; I2MIC-1.ASM - Multitech MIC 504 overlay for IMP - 11/08/88
;
; MIC 504 uses the Z80 DART & CTC timer (3.6864 MHz)
;
; You will want to look this file over carefully. There are a number of
; options that you can use to configure the program to suit your taste.
; This file adapts the RS-232 port on the Multitech MIC 504 to IMP.COM.
;
; Edit this file for your preferences then follow the "TO USE:" example
; shown below.
;
; Many terminals will clear the screen with a CTL-Z. If yours does, put
; a 1AH at CLEAR: (010AH). Many terminals use two characters, the first
; normally an ESC. For example, ESC *. In this case put '*' at CLEAR:
; (The ESC will automatically be typed with no CTL-character present.)
; If you don't know what your terminal uses, put a 0 at CLEAR: and IMP
; will scroll up 24 blank lines to clear the CRT for things like MENU,
; looking at the function key table, typing CTL-Z in command mode, etc.
;
; Use the "SET" command to change the baud rate when desired. The value
; at MSPEED controls the baudrate when the program is first called up.
;
; TO USE: First edit this file filling in answers for your own
; equipment. Then assemble with ASM.COM or equivalent
; assembler.
;
; A>MLOAD IMP.COM=IMP.COM,I2MIC-x.HEX
;
; = = = = = = = = = = = = = = = = = =
;
;
; 11/08/88 Adapted from I2TV-5.ASM. -Ian Justman
;
; = = = = = = = = = = = = = = = = =
;
;
YES EQU 0FFH
NO EQU 0
;
;
; Select one of the following four choices for your computer
;
;
;
PORT EQU 88H ; MIC 504 Z80 DART base port (data or status)
MDCTL1 EQU PORT+2 ; Modem control port
MDDATP EQU PORT ; Modem data port
MDRCV EQU 01H ; Modem receive ready
MDSND EQU 04H ; Modem send ready bit
MDTXE EQU 01H ; Modem send buffer empty, holding buffer empty
BDPORT EQU 85H ; CTC port for baud rate
;
;-----------------------------------------------------------------------
;
ESC EQU '['-40H ; ^[ = Escape
BELL EQU 'G'-40H ; ^G = Bell character
LF EQU 'J'-40H ; ^J = Linefeed
NEXTRY EQU 'K'-40H ; ^K = Try next phone number, abort this try
CR EQU 'M'-40H ; ^M = Carriage return
CLEARSC EQU 'Z'-40H ; ^Z = Clears screen, command mode only
EOFCHAR EQU 'Z'-40H ; ^Z = End of file
;
;-----------------------------------------------------------------------
;
;
ORG 0100H
;
;
DS 3 ; Skip the data area below
;
;
; These routines and equates are at the beginning of the program so
; they can be patched by a monitor or overlay file without re-assembling
; the program.
;
MSPEED: DB 5 ; 0=110 1=300 2=450 3=600 4=710 5=1200 103H
; 6=2400 7=4800 8=9600 9=19200 default
HS2400: DB NO ; Yes=2400 bps highest speed 104H
HS1200: DB YES ; Yes=1200 bps highest speed 105H
RACAL: DB NO ; Yes=Racal-Vadic 1200V or 2400V or 2400PA 106H
PROMODM: DB NO ; Yes=Prometheus ProModem 1200 bps 107H
RESVD1: DB NO ; Reserved for special modems 108H
RESVD2: DB NO ; Reserved for special modems 109H
;
;
CLEAR: DB '*' ; Clear screen character (ESC not needed) 10AH
CLOCK: DB 37 ; Clock speed in MHz x10, 25.5 MHz max. 10BH
; 20=2 MHh, 37=3.68 MHz, 40=4 MHz, etc.
BYTDLY: DB 2 ; 0=0 delay 1=10ms 5=50 ms - 9=90 ms 10CH
; default time to send character in ter-
; minal mode file transfer for slow BBS
CRDLY: DB 2 ; 0=0 delay 1=100 ms 5=500 ms - 9=900 ms 10DH
; default time for extra wait after CRLF
; in terminal mode file transfer
NOFCOL: DB 5 ; Number of directory columns shown 10EH
TCHPUL: DB 'T' ; T=tone, P=Pulse (Hayes 2400 modems) 10FH
;.....
;
;
ADDLFD: DB NO ; Yes=add LF after CR to send file in terminal 110H
; mode (normally added by remote echo)
CONVRUB: DB YES ; Yes=convert rub to backspace 111H
CRCDFLT: DB YES ; Yes=default to CRC checking 112H
IGNRCTL: DB YES ; Yes=CTL-chars above ^M not displayed 113H
;.....
