home *** CD-ROM | disk | FTP | other *** search
/ ftp.msan.hr / ftp.msan.hr.tar / ftp.msan.hr / Drivers / HP / Server / ml150g2supportCD.nrg / Utility / Tools / ml150winasm-2.12.00build811-1.exe / data1.cab / _29E01C7C490C4D37962ECA9832133276 < prev    next >
Text File  |  2004-07-16  |  4KB  |  104 lines

  1. <!doctype html public "-//w3c//dtd html 4.0 transitional//en">
  2. <html>
  3. <head>
  4.  
  5.  
  6.  
  7.  
  8.  
  9.  
  10. <meta http-equiv="Content-Type" content="text/html; charset=iso-8859-1">
  11.  
  12.  <title>Recovering from failed drives</title>
  13.  
  14. <base target="_top">
  15. <link rel="stylesheet" href="basicpg.css">
  16. </head>
  17. <body text="#000000" bgcolor="#FFFFFF" link="#0000FF" vlink="#333399" alink="#0000FF">
  18.  
  19. <h1>Recovering from failed drives</h1>
  20. <p>If the failed drives are not part of a disk group, contact your service representative.
  21. </p>
  22. <p>If a physical drive fails in a disk group or multiple physical drives fail in separate
  23.   disk groups (one physical drive per array), complete the following steps:
  24. <ol type=1>
  25.   <li>Replace each failed physical drive. The controller starts the
  26.     rebuild operation when it detects the removal and reinsertion of a drive that
  27.     is part of a disk group.<br>
  28.     <br>
  29.     <img src="images/note.gif" width="15" height="17"><b> Note:</b> (For a configuration
  30.     that contains a hot-spare drive) If you replace a failed physical drive, it
  31.     is not necessary to position the new physical drive on the same SCSI channel
  32.     and SCSI ID as the original hot-spare drive. The replacement physical drive
  33.     is automatically incorporated into the configuration as a hot-spare drive.
  34.     Here is an example of how this works: <br>
  35.     <br>
  36.     <ol>
  37.       <li>The original configuration consists of a RAID level-5 logical device
  38.         composed of four physical drives. The physical drives are connected to
  39.         SCSI channel 1; they are assigned SCSI IDs 0, 1, 2, and 3. SCSI ID 3 is
  40.         a hot-spare drive. <br>
  41.         <br>
  42.       </li>
  43.       <li>The physical drive at Channel 1, SCSI ID 2, fails; the logical device
  44.         enters the degraded state. <br>
  45.         <br>
  46.       </li>
  47.       <li>The hot-spare drive at Channel 1, SCSI ID 3, is rebuilt into the disk group.
  48.         <br>
  49.         <br>
  50.       </li>
  51.       <li>You remove the failed physical drive at Channel 1, SCSI ID 2, and replace
  52.         it with a new physical drive. The new physical drive at Channel 1, SCSI
  53.         ID 2, is automatically assigned to be a hot-spare drive. <br>
  54.         <br>
  55.       </li>
  56.     </ol>
  57.   </li>
  58.   <li>If a rebuild operation is in progress, wait until the rebuild is complete.
  59.     Otherwise, go to step 3.<br>
  60.     <br>
  61.     <img src="images/note.gif" width="15" height="17"><b> Note:</b> If you are
  62.     replacing multiple failed drives, you must wait for each rebuild operation
  63.     to complete before starting subsequent rebuild operations. <br>
  64.     <br>
  65.   </li>
  66.   <li>Verify the cables, physical drives, and controllers are installed properly.
  67.     <br>
  68.     <br>
  69.   </li>
  70.   <li>Attempt to rebuild the failed physical drive by <a href="cfixddd2.htm">performing
  71.     a hot-swap rebuild</a>. <br>
  72.     <br>
  73.   </li>
  74.   <li>If the hot-swap rebuild fails, contact your service representative.
  75.   </li>
  76. </ol>
  77. <p>
  78. <h2>More information</h2>
  79.  
  80. <ul>
  81.   <li><a href="cfixddd.htm">Rebuilding a failed drive</a></li>
  82.   <li><a href="cfixddd2.htm">Rebuilding a hot-swap drive</a></li>
  83.   <li><a href="arbddd.htm">Manually rebuilding a failed drive</a></li>
  84.   <li><a href="achangrr.htm">Changing the rebuild rate (action)</a></li>
  85.   <li><a href="aunblock.htm">Unblocking a logical device (action)</a></li>
  86.   <li><a href="craid0.htm">RAID level-0</a></li>
  87.   <li><a href="craid1.htm">RAID level-1</a></li>
  88.   <li><a href="craid5.htm">RAID level-5</a></li>
  89. </ul>
  90.  
  91. <div align="center">
  92.   <hr>
  93.   <a href="gportal.htm">Glossary</a> | <a href="menutoc.htm">Contents</a></div>
  94.  
  95. <p> </p>
  96. <p align="right">x-1026-ASM-00-05-EN </p>
  97.  
  98. </body>
  99.  
  100.  
  101.  
  102.  
  103. </html>
  104.