home *** CD-ROM | disk | FTP | other *** search
/ ftp.barnyard.co.uk / 2015.02.ftp.barnyard.co.uk.tar / ftp.barnyard.co.uk / cpm / walnut-creek-CDROM / CPM / MODEMS / MODEM / HAYS1200.FIX < prev    next >
Internet Message Format  |  2000-06-30  |  4KB

  1. Date: Saturday, 14 April 1984
  2. From: Russ Smith
  3. To:   net.micro
  4. Re:   modems and heat problems
  5.  
  6. A while back I posted a request for help concerning problems I was 
  7. having using MDM7xx on a homebuilt z80 based machine with a Hayes 1200 
  8. Smartmodem and an h-19 terminal. The problem was that I could hook the 
  9. Hayes directly to the terminal and talk both ways to another machine 
  10. without any problem but if I hooked the Hayes and the h-19 to my 
  11. machine I could only send stuff to the other machine, received stuff 
  12. being totally garbaged. The problem seemed to go away after I just 
  13. turned everything off and reseated boards...it didn't.
  14.  
  15. Well, the recent net traffic about modem heating problems got my 
  16. synapses firing...
  17.  
  18. I took the front cover off the Hayes, placed a muffin fan blowing at it 
  19. about 4" away, and all symptoms have "permanently" disappeared.
  20.  
  21. Apparently my chicken-wire-and-spit homebuilt machine is close to the 
  22. limit with the "receive data from modem" baudrate. Hence when the Hayes 
  23. started drifting due to heat, the received characters started getting 
  24. garbaged (framing error). This caused the modem-to-computer-to-terminal 
  25. setup to go south. When I "reseated" the boards, I had to turn 
  26. everything off, thus giving the Hayes time to cool down and causing the 
  27. problem to go away (temporarily). This red herring behavior led me 
  28. astray until I read the recent net stuff.
  29.  
  30. When just hooked in as a modem-to-terminal setup everything worked 
  31. okay, so I have to conclude that the h-19, using newer technology 
  32. (software programmable UART), is more tolerant of out-of-spec received 
  33. baudrate than my "old" hardware-programmable-UART-based Godbout 
  34. Interfacer (sans II (inside "joke"...))
  35.  
  36. Now the problem is to find a way to sufficiently cool down the Hayes 
  37. without the silly muffin fan...
  38.  
  39. Keep them informative messages coming, they've helped more than once,
  40.  
  41. Russ Smith
  42.  
  43. Date: Tuesday, 10 April 1984
  44. From: hplabs!sdcrdcf!darrelj
  45. To:   net.micro
  46. Re:   Hayes 1200 Problems
  47.  
  48. First note that the bit pattern in 'U' is 01010101.  What can happen is 
  49. that since the modem actually sends of four states for PAIRS of bits, 
  50. noise can  occasionally get one of the modems out of proper sync with 
  51. the data stream.  Another thing which can happen is that the Bell 212 
  52. protocol includes a way to put the far end modem into a loop-back self-
  53. test mode (and occasionally noise will mimic the sequence).  In fact 
  54. this just happened to me while reading about other 1200 bps problems 
  55. (symptom: first, about 20 Us, then remote end started loopback, echoing 
  56. exactly what I typed, notable in that RETURN comes back without the 
  57. LINEFEED that unix adds), and I fixed it on my old Prentice 212 by 
  58. turning the Remote-Digital-Loop control on and off, taking the remote 
  59. modem out of loopback mode.  Or course most of the new cheap 212 
  60. compatibles save some of the money by taking out all the switches (the 
  61. prentice has 5 on front panel, ~40 internal, plus 10 LEDs and output 
  62. level programmable with an external (TELCO provided) resistor).  The 
  63. cheap modems will work in 95% of applications and on 95% of phone lines 
  64. instead of all applications and 99% of lines.  Generally, an acceptible 
  65. tradeoff.
  66. -- 
  67. Darrel J. Van Buer, PhD
  68. System Development Corp.
  69. 2500 Colorado Ave
  70. Santa Monica, CA 90406
  71. (213)820-4111 x5449
  72. ...{allegra,burdvax,cbosgd,hplabs,ihnp4,sdccsu3,trw-unix}!sdcrdcf!darrelj
  73.  
  74.  
  75. Date: Monday, 9 April 1984  20:07-MST
  76. From: decvax!ittvax!dcdwest!sdcsvax!sdchema!bam
  77. To:   net.micro
  78. Re:   Hayes 1200 Problems
  79.  
  80. The Hayes Smartmodem 1200 had a firmware problem where it would hang in 
  81. a locked state under certain conditions.  This could usually be 
  82. remedied only by power on reset.
  83.  
  84. If this is what is actually going on, call Hayes and they will fix it 
  85. for you free of charge.
  86.  
  87. Bret Marquis
  88. -- 
  89. Bang World Communication Center - San Diego.
  90.