SUBROUTINE ENDRUN (IPASS)
C SUBROUTINE ENDRUN (IPASS, XHUM1,COMFTS)
C
C-----PERFORMS CALCULATIONS FOR THE END OF THE RUN
C
C-----CONSTANTS
CMDK NHRO
CMDK NHRP
CMDK NOUTDY
CMDK NZN
CMDK NZN7
C
C-----COMMON BLOCKS
CMDK BLKSV
CMDK HUMIDC
CMDK OUTPUT
CMDK QUAYCH
CMDK QUAYLE
CMDK TSTATC
INTEGER IPASS (NOUTDY)
C REAL XHUM1(22),COMFTS(11,21)
C
DO 1170 I=1, NOUTDY
IF (IPASS (I).EQ.0) SEASUM (I)=SEASUM (I)/NMONTH
1170 CONTINUE
SEASUM (15)=RATIO (SEASUM (10), SEASUM (14), 1.0)
SEASUM (32)=RATIO (SEASUM (27), SEASUM (31), 0.001)
CALL QACCUML
WRITE(60, 6000) ICITY, (CMONTH (MONTH (I)), I=1, NMONTH)
WRITE(60, 4010) REDC, REDH
WRITE(60, 6060) IDES
WRITE(60, 6010) (SEASUM (I), I=1, 5)
IF (MODE.NE.2) THEN
WRITE(60, 6020) (SEASUM (I), I=6, 15)
END IF
IF (MODE.NE.3) THEN
WRITE(60, 6030) (SEASUM (I), I=25, 32)
END IF
IF (CFMBP.GT.0.0) WRITE(60, 6070) (SEASUM (I), I=33, 38)
C IF (ICOMF.NE.1) THEN
C WRITE(60, 5100)
C DO 1200 J=1, 21
C J1=J+1
C J22=22-J
C WRITE(60, 6050) XHUM1 (J), XHUM1 (J1),
C 1 (COMFTS (I, J22), I=1, 11)
C 1200 CONTINUE
C END IF
C
4010 FORMAT (' BASE UNIT COOLING CAPACITY MULTIPLIED BY ', F10.3, /,
1 ' BASE UNIT HEATING CAPACITY MULTIPLIED BY ', F10.3)
5100 FORMAT ('1', T28, 'TIME SPENT IN EACH COMFORT ZONE (HRS)', /,
1 ' SP.HUM.', T35, 'DRYBULB TEMPERATURE', /,
2 T13, '65/67 67/69 69/71 71/73 73/75 75/77 77/79 79/81',
3 ' 81/83 83/85 85/125', /)
C *** SEASONAL SUMMARY OUTPUT
6000 FORMAT ('1 ***SEASONAL SUMMARY FOR ', A4, '***', /,
1 '0SEASON IN: ', 12 (A4, 1X))
6010 FORMAT (' MEAN ROOM TEMPERATURE', T48, 'DEGF', F12.1, /,
1 ' MEAN ROOM RELATIVE HUMIDITY', T51, '%', F12.1, /,
2 ' MEAN OUTDOOR DRY BULB', T48, 'DEGF', F12.1, /,
3 '0AVERAGE CYCLIC ROOM TEMPERATURE SWING', T48, 'DEGF', F12.1,
4 /,
5 ' AVERAGE CYCLIC ROOM REL HUM SWING', T51, '%', F12.1, /)
6020 FORMAT ('0*** HEATING ***', /,
1 '0TOTAL BURNER ON TIME (CYCLES)', T50, 'HR', (F10.2, '(',
2 F6.0, ')'), /,
3 '0NET HEATING OUTPUT', T49, 'BTU', (F12.0, 6X), /,
4 ' MIS HEATING OUTPUT', T49, 'BTU', (F12.0, 6X), /,
5 ' TOTAL HEATING OUTPUT', T49, 'BTU', (F12.0, 6X), /,
6 ' TOTAL BURNER FAN ENERGY', T47, 'KW-HR', (F10.2, 8X), /,
7 ' TOTAL BLOWER ENERGY', T47, 'KW-HR', (F10.2, 8X), /,
8 ' TOTAL FUEL INPUT ENERGY', T49, 'BTU', (F12.0, 6X), /,
9 ' TOTAL ENERGY (HEATING)', T49, 'BTU', (F12.0, 6X), /,
A '0HEATING PERFORMANCE FACTOR', 23X, (F12.3, 6X), ///)
6030 FORMAT (' *** COOLING ***', /,
1 '0TOTAL COMPRESSOR ON TIME(CYCLES)', T50, 'HR', F12.2, '(',
2 F6.0, ')', /,
3 '0TOTAL COOLING BY AIR CONDITIONING', T49, 'BTU', F12.0, /,
4 '0TOTAL COMPRESSOR ENERGY', T47, 'KW-HR', F12.2, /,
5 ' TOTAL INDOOR FAN ENERGY', T47, 'KW-HR', F12.2, /,
6 ' TOTAL OUTDOOR FAN ENERGY', T47, 'KW-HR', F12.2, /,
7 ' TOTAL ENERGY (COOLING)', T47, 'KW-HR', F12.2, /,
8 '0COOLING SEASONAL PERFORMANCE FACTOR BTU/WATT-HR', F12.2,
9 /)
6050 FORMAT (1X, F4.3, '/', F4.3, 11F7.0, /)
6060 FORMAT (1X, 15A4, //)
6070 FORMAT (' *** HUMIDIFIER ***', /,
1 '0TOTAL HUMIDIFIER ON TIME', T50, 'HR', F12.2, /,
2 ' TOTAL HUMIDIFIER CYCLES', T52, F12.0, /,
3 ' TOTAL ENTHALPY OF SUPPLY WATER', T49, 'BTU', F12.1, /,
4 ' TOTAL ENTHALPY OF WASTE WATER', T49, 'BTU', F12.1, /,
5 ' TOTAL HEAT REMOVED FROM THE AIR', T49, 'BTU', F12.1, /,
6 ' TOTAL WATER ADDED TO AIR', T50, 'LB', F12.2)
C
END