home
***
CD-ROM
|
disk
|
FTP
|
other
***
search
/
ftp.barnyard.co.uk
/
2015.02.ftp.barnyard.co.uk.tar
/
ftp.barnyard.co.uk
/
cpm
/
walnut-creek-CDROM
/
CPM
/
MODEMS
/
MODEM7
/
M7MH-2.AQM
/
M7MH-2.ASM
Wrap
Assembly Source File
|
2000-06-30
|
13KB
|
419 lines
;
; M7MH-2.ASM -- Morrow Decision MD-11 computer 08/09/84
; w/ SmartModem on Auxillary Port
; overlay file for MDM7xx.
;
;-------------------------------------------------------------------------
;
; 08/09/84 - Updated, more baud rates - George Reding
; 07/01/84 - First version of M7MH-1.ASM - George Reding
; Modified from M7GP-1.ASM by - Irv Hoff
;
;-------------------------------------------------------------------------
; Updated version based on additional information obtained from the Morrow
; Corp via Xerox (local service representative). This will allow operation
; at most any baudrate - not previously implemented. This version is for
; the Zilog SIO/9 chip (identical to the Zilog SIO except only channel A
; is operational). An Intel 8253 CTC chip is used to control baud rates.
;
; Thanks to those who helped me with first version, namely creators of the
; patch named B3SIO.ASM, plus advice from David Bowerman and Gordon Regar.
; - G.Reding 08/09/84
;-------------------------------------------------------------------------
;
; TO USE: First edit this file selecting your desired options,
; then assemble with MAC, ASM, or equivalent assembler.
; Morrow MD-11 users then use SID or DDT to overlay the
; results of this program to the original COM file.
;
;
; A>SAVE <-- type this first
;
; A>DDT MDM7xx.COM
; DDT VERS 2.2
; NEXT PC
; 4A00 0100
; -IM7MH-2.HEX (note the "I" command)
; -R ("R" loads in the .HEX file)
; NEXT PC
; 4A00 0000
; -G0 (return to CP/M)
;
; CP/M 3 SAVE - Version 3.0
; Enter file (type RETURN to exit): MDM7xx.COM <-- new filename
; Beginning hex address 0100 <-- from having used DDT or SID
; Ending hex address 4A00 <-- you enter both of these
;
; A> (now have a modified .COM file)
;
;-------------------------------------------------------------------------
;
; SIO & CTC Chip Equates
; """"""""""""""""""""""
; Port addresses:
;
BPORT: EQU 50H ;Aux Port divisor latch of 8253 CTC.
BPORT2: EQU 53H ;counter timer mode control.
BASEP: EQU 70H ;Zilog SIO/9. Identical to Zilog SIO,
;except only channel A is operational
; (MD-11 Aux Port uses channel A)
DATPORT: EQU BASEP ;data port
STPORT: EQU BASEP+1 ;status/control port
;
; STPORT commands (output to STPORT):
;
RESCHN: EQU 00011000B ;reset channel
RESSTA: EQU 00010000B ;reset external status
WRREG1: EQU 00000000B ;value to write to register 1
WRREG3: EQU 11000001B ;8 bits/char, rx on
WRREG4: EQU 01000100B ;16x, 1 stop, no parity
DTROFF: EQU 00000000B ;dtr and rts off
DTRON: EQU 11101010B ;drt on, rts on, tx on, 8 bit/char
ONINS: EQU 00110000B ;error reset
BRKON: EQU 11111010B ;dtr on, rts on, tx on, break on, 8 bit/char
BRKOFF: EQU 11101010B ;dtr on, rts on, tx on, break off, 8 bit/char
;
; STPORT status masks:
;
DAV: EQU 00000001B ;data available
TRDY: EQU 00000100B ;transmit buffer empty
DCD: EQU 00001000B ;data carrier detect
CTS: EQU 00100000B ;clear to send input status
;
;-------------------------------------------------------------------------
;
BELL: EQU 07H ;bell
CR: EQU 0DH ;carriage return
ESC: EQU 1BH ;escape
LF: EQU 0AH ;linefeed
;
YES: EQU 0FFH
NO: EQU 0
;
; Change the following information to match your equipment
;
MODCTL1: EQU STPORT ;MODEM CONTROL PORT
MODDATP: EQU DATPORT ;MODEM DATA IN PORT
MODDATO: EQU DATPORT ;MODEM DATA OUT PORT
MODDCDB: EQU DCD ;CARRIER DETECT BIT
MODDCDA: EQU 0 ;VALUE WHEN ACTIVE
MODCTL2: EQU STPORT ;2ND MODEM CONTROL PORT
MODRCVB: EQU DAV ;BIT TO TEST FOR RECEIVE
MODRCVR: EQU DAV ;VALUE WHEN READY
MODSNDB: EQU TRDY ;BIT TO TEST FOR SEND
MODSNDR: EQU TRDY ;VALUE WHEN READY
;
;-------------------------------------------------------------------------
;
ORG 100H
;
; Change the clock speed to suit your system
;
DS 3 ;(for "JMP START" instruction)
;
PMMIMODEM: DB NO ;yes=PMMI S-100 Modem 103H
SMARTMODEM: DB YES ;yes=HAYES Smartmodem, no=non-PMMI 104H
TOUCHPULSE: DB 'T' ;T=touch, P=pulse (Smartmodem-only) 105H
CLOCK: DB 40 ;clock speed in MHz x10, 25.5 MHz max. 106H
;20=2 MHh, 37=3.68 MHz, 40=4 MHz, etc.
