home
***
CD-ROM
|
disk
|
FTP
|
other
***
search
/
ftp.barnyard.co.uk
/
2015.02.ftp.barnyard.co.uk.tar
/
ftp.barnyard.co.uk
/
cpm
/
walnut-creek-CDROM
/
CPM
/
MODEMS
/
MODEM7
/
M7R2-2.AQM
/
M7R2-2.ASM
Wrap
Assembly Source File
|
2000-06-30
|
11KB
|
347 lines
; M7R2-2.ASM -- TRS-80 Model II overlay file for MDM7xx. 05/16/84
;
; You will want to look this file over carefully. There are a number of
; options that you can use to configure the program to suit your taste.
; This file adapts the TRS-80 Model II (and probably Models 12 and 16)
; computers to MDM7xx. Requires Pickles & Trout CP/M.
;
; Much of the information contained here is not in the MDM7xx.ASM file.
;
; Edit this file for your preferences then follow the "TO USE:" example
; shown below.
;
; Use the "SET" command to change the baudrate when desired. It starts
; out at 300 baud when the program is first called up.
;
; MAKE SURE TO USE PICKLES & TROUT'S "SETUP.COM" TO SET INITIAL BAUD RATE
; TO 300 BAUD TO MATCH SETTING BELOW. (J.K.) (No longer needed - D.B.051684)
;
; TO USE: First edit this file filling in answers for your own
; equipment. Then assemble with ASM.COM or equivalent
; assembler. Then use DDT to overlay the the results
; of this program to the original .COM file:
;
; A>DDT MDM7xx.COM
; DDT VERS 2.2
; NEXT PC
; 4A00 0100
; -IM7Rx-x.HEX (note the "I" command)
; -R ("R" loads in the .HEX file)
; NEXT PC
; 0301 0000
; -G0 (return to CP/M)
; A>SAVE 73 MDM7xx.COM (now have a modified .COM file)
;
; = = = = = = = = = = = = = = = = = =
;
; 05/16/84 - Updated to change baud rates using
; Pickles & Trout System Call. - Dan Blana
; 11/11/83 - Renamed to M7R2-1.ASM, no changes - Irv Hoff
; 09/18/83 - Modified M712XE.ASM for
; TRS-80 Model II and Pickles
; & Trout CP/M (should also
; work on Mods 12 and 16) - Joseph Katz
;
; = = = = = = = = = = = = = = = = = =
;
BELL: EQU 07H ;bell
CR: EQU 0DH ;carriage return
ESC: EQU 1BH ;escape
LF: EQU 0AH ;linefeed
;
YES: EQU 0FFH
NO: EQU 0
;
;
PORT: EQU 0F4H ;TRS-80 II serial output port A
MODCTL1: EQU PORT+2 ;Modem control port
MODDATP: EQU PORT ;Modem data port
MODCTL2: EQU PORT+2 ;Modem status port
MODRCVB: EQU 01H ;Bit to test for receive
MODRCVR: EQU 01H ;Value when receive ready
MODSNDB: EQU 04H ;Bit to test for send
MODSNDR: EQU 04H ;Value when send ready
;
;
ORG 100H
;
;
; Change the clock speed to suit your system
;
DS 3 ;(for "JMP START" instruction)
;
PMMIMODEM: DB NO ;yes=PMMI S-100 Modem 103H
SMARTMODEM: DB YES ;yes=HAYES Smartmodem, no=non-PMMI 104H
TOUCHPULSE: DB 'T' ;T=touch, P=pulse (Smartmodem-only) 105H
CLOCK: DB 40 ;clock speed in MHz x10, 25.5 MHz max. 106H
;20=2 MHh, 37=3.68 MHz, 40=4 MHz, etc.
MSPEED: DB 1 ;0=110 1=300 2=450 3=600 4=710 5=1200 107H
;6=2400 7=4800 8=9600 9=19200 default
BYTDLY: DB 5 ;0=0 delay 1=10ms 5=50 ms - 9=90 ms 108H
;default time to send character in ter-
;minal mode file transfer for slow BBS.
