  1. <!doctype html public "-//w3c//dtd html 4.0 transitional//en">
  2. <html>
  3. <head>
  4.  
  5.  
  6.  
  7.  
  8.  
  9.  
  10. <meta http-equiv="Content-Type" content="text/html; charset=iso-8859-1">
  11.  
  12. <title>Understanding when RAID level-x0 logical devices change to the degraded state</title>
  13.  
  14. <base target="_top">
  15. <link rel="stylesheet" href="basicpg.css">
  16. </head>
  17. <body text="#000000" bgcolor="#FFFFFF" link="#0000FF" vlink="#333399" alink="#0000FF">
  18.  
  19. <h1>Understanding when RAID level-x0 logical devices change state</h1>
  20. <p>Start with four physical drives.</p>
  21. <p>Use two physical drives to create disk group A and two physical drives to create
  22.   disk group B.</p>
  23. <p>Use arrays A and B to create spanned disk group 1. As part of a spanned disk group, disk groups
  24.   A and B are now called "subarrays."</p>
  25. <p>A sub-logical device is created in disk group A and another sub-logical device is
  26.   created in disk group B.</p>
  27. <p>Then, create a logical device in spanned disk group 1.</p>
  28. <p>If the sub-logical device in subarray A is in the optimal state and the sub-logical device in subarray B is in the optimal state, then the logical device in spanned
  29.   disk group 1 is in the optimal state.</p>
  30. <p>If a physical drive fails in subarray A, then the sub-logical device in subarray
  31.   A changes to the degraded state. Subarray B is still in the optimal state. The
  32.   logical device in spanned disk group 1 changes to the degraded state.</p>
  33. <p>If the second physical drive fails in subarray A, then the sub-logical device
  34.   in subarray A changes to the failed state. Subarray B remains in the optimal state.
  35.   The logical device in spanned disk group 1 changes to the failed state.</p>
  36. <p>If the sub-logical device in subarray A is in the degraded state and a physical
  37.   drive fails in subarray B, then the sub-logical device in subarray B changes
  38.   to the degraded state. With both sub-logical devices in the degraded state, the
  39.   logical device in spanned disk group 1 remains in the degraded state.</p>
  40. <h2>More information</h2>
  41. <ul>
  42.   <li><a href="ccrespar.htm">Understanding creating spanned disk groups</a></li>
  43.   <li><a href="wcrespar.htm">Creating spanned disk groups in the wizard</a></li>
  44.   <li><a href="craidx0.htm">Understanding RAID level-x0</a></li>
  45.   <li><a href="cusable.htm">Physical drive capacity and unusable capacity</a></li>
  46.   <li><a href="ccrearry.htm">Understanding creating basic disk groups</a></li>
  47. </ul>
  48.  
  49. <div align="center">
  50.   <hr>
  51.   <a href="gportal.htm">Glossary</a> | <a href="menutoc.htm">Contents</a></div>
  52. <p> </p>
  53. <p align="right">x-1020-ASM-00-09-EN </p>
  54.  
  55. </body>
  56.  
  57.  
  58.  
  59.  
  60. </html>
  61.