MSPEED: DB 1 ;0=110 1=300 2=450 3=600 4=710 5=1200 107H
;6=2400 7=4800 8=9600 9=19200 default
BYTDLY: DB 5 ;0=0 delay 1=10ms 5=50 ms - 9=90 ms 108H
;default time to send character in ter-
;minal mode file transfer for slow BBS.
CRDLY: DB 5 ;0=0 delay 1=100 ms 5=500 ms - 9=900 ms 109H
;default time for extra wait after CRLF
;in terminal mode file transfer
NOOFCOL: DB 5 ;number of DIR columns shown 10AH
SETUPTST: DB YES ;yes=user-added Setup routine 10BH
SCRNTEST: DB YES ;Cursor control routine 10CH
ACKNAK: DB YES ;yes=resend a record after any non-ACK 10DH
;no=resend a record after a valid-NAK
BAKUPBYTE: DB NO ;yes=change any file same name to .BAK 10EH
CRCDFLT: DB YES ;yes=default to CRC checking 10FH
TOGGLECRC: DB YES ;yes=allow toggling of CRC to Checksum 110H
CONVBKSP: DB NO ;yes=convert backspace to rub 111H
TOGGLEBK: DB YES ;yes=allow toggling of bksp to rub 112H
ADDLF: DB NO ;no=no LF after CR to send file in 113H
;terminal mode (added by remote echo)
TOGGLELF: DB YES ;yes=allow toggling of LF after CR 114H
TRANLOGON: DB YES ;yes=allow transmission of logon 115H
;write logon sequence at location LOGON
SAVCCP: DB YES ;yes=do not overwrite CCP 116H
LOCONEXTCHR: DB NO ;yes=local command if EXTCHR precedes 117H
;no=external command if EXTCHR precedes
TOGGLELOC: DB YES ;yes=allow toggling of LOCONEXTCHR 118H
LSTTST: DB YES ;yes=printer available on printer port 119H
XOFFTST: DB YES ;yes=checks for XOFF from remote while 11AH
;sending a file in terminal mode
XONWAIT: DB NO ;yes=wait for XON after CR while 11BH
;sending a file in terminal mode
TOGXOFF: DB YES ;yes=allow toggling of XOFF checking 11CH
IGNORCTL: DB YES ;yes=CTL-chars above ^M not displayed 11DH
EXTRA1: DB 0 ;for future expansion 11EH
EXTRA2: DB 0 ;for future expansion 11FH
BRKCHR: DB '@'-40H ;^@ = Send 300 ms. break tone 120H
NOCONNCT: DB 'N'-40H ;^N = Disconnect from the phone line 121H
LOGCHR: DB 'L'-40H ;^L = Send logon 122H
LSTCHR: DB 'P'-40H ;^P = Toggle printer 123H
UNSAVE: DB 'R'-40H ;^R = Close input text buffer 124H
TRANCHR: DB 'T'-40H ;^T = Transmit file to remote 125H
SAVECHR: DB 'Y'-40H ;^Y = Open input text buffer 126H
EXTCHR: DB '^'-40H ;^^ = Send next character 127H
DS 2 ; 128H
;
IN$MODCTL1: IN MODCTL1 ! RET ;in modem control port 12AH
DS 7
OUT$MODDATP: OUT MODDATP ! RET ;out modem data port 134H
DS 7
IN$MODDATP: IN MODDATP ! RET ;in modem data port 13EH
DS 7
ANI$MODRCVB: ANI MODRCVB ! RET ;bit to test for receive ready 148H
;
CPI$MODRCVR: CPI MODRCVR ! RET ;value of rcv. bit when ready 14BH
ANI$MODSNDB: ANI MODSNDB ! RET ;bit to test for send ready 14EH
CPI$MODSNDR: CPI MODSNDR ! RET ;value of send bit when ready 151H
DS 6 ; 156H
;