CRDLY: DB 5 ;0=0 delay 1=100 ms 5=500 ms - 9=900 ms 109H
;default time for extra wait after CRLF
;in terminal mode file transfer
NOOFCOL: DB 5 ;number of DIR columns shown 10AH
SETUPTST: DB YES ;yes=user-added Setup routine 10BH
SCRNTEST: DB YES ;Cursor control routine 10CH
ACKNAK: DB YES ;yes=resend a record after any non-ACK 10DH
;no=resend a record after a valid NAK
BAKUPBYTE: DB NO ;yes=change any file same name to .BAK 10EH
CRCDFLT: DB YES ;yes=default to CRC checking 10FH
TOGGLECRC: DB YES ;yes=allow toggling of CRC to Checksum 110H
CONVBKSP: DB NO ;yes=convert backspace to rub 111H
TOGGLEBK: DB YES ;yes=allow toggling of bksp to rub 112H
ADDLF: DB NO ;no=no LF after CR to send file in 113H
;terminal mode (added by remote echo)
TOGGLELF: DB YES ;yes=allow toggling of LF after CR 114H
TRANLOGON: DB NO ;yes=allow transmission of logon 115H
;write logon sequence at location LOGON
SAVCCP: DB YES ;yes=do not overwrite CCP 116H
LOCONEXTCHR: DB NO ;yes=local command if EXTCHR precedes 117H
;no=external command if EXTCHR precedes
TOGGLELOC: DB YES ;yes=allow toggling of LOCONEXTCHR 118H
LSTTST: DB YES ;yes=printer available on printer port 119H
XOFFTST: DB NO ;yes=check for XOFF from remote while 11AH
;sending a file in terminal mode
XONWAIT: DB NO ;yes=wait for XON after CR while 11BH
;sending a file in terminal mode
TOGXOFF: DB YES ;yes=allow toggling of XOFF checking 11CH
IGNORCTL: DB YES ;yes=CTL-chars above ^M not displayed 11DH
EXTRA1: DB 0 ;for future expansion 11EH
EXTRA2: DB 0 ;for future expansion 11FH
BRKCHR: DB '@'-40H ;^@ = Send a 300 ms. break tone 120H
20H
NOCONNCT: DB 'N'-40H ;^N = Disconnect from the phone line 121H
LOGCHR: DB 'L'-40H ;^L = Send logon 122H
LSTCHR: DB 'P'-40H ;^P = Toggle printer 123H
UNSAVE: DB 'R'-40H ;^R = Close input text buffer 124H
TRANCHR: DB 'T'-40H ;^T = Transmit file to remote 125H
SAVECHR: DB 'Y'-40H ;^Y = Open input text buffer 126H
EXTCHR: DB '^'-40H ;^^ = Send next character 127H
;
;
DS 2 ; 128H
IN$MODCTL1: MVI A,10H ;channel 0, reset interrupts 12AH
OUT MODCTL1
IN MODCTL1 ;get the status bits
RET
DS 3
;
OUT$MODDATP: OUT MODDATP ! RET ;out modem data port 134H
DS 7
IN$MODDATP: IN MODDATP ! RET ;in modem data port 13EH
DS 7
ANI$MODRCVB: ANI MODRCVB ! RET ;bit to test for receive ready 148H
CPI$MODRCVR: CPI MODRCVR ! RET ;value of receive bit when rdy 14BH
ANI$MODSNDB: ANI MODSNDB ! RET ;bit to test for send ready 14EH
CPI$MODSNDR: CPI MODSNDR ! RET ;value of send bit when ready 151H
DS 6 ; 154H
OUT$MODCTL1: OUT MODCTL1 ! RET ;out modem control port 15AH
OUT$MODCTL2: OUT MODCTL2 ! RET ;out modem status port 15DH
;
;
LOGONPTR: DW LOGON ;for user message. 160H
DS 6 ; 162H
JMP$GOODBYE: JMP GOODBYE ; 168H
JMP$INITMOD: JMP INITMOD ;go to user written routine 16BH
RET ! NOP ! NOP ;(by-passes PMMI routine) 16EH
RET ! NOP ! NOP ;(by-passes PMMI routine) 171H
RET ! NOP ! NOP ;(by-passes PMMI routine) 174H
JMP$SETUPR: JMP SETUPR ; 177H
JMP$SPCLMENU: JMP SPCLMENU ; 17AH
JMP$SYSVER: JMP SYSVER ; 17DH
JMP$BREAK: JMP SENDBRK ; 180H
;
;
; Do not change the following six lines.
;
JMP$ILPRT: DS 3 ; 183H
JMP$INBUF DS 3 ; 186H
JMP$INLNCOMP: DS 3 ; 189H
JMP$INMODEM DS 3 ; 18CH
JMP$NXTSCRN: DS 3 ; 18FH
JMP$TIMER: DS 3 ; 192H
;
;
; Clear sequences -- CLREOS is clear to end of screen, CLRSCRN is clear
; entire screen. Last entry must be 0. Any other 0's act as NOP's.
;
CLREOS: CALL JMP$ILPRT ; 195H
DB 02H,0,0,0,0 ; 198H
RET ; 19DH
;
CLRSCRN: CALL JMP$ILPRT ; 19EH
DB 0CH,0,0,0,0 ; 1A1H
RET ; 1A6H
;
;
SYSVER: CALL JMP$ILPRT ; 1A7H
DB 'TRS-80 VERSION (FOR SERIAL PORT A)',CR,LF
DB CR,LF,0
RET
;.....
;
;
;-----------------------------------------------------------------------
;
; NOTE: You can change the SYSVER message to be longer or shorter. The
; end of your last routine should terminate by 0400H (601 bytes
; available after start of SYSVER) if using the Hayes Smartmodem
; or by address 0C00H (2659 bytes) otherwise.
;
;-----------------------------------------------------------------------
;
; You can put in a message at this location which can be called up with
; CTL-O if TRANLOGON has been set TRUE. You can put in several lines if
; desired. End with a 0.
;
;
LOGON: DB 'This is a TRS-80 computer',CR,LF,0
;.....
