home *** CD-ROM | disk | FTP | other *** search
/ ftp.msan.hr / ftp.msan.hr.tar / ftp.msan.hr / Drivers / HP / Server / ml150g2supportCD.nrg / Utility / Tools / ml150winasm-2.12.00build811-1.exe / data1.cab / _EB29246FA707404E98A1B54AF2209ECB < prev    next >
Text File  |  2004-07-16  |  5KB  |  105 lines

  1. <!doctype html public "-//w3c//dtd html 4.0 transitional//en">
  2. <html>
  3. <head>
  4. <meta http-equiv="Content-Type" content="text/html; charset=iso-8859-1">
  5.  
  6. <title>Understanding logical-drive verification</title>
  7.  
  8. <base target="_top">
  9. <link rel="stylesheet" href="basicpg.css">
  10. </head>
  11. <body text="#000000" bgcolor="#FFFFFF" link="#0000FF" vlink="#333399" alink="#0000FF">
  12.  
  13. <h1>Understanding logical-drive verification</h1>
  14. <p>The purpose of verifying logical devices is to compute and write the parity
  15.   data on the selected drives. Verifying a logical device confirms that the
  16.   data redundancy for the logical device is correct. </p>
  17. <p><b><img src="images/note.gif" width="15" height="17"> Note:</b>You can also verify a logical device
  18. without writing the parity data. This type of verifiy
  19.   is similar to Verify with fix—it checks the entire drive to ensure that there
  20.   are no problems. However, unlike Verify with fix, Verify does not repair
  21.   inconsistent or bad data. </p>
  22.  
  23.  
  24. <h2>Using automatic verification</h2>
  25. <p>If the logical device is attached to a controller that supports Build initialization,
  26.   the Adaptec Storage Manager automatically verifies all new RAID level-5
  27.   and 50 logical devices. These logical devices must be verified before storing
  28.   data. Verification ensures that the parity data is accurately computed.
  29.   Accurate parity is critical for updating the parity when you begin to store
  30.   data. </p>
  31.  
  32. <p><b><img src="images/note.gif" width="15" height="17"> Note:</b> The Adaptec Storage Manager also the supports Build initialization
  33.   for RAID level-1 and RAID level-10 logical devices. For these RAID levels, the Adaptec Storage Manager automatically copies data from the
  34.   primary drive to the mirror drive. </p>
  35.  
  36.  
  37. <p>During Build initialization, the Adaptec Storage Manager displays <img src="images/buildnew.gif" width="28" height="20">(in
  38.   animation) in the Logical devices view, indicating that the operation is in
  39.   progress. You can perform some actions on the controller during Build initialization,
  40.   such as deleting a logical device; however, you <strong>cannot</strong> perform a
  41.   logical device migration. Also, you can turn off the %SERVER% during Build initialization
  42.   and, when you turn on the %SERVER%, the firmware will continue the build from
  43.   where it left off. </p>
  44.  
  45.  
  46.   <p><b><img src="images/note.gif" width="15" height="17"> Note:</b> You can determine
  47.     if your controller firmware supports Build initialization and background consistency check
  48.     by viewing the controller properties. The properties pane reports if these features
  49.   are enabled or disabled.</p>
  50.  
  51.  
  52. <h2>Using manual verification</h2>
  53. <p>When you create a logical device that is attached to a controller that does
  54.   <b>not</b> support Build initialization, you will receive a warning event in
  55.   the <a href="cusegui5.htm">event viewer</a> stating that you must <b>manually</b>
  56.   verify the logical device before storing data. Use "<a href="asynchld.htm">Verify with fix</a>"
  57.   to manually verify the logical device. You must
  58.   verify <b>new</b> RAID level-5 logical devices after you create them. </p>
  59. <p>Manual verification can be a lengthy operation. You <b>cannot</b> perform
  60.   any other actions on the controller until the manual verification is completed.
  61.   You can verify the logical device immediately or <a href="ctskschd.htm">schedule</a>
  62.   it for a later date and time. You can also schedule the verification as a
  63.   recurring task. A recurring task starts at the initial start
  64.   time, then runs periodically according to the given interval: the same time
  65.   each day, each week, or each month. Do <b>not</b> turn off the %SERVER% until
  66.   the manual verification is complete. </p>
  67.  
  68. <h2>Using manual verification for background consistency check</h2>
  69. <p>Background consistency check is an automatic background verification process. Background consistency check
  70.   keeps data "fresh" by doing the following:</p>
  71. <ul>
  72.   <li>(For RAID level-5 or 50) Reading data and rewriting the data parity.</li>
  73.   <li> (For RAID level-1 or 10) Reading data and rewriting the mirror data.
  74.   </li>
  75. </ul>
  76. <p>If background consistency check is disabled or your controller firmware does not support
  77.   background consistency check, consider manually verifying your logical devices weekly.
  78.   This does not alter data on the drive.</p>
  79. <p><b><img src="images/note.gif" width="15" height="17"> Note:</b> If background consistency check
  80.   is disabled on your controller, you <b>can </b>enable background consistency check, but not
  81.   through the Adaptec Storage Manager. Instead, use the command-line program that
  82. comes on <i>Adaptec RAID Installation</i> CD.
  83.  </p>
  84. <h2>More information</h2>
  85.  
  86. <ul>
  87.   <li><a href="asynchld.htm">Verifying logical devices with fix (action)</a></li>
  88.   <li><a href="averifyld.htm">Verifying logical devices (action)</a></li>
  89.   <li><a href="ctskschd.htm">Understanding scheduled tasks</a></li>
  90.   <li><a href="mtskmain.htm">Using the Task Manager</a></li>
  91. </ul>
  92.  
  93. <div align="center">
  94.   <hr>
  95.   <a href="gportal.htm">Glossary</a> | <a href="menutoc.htm">Contents</a></div>
  96. <p> </p>
  97. <p align="right">x-1062-ASM-00-08-EN </p>
  98.  
  99. </body>
  100.  
  101.  
  102.  
  103.  
  104. </html>
  105.