home
***
CD-ROM
|
disk
|
FTP
|
other
***
search
/
ftp.barnyard.co.uk
/
2015.02.ftp.barnyard.co.uk.tar
/
ftp.barnyard.co.uk
/
cpm
/
walnut-creek-CDROM
/
CPM
/
MODEMS
/
MODEM7
/
M7H8-2-1.AQM
/
M7H8-2-1.ASM
Wrap
Assembly Source File
|
2000-06-30
|
12KB
|
347 lines
; M7H8-2-1.ASM -- Heath/Zenith H8/H89 overlay file for MDM7xx.COM
;
; You will want to look this file over carefully. There are a number of
; options that you can use to configure the program to suit your taste.
; This file places particular emphasis on using the Heath/Zenith equip-
; ment with 2651/2661 PCI serial I/O. Much of the information contained
; here is not in the main file. If not using the Heath H8, H89 with
; 2651, or 2661 PCI I/O, but with the 8250 serial I/O, then use M7H8-1.
; ASM overlay. If not using Heath/Zenith equipment, some of the rou-
; tines here will illustrate what you could do with your equipment.
;
;
; Use the "SET" command to change baudrate when desired.
;
; Edit this file for your preferences then follow the "TO USE:" example
; shown below.
;
;
; TO USE: First edit this file filling in answers for your own
; equipment. Then assemble with ASM.COM or equivalent
; assembler. Then use DDT to overlay the the results
; of this program to the original .COM file:
;
; A>DDT MDM7xx.COM
; DDT VERS 2.2
; NEXT PC
; 4A00 0100
; -IM7H8-2-1.HEX (note the "I" command)
; -R ("R" loads in the .HEX file)
; NEXT PC
; 4A00 0000
; -G0 (return to CP/M)
; A>SAVE 73 MDM7xx.COM (now have a modified .COM file)
;
; NOTE!: Be sure to check the NEXT address above with what you get
; when you load MDM7xx.COM with DDT. If the two addresses
; differ, you need to adjust the number of 'PAGES' to SAVE
; by the amount of the differance. If the address you get
; is larger, then add the differance to the number of pages
; to SAVE. If it is smaller, then subtract the differance.
;
; = = = = = = = = = = = = = = = = = =
;
; 13-MAY-86 - Revised to work with H8 / H89 2651/2661 PCI USART - WEA
; 06-APR-86 - Updated to work with H8 2651 I/O. Renamed M7H8-2.ASM - WEA
; 11/11/83 - Renamed to M7H8-1.ASM, no changes - Irv Hoff
; 07/27/83 - Renamed to work with MDM712 - Irv Hoff
; 07/01/83 - Revised to work with MDM711 - Irv Hoff
; 06/22/83 - Revised to work with MDM710 - Irv Hoff
; 05/27/83 - Revised to work with MDM709 - Irv Hoff
; 05/15/83 - Revised to work with MDM708 - Irv Hoff
; 04/17/83 - Revised to work with MDM707 - Irv Hoff
; 04/04/83 - Updated to work with MDM706 - Irv Hoff
; 02/27/83 - Updated to work with MDM705 - Irv Hoff
; 02/17/83 - Updated to work with MDM704 - Irv Hoff
; 02/07/83 - Updated to work with MDM703 - Irv Hoff
; 01/27/83 - Updated to work with MDM702 - Irv Hoff
; 01/10/83 - Updated to work with MDM701 - Irv Hoff
; 10/03/82 - First version of this file
;
; = = = = = = = = = = = = = = = = =
;
BELL: EQU 07H ;bell
CR: EQU 0DH ;carriage return
ESC: EQU 1BH ;escape
LF: EQU 0AH ;linefeed
;
YES: EQU 0FFH
NO: EQU 0
;
;
; Change the value at MODDATP if it does not match what you are using.