;
;
EXTCHR: DB '['-40H ; ESC = preceeds local control character 114H
EXITCHR: DB 'E' ; Exit character 115H
FILESND: DB 'F' ; Send file when in terminal mode 116H
NOCONCT: DB 'N' ; Disconnect from phone line 117H
LOGCHR: DB 'L' ; Send logon 118H
LSTCHR: DB 'P' ; Toggle printer 119H
UNSAVCH: DB 'R' ; Close input text buffer 11AH
SAVECHR: DB 'Y' ; Open input text buffer 11BH
CLEARS: DB 'Z' ; Clears screen, terminal mode 11CH
BRKCHR: DB 'Q' ; Send a break tone 11DH
NODTR: DB NO ; YES if no DTR and need ATH0 to disconnect 11EH
;.....
;
;
; Handles in/out ports for data and status
;
I$MDCTL1:
MVI A,10H ; 11FH
OUT MDCTL1 ; 121H
IN MDCTL1 ; 123H
RET ; 125H
DB 0,0,0 ; 126H
I$MDTXE:
MVI A,11H ; Read register 1 for "all sent" 129H
OUT MDCTL1 ; 12BH
IN MDCTL1 ; 12DH
RET ; 12FH
DB 0,0,0 ; 130H
I$MDDATP: IN MDDATP ; 133H
RET ; 135H
DB 0,0,0,0,0,0,0 ; 136H
;
O$MDDATP: OUT MDDATP ; 13DH
RET ; 13FH
DB 0,0,0,0,0,0,0 ; Spares if needed 140H
;.....
;
;
A$MDRCV: ANI MDRCV ; 147H
RET ; 149H
;
C$MDRCV: CPI MDRCV ; 14AH
RET ; 14CH
;
A$MDSND: ANI MDSND ; 14DH
RET ; 14FH
;
C$MDSND: CPI MDSND ; 150H
RET ; 152H
;
A$MDTXE: ANI MDTXE ; 153H
RET ; 155H
;
C$MDTXE: CPI MDTXE ; 156H
RET ; 158H
;.....
;
;
; Special exit vector, used by some computers to reset interrupt vectors
;
J$EXITVEC:RET ; 159H
DB 0,0 ; 15AH
;.....
;
;
; Jump vectors needed by each overlay
;
J$GOODBYE:JMP GOODBYE ; Disconnects modem by dropping DTR 15CH
J$INITMOD:JMP INITMOD ; Initializes modem, autosets baudrate 15FH
J$STUPR: JMP STUPR ; SET routine to change baudrate 162H
J$SYSVR: JMP SYSVR ; Signon message 165H
;.....
;
;
; "AT" command strings, can be replaced in individual overlay if needed
;
J$STRNGA: DS 3 ; 1200 bps "AT" string 168H
J$STRNG1: DS 3 ; 2400 bps "AT" string 16BH
;
;
; Next fourteen lines should not be changed by user overlay as these go
; to specific locations in the main program, not in the overlay.
;
;
J$CMDSPL: DS 3 ; Allows entry of baudrate on CMD line 16EH
J$CRLF: DS 3 ; Turns up one new line on display 171H
J$DIAL: DS 3 ; Start of dialing routine 174H
J$DSCONT: DS 3 ; Terminates modem use 177H
J$GOLST: DS 3 ; Printer routine, needed by Apple //e 17AH
J$ILPRT: DS 3 ; Prints an inline string, 0 to end 17DH
J$INBUF: DS 3 ; Stores a keybd string for comparison 180H
J$INLNCP: DS 3 ; Inline "compare strings" routine 183H
J$INMDM: DS 3 ; Max .1 sec wait for modem character 186H
J$RCVRSP: DS 3 ; For 3801 I/O use (TV-803) 189H
J$SNDCHR: DS 3 ; Sends a character to the modem 18CH
J$SNDSTR: DS 3 ; Sends a string to the modem, $ to end 18FH
J$TIMER: DS 3 ; .1 second timer (amount in 'B' reg.) 192H
J$BREAK: JMP SENDBRK ; Break routine 195H
J$NEW2: DB 0,0,0 ; For future needs 198H
;.....
;
;
; For 2400 bps auto-stepdown units
;
MANUAL: DB 0 ; For manual selection flag 19BH
J$300: JMP OK300 ; Sets baudrate to 300 baud 19CH
J$1200: JMP OK1200 ; Sets baudrate to 1200 bps 19FH
J$2400: JMP OK2400 ; Sets baudrate to 2400 bps 1A2H
;.....
;
;
LOGPTR: DW LOGON ; Pointer to display LOGON message 1A5H
;
SYSVR: CALL J$ILPRT ; Display the following line 1A7H
DB 'Version for Multitech MIC 504 port 88H' ; 1AAH
DB CR,LF,0
;
;
;-----------------------------------------------------------------------
;
; NOTE: You can change the SYSVER message to be longer or shorter. The
; end of your last routine should terminate by 0400H (601 bytes
; available after start of SYSVER).
