home
***
CD-ROM
|
disk
|
FTP
|
other
***
search
/
ftp.barnyard.co.uk
/
2015.02.ftp.barnyard.co.uk.tar
/
ftp.barnyard.co.uk
/
cpm
/
walnut-creek-CDROM
/
CPM
/
MODEMS
/
MODEM7
/
M7C3-1.AQM
/
M7C3-1.ASM
Wrap
Assembly Source File
|
2000-06-30
|
9KB
|
338 lines
; M7C3-1.ASM -- CP/M Plus overlay file for MODEM7. 11/19/83
;
; This overlay adapts the MODEM7 program to use the auxiliary device
; in CP/M Version 3.
;
; You will want to look this file over carefully. There are a number of
; options that you can use to configure the program to suit your taste.
; This file places particular emphasis on using the Auxiliary device
; properly configured under CP/M 3.
;
;
; Edit this file for your preferences then follow the "TO USE:" example
; shown below.
;
; TO USE: First edit this file filling in answers for your own
; equipment. Then assemble with MAC.COM or equivalent
; assembler. Then use SID to overlay the the results
; of this program to the original .COM file:
;
; A>SID MDM712
; CP/M 3 SID - Version 3.0
; NEXT MSZE PC END
; 4300 4300 0100 D3FF
; #E M7C3-1.HEX ("E" loads in the .HEX file)
; NEXT MSZE PC END
; 031E 4300 0100 D3FF
; #W MDM712.COM,100,42FF ("W" writes the modified .COM file)
; 0084h record(s) written
; #G0 (return to CP/M)
;
; = = = = = = = = = = = = = = = = = =
;
; 11/19/83 - Edited M712GP.ASM for this file - Jim Lopushinsky
;
; = = = = = = = = = = = = = = = = =
;
BELL: EQU 07H ;bell
CR: EQU 0DH ;carriage return
ESC: EQU 1BH ;escape
LF: EQU 0AH ;linefeed
;
YES: EQU 0FFH
NO: EQU 0
;
;
; Change the following information to match your equipment
;
BDOS: EQU 5
DEVICE: EQU 1 ;CP/M's MODEM device number
;
ORG 100H
;
;
; Change the clock speed to suit your system
;
DS 3 ;(for "JMP START" instruction)
;
PMMIMODEM: DB NO ;yes=PMMI S-100 Modem 103H
SMARTMODEM: DB YES ;yes=HAYES Smartmodem, no=non-PMMI 104H
TOUCHPULSE: DB 'T' ;T=touch, P=pulse (Smartmodem-only) 105H
CLOCK: DB 40 ;clock speed in MHz x10, 25.5 MHz max. 106H
;20=2 MHh, 37=3.68 MHz, 40=4 MHz, etc.
MSPEED: DB 1 ;0=110 1=300 2=450 3=600 4=710 5=1200 107H
;6=2400 7=4800 8=9600 9=19200 default
BYTDLY: DB 5 ;0=0 delay 1=10ms 5=50 ms - 9=90 ms 108H
;default time to send character in ter-
;minal mode file transfer for slow BBS.