OUT$MODCTL1: OUT MODCTL1 ! RET ;out modem control port #2 15AH
OUT$MODCTL2: OUT MODCTL2 ! RET ;out modem control port #1 15DH
;
LOGONPTR: DW LOGON ;for user message. 160H
DS 6 ; 162H
JMP$GOODBYE: JMP GOODBYE ; 168H
JMP$INITMOD: JMP INITMOD ;go to user written routine 16BH
RET ! NOP ! NOP ;(by-passes PMMI routine) 16EH
RET ! NOP ! NOP ;(by-passes PMMI routine) 171H
RET ! NOP ! NOP ;(by-passes PMMI routine) 174H
JMP$SETUPR: JMP SETUPR ; 177H
JMP$SPCLMENU: JMP SPCLMENU ; 17AH
JMP$SYSVER: JMP SYSVER ; 17DH
JMP$BREAK: JMP SENDBRK ; 180H
;
; Do not change the following six lines.
;
JMP$ILPRT: DS 3 ; 183H
JMP$INBUF DS 3 ; 186H
JMP$INLNCOMP: DS 3 ; 189H
JMP$INMODEM DS 3 ; 18CH
JMP$NXTSCRN: DS 3 ; 18FH
JMP$TIMER DS 3 ; 192H
;
;
; Routine to clear to end of screen. If using CLREOS and CLRSCRN, set
; SCRNTEST to YES at 010AH (above).
;
CLREOS: CALL JMP$ILPRT ; 195H
DB ESC,59H,0,0,0 ; 198H
RET ; 19DH
;
;
CLRSCRN: CALL JMP$ILPRT ; 19EH
DB 1EH,ESC,59H,0,0 ; 1A1H
RET ; 1A6H
;
;
SYSVER: CALL JMP$ILPRT ; 1A7H
DB 'Version for Morrow Decision MD-11',CR,LF
DB 'with SmartModem on Auxillary Port',CR,LF
DB 0
RET
;
;-----------------------------------------------------------------------
; NOTE: You can change the SYSVER message to be longer or shorter. The
; END of your LAST routine should terminate by 0400H (601 bytes
; available after start of SYSVER) if using the Hayes Smartmodem
; or by address 0C00H (2659 bytes) otherwise.
;-----------------------------------------------------------------------
;
; Put in a message here which can be called up with CTL-O if TRANLOGON has
; been set TRUE. You can use several lines if desired. End with a 0.
;
LOGON: DB 'This is a Morrow Decision MD-11 computer'
DB CR,LF
DB 0,0,0,0,0,0
;
;
;*************************************************************************
; If any of your routines zap anything other than the Accumulator, then
; you must preserve all other registers.
;*************************************************************************
;
; This will send a break tone to reset some time-share computers.
;
SENDBRK: MVI A,5 ;setup to write reg 5
OUT STPORT
MVI A,BRKON ;dtr on, rts on, tx on, break on, 8 bit/char
OUT STPORT
MVI B,3 ;300ms of break
CALL JMP$TIMER
MVI A,5 ;setup to write reg 5
OUT STPORT
MVI A,BRKOFF ;dtr on, rts on, tx on, break off, 8 bit/char
OUT STPORT
RET
;
;
; This will turn off DTR, etc causing modem to hangup.
;
GOODBYE: MVI A,5 ;setup to write reg 5
OUT STPORT
MVI A,DTROFF ;clear dtr causing hangup
OUT STPORT
MVI B,3 ;for 300ms
CALL JMP$TIMER
MVI A,5 ;setup to write reg 5
OUT STPORT
MVI A,DTRON ;dtr on, rts on, tx on, 8 bit/char
OUT STPORT ;so we can use modem again
RET ;return
;
;
; Setup the modem port (MD-11 Aux Port).