;
;-----------------------------------------------------------------------
;
; You can put in a message at this location which can be called up with
; (special character-L). You can put in several lines. End with a 0.
;
LOGON: DB 'Greetings from a Multitech user',CR,LF,0
;
;-----------------------------------------------------------------------
;
; This routine sets a 300 ms break tone
;
SENDBRK:
MVI A,5
OUT MDCTL1 ; Send to the status port
MVI A,0F8H ; DTR normal, send break tone
JMP GOODBYE1 ; Go send the break tone
;
;.....
;
;
; This routine sets DTR low for 300 ms to disconnect the phone
;
GOODBYE:
MVI A,5
OUT MDCTL1 ; Send to the status port
MVI A,068H ; Turn off DTR, send break
;
GOODBYE1:
OUT MDCTL1
MVI B,3 ; Wait 300 ms
CALL J$TIMER
MVI A,5
OUT MDCTL1
MVI A,0E9H ; Restore normal, 8 bits, DTR on, etc.
OUT MDCTL1
;
;.....
;
;
; Multitech MIC 504 baud rate change. Sets CTC timer for baudrate.
;
INITMOD:
MVI A,0 ; Select register
OUT MDCTL1 ; Send to the status port
MVI A,18H ; Reset the Z80 dart chip
OUT MDCTL1 ; Send to the status port
MVI A,4 ; Select register
OUT MDCTL1 ; Send to the status port
MVI A,44H ; 16x, 1-stop, no parity (44=1, 4C=2)
OUT MDCTL1 ; Send to the status port
MVI A,3 ; Select register
OUT MDCTL1 ; Send to the status port
MVI A,0C1H ; Enable receive section
OUT MDCTL1 ; Send to the status port
MVI A,5 ; Select register
OUT MDCTL1 ; Send to the status port
MVI A,0EAH ; DTR, RTS, 8-bits, enable send section
OUT MDCTL1 ; Send to the status port
;
;
LDA MSPEED ; Get the selected value
CPI 1 ; 300 bps
JZ OK300
CPI 5 ; 1200 bps
JZ OK1200
CPI 6 ; 2400 bps
JZ OK2400
CPI 8 ; 9600 bps
JZ OK9600
CPI 9 ; 19200
JZ OK19200
JMP STUPR1 ; Else ask what is wanted
;.....
;
;
STUPR: CALL J$CMDSPL ; Gives us CMDBUF+6
JNC STUPR2
;
STUPR1: CALL J$ILPRT
DB 'Input Baud Rate (300, 1200, 2400, 9600, 19200): ',0
LXI D,BAUDBUF ; Point to new input buffer
CALL J$INBUF
CALL J$CRLF
LXI D,BAUDBUF+2
;
STUPR2: CALL J$INLNCP ; Compare BAUDBUF+2 with chars. below
DB '300',0
JNC OK300 ; Go if got match
CALL J$INLNCP
DB '1200',0
JNC OK1200
CALL J$INLNCP
DB '2400',0
JNC OK2400
CALL J$INLNCP
DB '9600',0
JNC OK9600
CALL J$INLNCP
DB '19200',0
JNC OK19200
CALL J$ILPRT ; All matches failed, tell operator
DB '++ Incorrect entry ++',CR,LF,BELL,CR,LF,0
JMP STUPR1 ; Try again
;
OK300: MVI A,1 ; MSPEED 300 baud value
LXI H,BD300
JMP LOADBD
;
OK1200: MVI A,5
LXI H,BD1200
JMP LOADBD
;
OK2400: XRA A ; Reset flag for automatic selection
STA MANUAL
MVI A,6
LXI H,BD2400
JMP LOADBD
;
OK9600: MVI A,8
LXI H,BD9600
JMP LOADBD
;
OK19200:MVI A,9
LXI H,BD19200
;
LOADBD: STA MSPEED ; Change time-to-send to match baudrate
MOV A,H ; CTC timer control word
OUT BDPORT ; Controls CTC timer/counter
MOV A,L ; Baudrate
OUT BDPORT
RET
;.....
;
;
; Baudrate table
;
BD300 EQU 4780H ; 38400/300 converted to hex value
BD1200 EQU 4720H ; 38400/1200 converted to hex value
BD2400 EQU 4710H ; 38400/2400 converted to hex value
BD9600 EQU 4704H ; 38400/9600 converted to hex value
BD19200 EQU 4702H ; 38400/19200 converted to hex value
;
;
BAUDBUF:DB 10,0,0,0,0,0
DB 0,0,0,0,0,0
;.....
;
; end
;-----------------------------------------------------------------------
;
; Note: Must end by 0400H