;
MODDATP: EQU 340Q ;data port for H8 2651 PCI
MODCTL1: EQU MODDATP+1 ;status port for H8 2651/2661 PCI
MODRCVB: EQU 2H ;bit to test for Receiver Ready
MODRCVR: EQU 2H ;Receive Holding Reg. Has DATA
MODSNDB: EQU 1H ;Bit to Test for Transmiter Ready.
MODSNDR: EQU 1H ;TxRDY bit TRUE
MODEREG: EQU MODDATP+2 ;2651 Mode Regs. 1&2 Port Address
CMDREG: EQU MODDATP+3 ;2651 Command Reg. Port Address
;
;
ORG 100H
;
; Change the clock speed if needed, to match your system
;
DS 3 ;(for "JMP START" instruction)
;
PMMIMODEM: DB NO ;yes=PMMI S-100 Modem 103H
SMARTMODEM: DB YES ;yes=HAYES Smartmodem, no=non-Hayes 104H
TOUCHPULSE: DB 'T' ;T=touch, P=pulse (Smartmodem-only) 105H
CLOCK: DB 20 ;clock speed in MHz x10, 25.5 MHz max. 106H
;20=2 MHh, 37=3.68 MHz, 40=4 MHz, etc.
MSPEED: DB 1 ;0=110 1=300 2=450 3=600 4=710 5=1200 107H
;6=2400 7=4800 8=9600 9=19200 default
BYTDLY: DB 5 ;0=0 delay 1=10ms 5=50 ms - 9=90 ms 108H
;default time to send character in ter-
;minal mode file transfer for slow BBS.
CRDLY: DB 5 ;0=0 delay 1=100 ms 5=500 ms - 9=900 ms 109H
;default time for extra wait after CRLF
;in terminal mode file transfer
NOOFCOL: DB 5 ;number of DIR columns shown 10AH
SETUPTST: DB YES ;yes=user-added Setup routine 10BH
SCRNTEST: DB YES ;Cursor control routine 10CH
ACKNAK: DB NO ;yes=resend a record after any non-ACK 10DH
;no=resend a record after a valid NAK
BAKUPBYTE: DB YES ;yes=change any file same name to .BAK 10EH
CRCDFLT: DB YES ;yes=default to CRC checking 10FH
TOGGLECRC: DB YES ;yes=allow toggling of CRC to Checksum 110H
CONVBKSP: DB NO ;yes=convert backspace to rub 111H
TOGGLEBK: DB NO ;yes=allow toggling of bksp to rub 112H
ADDLF: DB NO ;no=no LF after CR to send file in 113H
;terminal mode (added by remote echo)
TOGGLELF: DB YES ;yes=allow toggling of LF after CR 114H
TRANLOGON: DB YES ;yes=allow transmission of logon 115H
;write logon sequence at location LOGON
SAVCCP: DB YES ;yes=do not overwrite CCP 116H
LOCONEXTCHR: DB NO ;yes=local command if EXTCHR precedes 117H
;no=external command if EXTCHR precedes
TOGGLELOC: DB YES ;yes=allow toggling of LOCONEXTCHR 118H
LSTTST: DB YES ;yes=printer available on printer port 119H
XOFFTST: DB NO ;yes=checks for XOFF from remote while 11AH
;sending a file in terminal mode
XONWAIT: DB NO ;yes=wait for XON after CR while 11BH
;sending a file in terminal mode
TOGXOFF: DB YES ;yes=allow toggling of XOFF checking 11CH
IGNORCTL: DB YES ;yes=CTL-chars above ^M not displayed 11DH
EXTRA1: DB 0 ;for future expansion 11EH
EXTRA2: DB 0 ;for future expansion 11FH
BRKCHR: DB '@'-40H ;^@ = Send a 300 ms. break tone 120H
NOCONNCT: DB 'N'-40H ;^N = Disconnect from the phone line 121H