CRDLY: DB 5 ;0=0 delay 1=100 ms 5=500 ms - 9=900 ms 109H
;default time for extra wait after CRLF
;in terminal mode file transfer
NOOFCOL: DB 5 ;number of DIR columns shown 10AH
SETUPTST: DB YES ;yes=user-added Setup routine 10BH
SCRNTEST: DB YES ;Cursor control routine 10CH
ACKNAK: DB YES ;yes=resend a record after any non-ACK 10DH
;no=resend a record after a valid-NAK
BAKUPBYTE: DB NO ;yes=change any file same name to .BAK 10EH
CRCDFLT: DB YES ;yes=default to CRC checking 10FH
TOGGLECRC: DB YES ;yes=allow toggling of CRC to Checksum 110H
CONVBKSP: DB NO ;yes=convert backspace to rub 111H
TOGGLEBK: DB YES ;yes=allow toggling of bksp to rub 112H
ADDLF: DB NO ;no=no LF after CR to send file in 113H
;terminal mode (added by remote echo)
TOGGLELF: DB YES ;yes=allow toggling of LF after CR 114H
TRANLOGON: DB YES ;yes=allow transmission of logon 115H
;write logon sequence at location LOGON
SAVCCP: DB NO ;yes=do not overwrite CCP 116H
LOCONEXTCHR: DB NO ;yes=local command if EXTCHR precedes 117H
;no=external command if EXTCHR precedes
TOGGLELOC: DB YES ;yes=allow toggling of LOCONEXTCHR 118H
LSTTST: DB YES ;yes=printer available on printer port 119H
XOFFTST: DB NO ;yes=checks for XOFF from remote while 11AH
;sending a file in terminal mode
XONWAIT: DB NO ;yes=wait for XON after CR while 11BH
;sending a file in terminal mode
TOGXOFF: DB YES ;yes=allow toggling of XOFF checking 11CH
IGNORCTL: DB YES ;yes=CTL-chars above ^M not displayed 11DH
EXTRA1: DB 0 ;for future expansion 11EH
EXTRA2: DB 0 ;for future expansion 11FH
BRKCHR: DB '@'-40H ;^@ = Send 300 ms. break tone 120H
NOCONNCT: DB 'N'-40H ;^N = Disconnect from the phone line 121H
LOGCHR: DB 'L'-40H ;^L = Send logon 122H
LSTCHR: DB 'P'-40H ;^P = Toggle printer 123H
UNSAVE: DB 'R'-40H ;^R = Close input text buffer 124H
TRANCHR: DB 'T'-40H ;^T = Transmit file to remote 125H
SAVECHR: DB 'Y'-40H ;^Y = Open input text buffer 126H
EXTCHR: DB '^'-40H ;^^ = Send next character 127H
;
;
DS 2 ; 128H
;
IN$MODCTL1: RET ; 12AH
DS 9
OUT$MODDATP: JMP AUXOUT ;out modem data port 134H
DS 7
IN$MODDATP: JMP AUXIN ;in modem data port 13EH
DS 7
ANI$MODRCVB: RET ; 148H
DS 2
CPI$MODRCVR: JMP AUXINST ;value of rcv. bit when ready 14BH
ANI$MODSNDB: RET ; 14EH
DS 2
CPI$MODSNDR: JMP AUXOUTST ;value of send bit when ready 151H
DS 6 ; 156H
;
OUT$MODCTL1: RET ; 15AH
DS 2
OUT$MODCTL2: RET ; 15DH
DS 2
;
LOGONPTR: DW LOGON ;for user message. 160H
DS 6 ; 162H
JMP$GOODBYE: JMP GOODBYE ; 168H
JMP$INITMOD: JMP INITMOD ;go to user written routine 16BH
RET ! NOP ! NOP ;(by-passes PMMI routine) 16EH
RET ! NOP ! NOP ;(by-passes PMMI routine) 171H
RET ! NOP ! NOP ;(by-passes PMMI routine) 174H
JMP$SETUPR: JMP SETUPR ; 177H
JMP$SPCLMENU: JMP SPCLMENU ; 17AH
JMP$SYSVER: JMP SYSVER ; 17DH
JMP$BREAK: JMP SENDBRK ; 180H
;
;
; Do not change the following six lines.
;
JMP$ILPRT: DS 3 ; 183H
JMP$INBUF DS 3 ; 186H
JMP$INLNCOMP: DS 3 ; 189H
JMP$INMODEM DS 3 ; 18CH
JMP$NXTSCRN: DS 3 ; 18FH
JMP$TIMER DS 3 ; 192H
;
;
; Routine to clear to end of screen. If using CLREOS and CLRSCRN, set
; SCRNTEST to YES at 010AH (above).
;
CLREOS: CALL JMP$ILPRT ; 195H
DB ESC,'k',0,0,0 ;Setup for Adds Viewpoint 198H
RET ; 19DH
;
CLRSCRN: CALL JMP$ILPRT ; 19EH
DB 12,0,0,0,0 ;Setup for Adds Viewpoint 1A1H
RET ; 1A6H
;
SYSVER: CALL JMP$ILPRT ; 1A7H
DB 'Version for CP/M Plus (Device '
DB DEVICE+'0',')'
DB CR,LF,0
RET
;.....
