  1. On June 18,1985 IBM issued the following advisory:
  2. IBM has determined that a faulty component on less than 10%
  3. of Fixed Disk/Diskette Drive Adapters may cause problems with
  4. data storage on the fixed disk drive.
  5. IBM AT's affected are in the following serial number ranges;
  6. Model 068      5019001 to 5141250
  7. Model 099      0054001 to 0146900
  8. only a limited number of these units are affected.
  9. Two methods of inspection are provided.
  10. 1 - FD/DD Adapter Test Program
  11.     run the program- every few seconds an asterisk will appear on screen
  12.     to indicate normal progress. The test takes 60 minutes to complete.
  13.     At the end, results will appear on your screen.
  14. 2 - Visual inspection
  15.     All FD/DD Adapter cards with a TI chip with a -10 suffix in position
  16.     U-19 (near the "front" of the machine about three chips down from the
  17.     top), should be replaced.
  18. IBM also notes that users who require replacement should be informed that
  19. they could lose data on their fixed disk when replacing the adapter.
  20. All this is pretty much verbatim per IBM System Support Guide dated
  21. July,1985.