LOGCHR: DB 'L'-40H ;^L = Send logon 122H
LSTCHR: DB 'P'-40H ;^P = Toggle printer 123H
UNSAVE: DB 'R'-40H ;^R = Close input text buffer 124H
TRANCHR: DB 'T'-40H ;^T = Transmit file to remote 125H
SAVECHR: DB 'Y'-40H ;^Y = Open input text buffer 126H
EXTCHR: DB 'K'-40H ;^K = Send next character 127H
;
;
DS 2 ; 128H
;
IN$MODCTL1: IN MODCTL1 ! RET ;in modem control port 12AH
DS 7
OUT$MODDATP: OUT MODDATP ! RET ;out modem data port 134H
DS 7
IN$MODDATP: IN MODDATP ! RET ;in modem data port 13EH
DS 7
ANI$MODRCVB: ANI MODRCVB ! RET ;bit to test for receive ready 148H
CPI$MODRCVR: CPI MODRCVR ! RET ;value of rcv. bit when ready 14BH
ANI$MODSNDB: ANI MODSNDB ! RET ;bit to test for send ready 14EH
CPI$MODSNDR: CPI MODSNDR ! RET ;value of send bit when ready 151H
DS 12 ;PMMI only calls 154H
;
;
LOGONPTR: DW LOGON ;for user message. 160H
DS 6 ; 162H
JMP$GOODBYE: JMP GOODBYE ; 168H
JMP$INITMOD: JMP INITMOD ;go to user written routine 16BH
RET ! NOP ! NOP ;(by-passes PMMI routine) 16EH
RET ! NOP ! NOP ;(by-passes PMMI routine) 171H
RET ! NOP ! NOP ;(by-passes PMMI routine) 174H
JMP$SETUPR: JMP SETUPR ; 177H
JMP$SPCLMENU: JMP SPCLMENU ; 17AH
JMP$SYSVER: JMP SYSVER ; 17DH
JMP$BREAK: JMP SENDBRK ; 180H
;
;
; Do not change the following six lines.
;
JMP$ILPRT: DS 3 ; 183H
JMP$INBUF: DS 3 ; 186H
JMP$INLNCOMP: DS 3 ; 189H
JMP$INMODEM: DS 3 ; 18CH
JMP$NXTSCRN: DS 3 ; 18FH
JMP$TIMER: DS 3 ; 192H
;
;
; The following clear the screen for the H19 or H89 terminal
;
CLREOS: CALL JMP$ILPRT ; 195H
DB ESC,'J',0,0,0 ; 198H
RET ; 19DH
;
CLRSCRN: CALL JMP$ILPRT ; 19EH
DB ESC,'E',0,0,0 ; 1A1H
RET ; 1A6H
;
;
SYSVER: CALL JMP$ILPRT ; 1A7H
DB 'Version for Heath H8/H89 with 2651/2661'
DB CR,LF,'PCI - USART I/O - Rel 2.1'
DB CR,LF,0
RET
;.....
;
;
;-----------------------------------------------------------------------
;
; NOTE: You can change the SYSVER message to be longer or shorter. The
; end of your last routine should terminate by 0400H (601 bytes
; available after start of SYSVER) if using the Hayes Smartmodem
; or by address 0C00H (2659 bytes) otherwise.
;
;-----------------------------------------------------------------------
;
; You can put in a message at this location which can be called up with
; CTL-O if TRANLOGON has been set TRUE. You can put in several lines if
; desired. End with a 0.
;
LOGON: DB '70225,1220',CR,LF,0
;
;
; This routine sends a 300 ms. break tone to reset some time-share
; computers.
;
SENDBRK: MVI A,2FH ;SET BREAK TONE
OUT CMDREG
JMP GOODBYE1 ;SEND A 300 MS. BREAK TONE
;.....
;
;
; This routine sends a 300 ms. break tone and set DTR low for the same
; length of time to disconnect some modems such as the Bell 212A, etc.