;
;
;-----------------------------------------------------------------------
;
; NOTE: You can change the SYSVER message to be longer or shorter. The
; end of your last routine should terminate by 0400H (601 bytes
; available after start of SYSVER) if using the Hayes Smartmodem
; or by address 0C00H (2659 bytes) otherwise.
;
;-----------------------------------------------------------------------
;
; You can put in a message at this location which can be called up with
; CTL-O if TRANLOGON has been set TRUE. You can use several lines if
; desired. End with a 0.
;
LOGON: DB 'The cow jumped over the moon',CR,0
;.....
;
;
; Add your own routine here to send a break tone to reset some time-share
; computers, if desired.
;
SENDBRK: RET
;.....
;
;
; Add your own routine here to put DTR low and/or send a break tone.
; Check other routines such as MDM709DP.ASM which is using this feature.
;
GOODBYE: RET
;.....
;
;
; You can use this area for any special initialization or setup you may
; wish to include. Each must stop with a RET. You can check the other
; available overlays for ideas how to write your own routines if that
; may be of some help.
;
INITMOD: MVI C,12
CALL BDOS ;Get version #
CPI 30H
JNC ISCPM3
CALL JMP$ILPRT
DB 'Requires CP/M Version 3',CR,LF,0
RST 0
ISCPM3: MVI A,20 ;BIOS return character I/O table function
STA FUNC
MVI C,50
LXI D,FUNC
CALL BDOS
PUSH H ;Save the table address for later
LXI H,7 ;Offset to baud rate
MVI A,DEVICE
ORA A
JZ ISZERO
LXI D,8
DEVLP: DAD D
DCR A
JNZ DEVLP
ISZERO: POP D ;Get Table address
DAD D ;Form baud rate address
SHLD BAUDAD
RET
;
SETUPR: CALL JMP$ILPRT
DB 'Input Baud Rate (300, 1200, 9600 ,19200): ',0
LXI D,BAUDBUF
CALL JMP$INBUF
LXI D,BAUDBUF+2
CALL JMP$INLNCOMP
DB '300',0
JNC OK300
CALL JMP$INLNCOMP
DB '1200',0
JNC OK1200
CALL JMP$INLNCOMP
DB '9600',0
JNC OK9600
CALL JMP$INLNCOMP
DB '19200',0
JNC OK19200
CALL JMP$ILPRT
DB '++ Incorrect entry ++',CR,LF,BELL,0
JMP SETUPR
OK300: MVI A,1
MVI B,6
JMP LOADBD
OK1200: MVI A,5
MVI B,8
JMP LOADBD
OK9600: MVI A,8
MVI B,14
JMP LOADBD
OK19200: MVI A,9
MVI B,15
LOADBD: STA MSPEED
LHLD BAUDAD
MOV M,B
LXI H,DEVICE
SHLD BCREG
MVI A,21
STA FUNC
MVI C,50
LXI D,FUNC
JMP BDOS
AUXIN: DB 0D9H ;EXX
MVI C,3
CALL BDOS
DB 0D9H ;EXX
RET
AUXOUT: DB 0D9H ;EXX
MVI C,4
MOV E,A
PUSH PSW
CALL BDOS
POP PSW
DB 0D9H ;EXX
RET
AUXINST: DB 0D9H ;EXX
MVI C,7
CALL BDOS
DB 0D9H ;EXX
INR A ;Reverse sense
RET
AUXOUTST: DB 0D9H ;EXX
MVI C,8
CALL BDOS
DB 0D9H ;EXX
INR A ;Reverse sense
RET
BAUDBUF: DB 10,0
DS 2
FUNC: DS 1
AREG: DS 1
BCREG: DS 2
DEREG: DS 2
HLREG: DS 2
BAUDAD: DS 2
;
;
; If using the Hayes Smartmodem this is unavailable without a special
; change.
;
SPCLMENU: RET
;
;
; NOTE: MUST TERMINATE PRIOR TO 0400H (with Smartmodem)
; 0C00H (without Smartmodem)
;.....
;
END
;