  1. AS2 SYSTEM INPUT SCREEN FILE - HEAT PUMP COOLING DATA (FILE 'SIHPCDAT.SIS')
  2. 6,"SYSTEMS DATA: HEAT PUMP COOLING FOR SYSTEM:"
  3. 7,"HEAT PUMP COOLING"
  4. 3
  5. 5,1,1,Heat Pump Cooling Capacity (Total Cooling)
  6. 4,1,3,Zonal total cooling capacity method
  7. 4,1,5,(1=Capacities Entered by Zone  2=Autosized)
  8. 4,2,5,(if autosized)  Percent of design total load satisfied,72,%
  9. 2
  10. 5,1,1,Heat Pump Cooling Capacity (Sensible Cooling)
  11. 4,1,3,Zonal sensible cooling capacity method
  12. 4,1,5,(1=Capacities Entered by Zone  2=Autosized)
  13. 4,2,5,(if autosized)  Percent of design sensible load satisfied,72,%
  14. 2
  15. 5,1,1,Cooling Performance
  16. 4,1,3,Design coefficient of performance
  17. 2
  18. 5,1,1,Water Source Heat Pump Only
  19. 4,2,3,Outside temperature at minimum fluid loop temperature,72,°F
  20. 4,2,5,Minimum fluid loop temperature,72,°F
  21. 4,2,3,Outside temperature at maximum fluid loop temperature,72,°F
  22. 4,2,5,Maximum fluid loop temperature,72,°F
  23. 2
  24. 997
  25. 996
  26. 999
  27. 1,9
  28. i  r  c s e  lo  hi h hlp$     d dft$
  29. 1, 5,67,1,3,  1,  2,2,"6.6.10",1,2
  30. 2, 7,67,3,3, 80,300,2,"6.6.10",1,120
  31. 3,10,67,1,3,  1,  2,2,"6.6.10",1,2
  32. 4,12,67,3,3, 80,300,2,"6.6.10",1,120
  33. 5,15,67,4,3,  1, 10,2,"6.6.10",1,3
  34. 6,18,67,3,3,-50,100,2,"6.6.10",1,30
  35. 7,19,67,3,3, 40,100,2,"6.6.10",1,60
  36. 8,20,67,3,3,  0,150,2,"6.6.10",1,80
  37. 9,21,67,3,3, 40,150,2,"6.6.10",1,85
  38.