;
GOODBYE: MVI A,0DH ;SET BREAK TONE, AND
OUT CMDREG ;RESET 'DTR' AND 'RTS' NOT TRUE
;
GOODBYE1: MVI B,3 ;WAIT 300 MS.
CALL JMP$TIMER
MVI A,27H ;RESET BREAK TO NORMAL, AND
OUT CMDREG ;SET 'DTR', AND 'RTS' TRUE
RET
;.....
;
;
; The following is used to initialize the H8 2651/2661 MODEM I/O port
; at 340Q.
;
INITMOD: MVI A,1 ;default transfer speed to 300 baud
STA MSPEED
DI ;turn off interrupts for init.
MVI A,4EH ;16x Baud Rate Factor, 8 Data Bits,
;No Parity, 1 Stop Bit.
OUT MODEREG ;Set up Mode Reg. 1.
LSPSPD: MVI A,35H ;default to 300 baud, Internal clocks.
OUT MODEREG ;Set up Mode Reg. 2.
;
MVI A,27H ;Set 'DTR', 'RTS', RxEN, and TxEN True.
OUT CMDREG ;Set up Modem Port Command Register.
EI ;restore interrupts to normal
RET
;.....
;
;
; The following routine changes the baud rate for the H8 with the SET
; command.
;
SETUPR: LXI D,BAUDBUF ;point to input buffer for INLNCOMP
CALL JMP$ILPRT
DB 'Input Baud Rate (300, 600, 1200, 2400, 4800, 9600): ',0
CALL JMP$INBUF
LXI D,BAUDBUF+2
CALL JMP$INLNCOMP ;compare BAUDBUF+2 with characters below
DB '300',0
JNC OK300 ;go if got match
CALL JMP$INLNCOMP
DB '600',0
JNC OK600
CALL JMP$INLNCOMP
DB '1200',0
JNC OK1200
CALL JMP$INLNCOMP
DB '2400',0
JNC OK2400
CALL JMP$INLNCOMP
DB '4800',0
JNC OK4800
CALL JMP$INLNCOMP
DB '9600',0
JNC OK9600
CALL JMP$ILPRT ;NO MATCH - tell operator
DB '++ INCORRECT ENTRY ++',CR,LF,BELL,0
JMP SETUPR ;try again
;
OK300: MVI A,1 ;MSPEED Baud Rate Value
LXI H,BD300 ;Point to Baud Rate Parameter's Table Add.
JMP LOADBD ;Go Store It.
;
OK600: MVI A,3
LXI H,BD600
JMP LOADBD
;
OK1200: MVI A,5
LXI H,BD1200
JMP LOADBD
;
OK2400: MVI A,6
LXI H,BD2400
JMP LOADBD
;
OK4800: MVI A,7
LXI H,BD4800
JMP LOADBD
;
OK9600: MVI A,8
LXI H,BD9600
;
LOADBD: STA INITMOD+1 ;store speed to show transfer time
MOV A,M ;Get Baud Rate Byte From Table.
STA LSPSPD+1 ;store in INITMOD
JMP INITMOD ;reset-up H8 2651 Mode Registers.
;
;
; Table of baud rate parameters
;
BD300: DB 35H
BD600: DB 36H
BD1200: DB 37H
BD2400: DB 3AH
BD4800: DB 3CH
BD9600: DB 3EH
;
BAUDBUF: DB 10,0
DS 10
;
;-----------------------------------------------------------------------
;
; This routine can be used for your equipment, be sure to end with RET
; If using the Hayes Smartmodem this is unavailable without a special
; change.
;
SPCLMENU: RET
;
;-----------------------------------------------------------------------
;
;
; NOTE: MUST TERMINATE PRIOR TO 0400H (with Smartmodem)
; 0C00H (without Smartmodem)
;
END
;
-------------
;
;
; NOTE: MUST TERMINATE PRIOR TO 0400H (with Smartm