;
;
; This routine allows a 300 ms. break tone to be sent to reset some
; time-shar computers.
;
SENDBRK: MVI A,5
OUT MODCTL1
MVI A,0F8H ;SEND A BREAK TONE
JMP GOODBYE1
;.....
;
;
; This routine sends a 300 ms. break tone and sets DTR low for the same
; length of time to disconnect some modems such as the Bell 212A, etc.
;
GOODBYE: MVI A,5
OUT MODCTL1 ;SEND TO THE STATUS PORT
MVI A,68H ;TURN OFF DTR
;
GOODBYE1: OUT MODCTL1
MVI B,3 ;WAIT FOR 300 MS.
CALL JMP$TIMER
MVI A,5
OUT MODCTL1
MVI A,0E8H ;RESTORE TO NORMAL, 8 BITS, DTR ON, ETC.
OUT MODCTL1
RET
;.....
;
;
; TRS-80 II initialization -- sets CTC timer 00H for send and receive
; baudrate.
;
INITMOD:
MVI A,0 ;SELECT REGISTER
OUT MODCTL1
MVI A,18H ;THROW OUT OF MODE
OUT MODCTL1
MVI A,04H ;SELECT REGISTER
OUT MODCTL1
MVI A,44H ;SET ASCII PARAMETERS
OUT MODCTL1
MVI A,03H ;SELECT REG.
OUT MODCTL1
MVI A,0C1H ;ENABLE RECEIVE
OUT MODCTL1
MVI A,05H ;SELECT REG.
OUT MODCTL1
MVI A,0EAH ;ENABLE SEND, 'DTR', 'RTS'
OUT MODCTL1
JMP OK300 ;DEFAULT SET 300 BAUD RATE P&T FUNC
;
;.....
;
;
; Setup routine to allow changing modem speed with the SET command.
;
SETUPR: LXI D,BAUDBUF ;POINT TO NEW INPUT BUFFER
CALL JMP$ILPRT
DB 'Input Baud Rate (300 OR 1200): ',0
CALL JMP$INBUF
LXI D,BAUDBUF+2
CALL JMP$INLNCOMP ;COMPARE BAUDBUF+2 WITH CHARACTERS BELOW
DB '300',0
JNC OK300 ;GO IF GOT MATCH
CALL JMP$INLNCOMP ;SMODEM DOESN'T SUPPORT
DB '600',0
JNC OK600
CALL JMP$INLNCOMP
DB '1200',0
JNC OK1200
CALL JMP$INLNCOMP ;SMODEM DOESN'T SUPPORT 9600
DB '9600',0
JNC OK9600
CALL JMP$ILPRT ;ALL MATCHES FAILED, TELL OPERATOR
DB '++ Incorrect entry ++',CR,LF,BELL,0
JMP SETUPR ;TRY AGAIN
;
OK300: MVI A,1
LHLD BD300
JMP LOADBD
;
OK600: MVI A,3
LHLD BD600
JMP LOADBD
;
OK1200: MVI A,5
LHLD BD1200
JMP LOADBD
;
OK9600: MVI A,8
LHLD BD9600
;
LOADBD: STA INITMOD1+1 ;CHANGE TIME-TO-SEND TO MATCH BAUDRATE
MOV A,L ;GET BAUDRATE BYTE
STA INITMOD2+1 ;SEND TO 'CTC' TIMER FOR NEW BAUDRATE
;
INITMOD1: MVI A,1 ;DEFAULT TRANSFER TIME TO 300 BAUD
STA MSPEED
MVI A,47H ;DEFAULT TO 300 BAUD
OUT 00H ;SEND TO 'CTC' TIMER
;
INITMOD2: MVI A,03H ;INITIALIZE TO 300 BAUD
OUT 00H
;
; Setup Serial PORT 'A' using P&T Special System Function #0
;
SSFUNC0: PUSH B ;---- SAVE REGISTERS
PUSH D ;----
PUSH H ;----
PUSH PSW ;----
LXI B,0 ;FUNCTION #0 - SETUP SERIAL PORT
; DISABLE PARITY, ODD PARITY, PORT A
MVI D,0E6H ;RTS=HIGH,01 STOP BIT,8 BITS;DTR=HIGH
MOV E,H ;BAUD FROM BAUD RATE PARAMETERS TBL
MVI H,13H ;XOFF CHAR - 13H (19D)
MVI L,11H ;XON CHAR - 11H (17D)
CALL 0040H ;CALL P&T SPECIAL SYSTEM FUNCTION
POP PSW ;---- RESTORE SAVED REGISTERS
POP H ;----
POP D ;----
POP B ;----
RET
;
;
; TABLE OF BAUDRATE PARAMETERS
;
BD300: DW 0303H
BD600: DW 0406H
BD1200: DW 050DH
BD9600: DW 080EH
;
BAUDBUF: DB 10,0
DS 10
;
;-----------------------------------------------------------------------
;
; The following routine can be used as an auxiliary menu for notes of
; interest to a particular computer, etc. If using the Hayes Smartmodem
; this is unavailable without a special address change.
;
SPCLMENU: RET
;
;-------------------------------------------------