;
INITMOD: MVI A,4 ;setup to write reg 4
OUT STPORT
MVI A,WRREG4 ;16x, 1 stop, no parity
OUT STPORT
;
MVI A,1 ;setup to write reg 1
OUT STPORT
MVI A,WRREG1 ;value to write to register 1
OUT STPORT
;
MVI A,3 ;setup to write reg 3
OUT STPORT
MVI A,WRREG3 ;initialize receive register
OUT STPORT
;
MVI A,5 ;setup to write reg 5
OUT STPORT
MVI A,DTRON ;dtr on, 8 bit/char, tx enable, rts
OUT STPORT ;so we can use modem
;
IN DATPORT ;clean out garbage
IN DATPORT ;make sure its clear
JMP SET300 ;setup default baud (300)
;and return
;
;
; The following set the baud rate for the modem. If you do not support a
; particular rate, then put the label in front of the SETINV routine. If
; the baud rate change was successful, make SURE the Zero flag is set.
;
SETUPR: LXI D,BAUDBUF ;point to new input buffer
CALL JMP$ILPRT
DB 'Select baud rate '
DB '(300, 450, 600, 710, 1200): ',0
CALL JMP$INBUF
LXI D,BAUDBUF+2
CALL JMP$INLNCOMP ;compare baudbuf+2 with below
DB '300',0
JNC SET300 ;if match, do it
CALL JMP$INLNCOMP ;else check..
DB '450',0
JNC SET450
CALL JMP$INLNCOMP ;..until we
DB '600',0
JNC SET600
CALL JMP$INLNCOMP ;..find a match
DB '710',0
JNC SET710
CALL JMP$INLNCOMP ;..and do it
DB '1200',0
JNC SET1200
CALL JMP$ILPRT ;else say no match
DB '++ Incorrect entry ++',CR,LF,BELL,0
JMP SETUPR ;try again
;
;
SET300: MVI A,1 ;value for MSPEED
STA MSPEED ;store it
;
MVI A,3EH ;Aux:= Mode 3 (Channel 0)
OUT BPORT2 ;counter timer mode control
LXI H,BD300 ;baud rate value
JMP SETBAUD ;go finish setting
;
;
SET450: MVI A,2
STA MSPEED
MVI A,3EH
OUT BPORT2
LXI H,BD450
JMP SETBAUD
;
;
SET600: MVI A,3
STA MSPEED
MVI A,3EH
OUT BPORT2
LXI H,BD600
JMP SETBAUD
;
;
SET710: MVI A,4
STA MSPEED
MVI A,3EH
OUT BPORT2
LXI H,BD710
JMP SETBAUD
;
;
SET1200: MVI A,5
STA MSPEED
MVI A,3EH
OUT BPORT2
LXI H,BD1200
;
;
SETBAUD: MOV A,L
OUT BPORT ;Aux Port divisor latch LOW
MOV A,H
OUT BPORT ;Aux Port divisor latch HIGH
XRA A ;say rate okay
RET ;return
;
;
; The returns a 255 because we were not able to set to the proper baud rate
; because either the serial port or the modem cant handle it.
;
SET110: DS 0 ;110 baud not supported
;
SETINV: ORI 0FFH ;make sure zero flag is not set
RET ;return
;
;
; The following divisors for BPORT (Aux Port divisor latch) for the Morrow
; MD-11 were obtained from Morrow Corp, except the 450 and 710 bps which I
; calculated based on the others (correct?). Bauds other than 300 and 1200
; I haven't tested - no means to do so. Labels correspond with baud rates.
; -G.Reding 08/09/84
BD110: EQU 08E0H
BD300: EQU 0341H
BD450: EQU 022DH
BD600: EQU 01A1H
BD710: EQU 0160H
BD1200: EQU 00D0H
BD2400: EQU 0068H
BD4800: EQU 0034H
BD9600: EQU 001AH
BD19200: EQU 000DH
;
;
BAUDBUF: DB 10,0
DS 10
;
;
; If using Hayes Smartmodem following is unavailable without a special
; change.
;
SPCLMENU: RET
;
;
; NOTE: MUST TERMINATE PRIOR TO 0400H (with Smartmodem)
; 0C00H (without Smartmodem)
;
END
;