home *** CD-ROM | disk | FTP | other *** search
/ ftp.msan.hr / ftp.msan.hr.tar / ftp.msan.hr / Drivers / HP / Server / ml150g2supportCD.nrg / Utility / Tools / ml150winasm-2.12.00build811-1.exe / data1.cab / _B8FB79DA211A4DBF80455F4B71D56DF9 < prev    next >
Text File  |  2004-07-16  |  2KB  |  61 lines

  1. <!doctype html public "-//w3c//dtd html 4.0 transitional//en">
  2. <html>
  3. <head>
  4.  
  5. <meta http-equiv="Content-Type" content="text/html; charset=iso-8859-1">
  6.  
  7.  <title>Manually rebuilding a failed drive</title>
  8.  
  9. <base target="_top">
  10. <link rel="stylesheet" href="basicpg.css">
  11. </head>
  12. <body text="#000000" bgcolor="#FFFFFF" link="#0000FF" vlink="#333399" alink="#0000FF">
  13.  
  14.  <h1><img src="images/l_pderr.gif" alt="failed physical drive" width="37" height="27" align="absmiddle">
  15.   Manually rebuilding a failed drive</h1>
  16. <p> Use this action to rebuild a <a href="gcrt.htm">degraded</a> logical device
  17.   when a physical drive in the disk group is <a href="gddd.htm">failed</a>.
  18.  
  19.   Normally,
  20.     the controller rebuilds a logical device when it detects the removal
  21.     and reinsertion of a drive that is part of a disk group. Use this operation to force
  22.     the rebuild to begin immediately, without physically removing and replacing
  23.   the disk drive.
  24.  
  25.  
  26.   </p>
  27. <p><img src="images/note.gif" width="15" height="17"><strong> Note:</strong> The
  28.   controllers can rebuild RAID level-1, level-5,
  29.   level-10, and level-50 logical devices. They cannot, however,
  30.   rebuild RAID level-0 logical devices because RAID level-0 is not redundant.</p>
  31. <p>Complete the following steps to manually rebuild a failed drive:</p>
  32. <ol>
  33.   <li>In the <a href="cusegui4.htm">Physical devices view</a>, click <img src="images/s_pd_ddd.gif" alt="failed physical drive" width="22" height="15" align="absbottom">
  34.     (failed physical drive).<br>
  35.     <br>
  36.   </li>
  37.   <li> Right-click <b>Rebuild drive</b>.<br>
  38.     <br>
  39.   </li>
  40.   <li>Click <b>Yes</b><strong> </strong>to confirm. <br>
  41.     <br>
  42.     <img src="images/note.gif" width="15" height="17"><strong> Note:</strong>
  43.     During the rebuild operation, the failed drive enters the rebuild state and
  44.     the logical device remains degraded until the rebuild operation is completed.<br>
  45.   </li>
  46. </ol>
  47. <h2>More information</h2>
  48.  
  49. <ul>
  50.   <li><a href="cfixddd.htm">Rebuilding a failed drive (concepts)</a></li>
  51. </ul>
  52.  
  53. <div align="center">
  54.   <hr>
  55.   <a href="gportal.htm">Glossary</a> | <a href="menutoc.htm">Contents</a></div>
  56. <p> </p>
  57. <p align="right">x-0371-ASM-00-08-EN </p>
  58.  
  59. </body>
  60. </html>
  61.