a modified .COM file)
;
; NOTE: Save 21 (rather than 16) if LOGCAL is YES
;
;=======================================================================
;
; 11/17/83 - Renamed to XMHZ-1.ASM - Irv Hoff
; 10/22/83 - Updated to XMODEM77 - Irv Hoff
; 09/27/83 - Modified for Zenith Z100 - Paul Matlin
;
; 03/07/83 Added instructions on how to adapt this file to XMODEM70.COM.
; Standardized the format. Added automatic MSPEED from "BYE"
; program. Added CONOUT information. Adapted from XM70PMMI.
; - Irv Hoff
;
;=======================================================================
;
YES: EQU 0FFH
NO: EQU 0
;
;=======================================================================
;
; Values shown are for the 2661-2 serial I/O
;
MODDATP: EQU 0ECH ;data in port
MODDATO: EQU MODDATP ;data out port
MODCTLP: EQU MODDATP+1 ;line status register
MODCTL2: EQU MODDATP+1 ;modem status register
MODSNDB: EQU 01H ;bit to test for send
MODSNDR: EQU 01H ;value when ready
MODRCVB: EQU 02 ;bit to tet for receive
MODRCVR: EQU 02 ;value when ready
MODDCDA: EQU 40H ;value when active
MODDCDB: EQU 40H ;carrier detect bit
MODPARE: EQU 08H ;value for parity error
MODOVRE: EQU 10H ;value for overrun error
MODFRME: EQU 20H ;value for framing error
;
LSPEED: EQU YES ;yes if using 'BYE' with speed selection
;no if using 'SPEED' manual selection
MSPEED: EQU 3CH ;location of baud rate factor (set by
;'BYE') set location in 'BYE' to agree.
;3dh and 3eh often used by newer ver-
;sions of 'ZCPR'.
XSPEED: EQU 1 ;speed for file time transfer without
;auto-set. use one of the following:
;0=110 1=300 2=450 3=600 4=710 5=1200
BASE: EQU 100H ;start of cp/m normal program area
;
;-------------------------------------------------------------------
;
; Jump table: The jump table must be in exactly the same sequence as the
; one in XMODEM. Note the ORG of 103H - This jump table has no jump to
; 'BEGIN'.
;
ORG BASE+3 ;start after 'JMP BEGIN'
;
;
; NOTE: For the Zenith Z100 the CONOUT address is 0F9FFH
;
CONOUT: JMP 0F9FFH ;must be 00000h if not used, see below
PMINIT: JMP MINIT ;initialization routine (if needed)
PUNINIT: JMP UNINIT ;undo whatever 'MINIT' did (or return)
PSENDR: JMP SENDR ;send character (via pop psw)
PCAROK: JMP CAROK ;test for carrier
PMDIN: JMP MDIN ;receive data byte
PGETCHR: JMP GETCHR ;get character from modem
PRCVRDY: JMP RCVRDY ;check receive ready
PSNDRDY: JMP SNDRDY ;check send ready
PSPEED: JMP SPEED ;get speed value for file transfer time
PEXTRA1: JMP EXTRA1 ;extra for custom routine
PEXTRA2: JMP EXTRA2 ;extra for custom routine
PEXTRA3: JMP EXTRA3 ;extra for custom routine
;
;=======================================================================
;
; -- To Display the Record Count on the CRT During Program Transfers --
;
; This one addition requires some work on the part of the user.
; When "BYE" is added, CP/M is normally moved lower to accomodate the
; new program above CP/M. Whenever BYE is called to enable the RCPM
; capability, it steals some of the addresses contained in the BIOS jump
; vector table. In order to display on the CRT during program transfers
; you need to get into the BIOS console output routine directly, else
; what is being displayed also tries to go out the modem. This is a big
; NO-NO at that time. (This cannot be done automatically by XMODEM,
; since BYE has already taken the address we need to find, by the time
; XMODEM is automatically activated by the remote station.)
;
; So with the disk containing BYE, but prior to activating BYE, do
; this:
; 1) Cold reboot to move CP/M (and BIOS) to the new area
; needed when BYE is activated on the same disk.
; 2) Use DDT and dump the area from 0000H to 0002H. This
; gives the warm reboot address in BIOS.
; 3) Add 9 Bytes to that address to get your console out-
; put jump vector.
; 4) Pick off the address contained in the jump vector and
; install that in "CONOUT", below. Example of one
; system in use:
;
; FIRST, COLD REBOOT WITH DISK CONTAINING "BYE"
;
; 0000 C3 03 E0 (location of warm reboot on disk with BYE
;
; PRIOR TO ACTIVATING BYE BUT ON SAME DISK
;
; E003 C3 E9 E0 (BIOS warm reboot jump vector on this disk)
; E006 C3 00 E9 (BIOS get console status routine)
; E009 C3 B7 E1 (BIOS console input routine)
; E00C C3 D4 E1 (BIOS console output routine)
;
; The address we need is thus E1D4. Put that below, in
; our example it would be: CONOUT JMP 0E1D4H
;
;
; CONOUT: JMP 00000H ;If you wish to show the record count
; ;during program transfer, fill in this
; ;address at 'CONOUT' above.
;
; - Irv Hoff
;
;=======================================================================
;
; ---> CAROK - check for presence of carrier. RET with Z = carrier on
;
CAROK: IN MODCTL2 ;read modem status
ANI MODDCDB ;get carrier detect bit
CPI MODDCDA ;test bit
RET
;
;=======================================================================
;
EXTRA1: RET ;for later use
EXTRA2: RET ;for later use
EXTRA3: RET ;for later use
;
;=======================================================================
;
; ---> GETCHR - get a character, same as MDIN
; ---> MDIN - - get a character, same as GETCHR
;
GETCHR:
MDIN: IN MODDATP ;get character from data in port
RET
;
;=======================================================================
;
MINIT: RET ;no initialization required
;
;=======================================================================
;
; ---> RCVRDY - check receive ready. RET with Z = character available.
; Return with error code in A-reg.
;
RCVRDY: IN MODCTLP ;get modem status
PUSH B ;save scratch register
PUSH PSW ;check error status
ANI MODFRME+MODOVRE+MODPARE
MOV B,A ;save it for a moment
POP PSW
ANI MODRCVB ;isolate ready bit
CPI MODRCVR ;test it
MOV A,B ;get the error code char. back
POP B
RET
;
;=======================================================================
;
; ---> SENDR - send character
;
SENDR: POP PSW ;get the character back
OUT MODDATO ;send it to the modem output
RET
;
;=======================================================================
;
; ---> SNDRDY - check if ready to send.
;
SNDRDY: IN MODCTLP ;get status byte
ANI MODSNDB ;isolate ready bit
CPI MODSNDR ;ready to send?
RET
;
;=======================================================================
;
; ---> SPEED - sets the time shown for program transfer.
;
SPEED: IF LSPEED
LDA MSPEED ;get index for baud rate from 'BYE'
ENDIF
;
IF NOT LSPEED
MVI A,XSPEED ;get index for baud rate from 'XSPEED'
ENDIF
;
RET
;
;=======================================================================
;