  1. <!DOCTYPE HTML PUBLIC "-//W3C//DTD HTML 4.0 Transitional//EN">
  2.  <HTML><HEAD><TITLE>Rebuilding a failed drive</TITLE>
  3. <META http-equiv=Content-Type content="text/html; charset=iso-8859-1"><BASE
  4. target=_top><LINK href="basicpg.css" rel=stylesheet>
  5. <META content="MSHTML 6.00.2600.0" name=GENERATOR></HEAD>
  6. <BODY text=#000000 vLink=#333399 aLink=#0000ff link=#0000ff bgColor=#ffffff>
  7. <H1>Rebuilding a failed drive</H1>
  8. <P>A physical drive is marked failed when there is a loss of communication
  9. between the controller and the physical drive. This can be caused by any of the
  10. following: </P>
  11. <UL>
  12.   <LI>An improperly connected cable, physical drive, or controller<BR><BR>
  13.   <LI>Loss of power to a drive <BR><BR>
  14.   <LI>An improperly assembled SCSI channel in an unsupported configuration
  15.   <BR><BR>
  16.   <LI>A defective cable, backplane, physical drive, or controller <BR><BR>
  17.   <LI>Connecting unsupported SCSI devices (such as tape drives or CD-ROM drives)
  18.   to the same SCSI channel used for a disk group </LI></UL>
  19. <P>In each case, after the communication problem is resolved, a rebuild
  20. operation is required to reconstruct the data for the device in its disk disk group.
  21. The controllers can reconstruct RAID level-1, level-5,
  22. level-10, and level-50 logical devices. They
  23. cannot, however, reconstruct data stored in RAID level-0 logical devices because
  24. RAID level-0 is not redundant. If a disk group contains only RAID level-0 logical
  25. drives, the logical devices in the disk group are marked failed and the logical devices contain damaged data. You cannot rebuild the logical devices. You must
  26. correct the cause of the failure or replace the physical drives; then, you must
  27. restore your data.
  28. <P>To prevent data-integrity problems, the controllers set the RAID
  29. level-0 logical devices in the affected disk group to blocked during the rebuild
  30. operation for RAID level-1 or RAID level-5. After the rebuild operation is
  31. completed, you can unblock the RAID level-0 logical devices and access them once
  32. again. Remember, however, that the RAID level-0 logical devices contain damaged
  33. data.
  34. <H2>More information</H2>
  35. <UL>
  36.   <LI><A href="cfixddd1.htm">Recovering from failed drives</A>
  37.   <li><a href="cfixddd2.htm">Rebuilding a hot-swap drive</a></li>
  38.   <LI><A href="arbddd.htm">Manually rebuilding a failed drive</A>
  39.   <LI><A href="achangrr.htm">Changing the rebuild rate (action)</A>
  40.   <LI><A href="aunblock.htm">Unblocking a logical device (action)</A>
  41.   <LI><A href="craid0.htm">RAID level-0</A>
  42.   <LI><A href="craid1.htm">RAID level-1</A>
  43.   <LI><A href="craid5.htm">RAID level-5</A>
  44.   <LI><A href="craidx0.htm">RAID level-x0</A> </LI></UL>
  45. <DIV align=center>
  46. <HR>
  47. <A href="gportal.htm">Glossary</A> | <A href="menutoc.htm">Contents</A></DIV>
  48. <P> </P>
  49. <P align=right>x-1025-ASM-00-05-EN </P></BODY></HTML>