  1. <!doctype html public "-//w3c//dtd html 4.0 transitional//en">
  2. <html>
  3. <head>
  4. <meta http-equiv="Content-Type" content="text/html; charset=iso-8859-1">
  5. <title>Message background and recovery options</title>
  6. <base target="_top">
  7. <link rel="stylesheet" href="basicpg.css">
  8. </head>
  9. <body text="#000000" bgcolor="#FFFFFF" link="#0000FF" vlink="#333399" alink="#0000FF">
  10. <h1>Set drive to failed: controller [number], <<em>device location</em>></h1>
  11. <h2>Explanation:</h2>
  12. <ul>
  13.   <li>There was an error in communication between the physical drive and the controller.</li>
  14.   <li>The controller failed.</li>
  15. </ul>
  16.  
  17. <h2>Action:</h2>
  18.  
  19. <ol>
  20.   <li>Verify that there is power to external enclosures and connections. </li>
  21.   <li>Verify that cables are properly seated.</li>
  22.   <li>Check for damaged, bent, or pushed pins on the following:
  23.     <ul>
  24.       <li>Termination (for non-backplane systems)</li>
  25.       <li>Backplanes</li>
  26.       <li>Physical drives</li>
  27.       <li>Controller</li>
  28.     </ul>
  29.   </li>
  30. </ol>
  31. <p>If you cannot identify a connection problem, the replacement order for parts
  32.   is the following:
  33. <ol>
  34.   <li>Termination (for non-backplane systems)</li>
  35.   <li> Cables</li>
  36.   <li>Physical drives</li>
  37.   <li>Backplanes</li>
  38.   <li>Controller</li>
  39. </ol>
  40. <p>Before replacing a physical drive or controller, verify that it is updated
  41.   with the latest firmware (microcode) and that they still fail. <br>
  42.   <br>
  43.   <b><img src="images/note.gif" width="15" height="17"> Note:</b> If multiple
  44.   physical drives are marked failed within the same time period, check the cables
  45.   and backplanes.
  46.  
  47. <div align="center">
  48.   <hr>
  49.   <a href="gportal.htm">Glossary</a> | <a href="menutoc.htm">Contents</a></div>
  50. <p> </p>
  51. <p align="right">x-0192-ASM-00-06-EN </p>
  52.  
  53. </body>
  54. </html>