home *** CD-ROM | disk | FTP | other *** search
/ Win 3.11 Apps / win311aps.iso / DOS622 / NETWORKS.TXT < prev    next >
Text File  |  1995-05-15  |  20KB  |  547 lines

  1.  
  2. NETWORKS.TXT
  3.  
  4. This file contains information about making your network compatible
  5. with MS-DOS 6.22. If you are running MS-DOS 5.0 or later, you do not 
  6. need to make any changes to your network to make it compatible with 
  7. MS-DOS 6.22. 
  8.  
  9. If Setup referred you to this file, see Section 1 below. If you are
  10. looking for additional information about your network software, find
  11. the appropriate section below.
  12.  
  13. This file contains the following sections:
  14.  
  15. 1.  Setup referred you to the NETWORKS.TXT file
  16. 2.  3+Share
  17. 3.  Arcnet systems
  18. 4.  Artisoft LANtastic
  19. 5.  AT&T StarGroup (non-LAN Manager) 
  20. 6.  Banyan VINES
  21. 7.  DEC Pathworks and PCSA
  22. 8.  IBM PC LAN
  23. 9.  IBM DOS LAN Requester Version 1.30 or Earlier
  24. 10. Microsoft LAN Manager and 100-Percent Compatible
  25.     Networks
  26. 11. Microsoft MS-Net and 100-Percent Compatible
  27.     Networks
  28. 12. Net/One PC  
  29. 13. Novell Networks
  30. 14. PC-NFS
  31. 15. TCS 10Net or DCA 10Net
  32.  
  33. 1.  Setup referred you to the NETWORKS.TXT file
  34. ===============================================
  35. If Setup displayed the "You have specified that your computer is
  36. connected to a network" screen, your computer might be running an
  37. older version of network software that is incompatible with MS-DOS
  38. 6.22. For more information, see the section in this file that
  39. addresses your network software. If you don't find instructions on
  40. making your network compatible with MS-DOS 6.22, obtain an upgrade of
  41. your network software from your network vendor, install the upgraded
  42. network files, and then run MS-DOS 6.22 Setup again. 
  43.  
  44. After you have upgraded your network software, when Setup displays 
  45. the "You have specified that your computer is connected to a network"
  46. screen, choose the Continue option. Your network should work correctly
  47. with MS-DOS 6.22.
  48.  
  49. 2. 3+Share
  50. ==========
  51. If your network software is 3+Share 1.6 or earlier, and you
  52. previously upgaded to MS-DOS 5.0, your current version of the 3+Share
  53. redirector will work with MS-DOS 6.22. After you install MS-DOS 6.22,
  54. type the following at the command prompt, and restart your computer:
  55.  
  56.    SETVER MSREDIR.EXE 5.0
  57.  
  58. If you do not have the redirector included with MS-DOS 5.0,
  59. obtain the redirector by ordering the Supplemental disks or by
  60. downloading the disks from the Microsoft Product Support Download
  61. Service (MSDL). For more information, see the coupon at the back of
  62. the MICROSOFT MS-DOS USER'S GUIDE.
  63.  
  64. After you obtain the redirector, follow the instructions in the
  65. NET.TXT file on the Supplemental disks.
  66.  
  67. 3. Arcnet systems
  68. =================
  69. If your network uses Arcnet hardware, you might need to run the
  70. Microsoft Diagnostics (MSD) program by using the MSD /I command.
  71. If you must use the /I switch, do not choose the Networks option 
  72. in MSD.
  73.  
  74. 4. Artisoft LANtastic
  75. =====================
  76. If you are using any version of Artisoft LANtastic, 
  77. shut down the LANtastic server before you run MS-DOS 6.22
  78. Setup. There is no need to shut down the redirector.
  79.  
  80. Artisoft LANtastic versions 3.02 and higher are compatible 
  81. with MS-DOS 6.22.
  82.  
  83. If you are using a LANtastic version earlier than 2.5,
  84. contact your network vendor for an update.
  85.  
  86. If you are using LANtastic versions 2.5 through 3.01,
  87. carry out the following procedure
  88.  
  89. To update LANtastic versions 2.5 through 3.01:
  90.  
  91. 1. Shut down the LANtastic server. You can leave the
  92.    redirector running.
  93.  
  94. 2. Set up MS-DOS 6.22 on your computer. For more information
  95.    about installing MS-DOS 6.22, see the chapter 
  96.    "Getting Started" in the MICROSOFT MS-DOS USER'S GUIDE.
  97.  
  98.    If MS-DOS displays an "Incorrect DOS version" message
  99.    when your network restarts, ignore it.
  100.  
  101. 3. Type the following command at the command prompt:
  102.  
  103.    SETVER SERVER.EXE 4.00
  104.  
  105. 4. Restart your computer.
  106.  
  107. If you are using EMM386, you might need to exclude the memory area
  108. used by the network adapter card. To do this, use the X switch with
  109. the DEVICE command for EMM386.EXE in your CONFIG.SYS file. If you are
  110. using the factory-set defaults for the LANtastic 2Mbps adapter,
  111. include the X=D800-DFFF switch with the DEVICE command for
  112. EMM386.EXE. If this memory region is not excluded, you might
  113. experience problems with programs that use expanded memory.
  114.  
  115. NOTE  Microsoft Defragmenter is incompatible with LANtastic network
  116. software if the server service is loaded. If only the redirector is
  117. loaded, Microsoft Defragmenter is compatible with LANtastic network
  118. software.
  119.  
  120. 5. AT&T StarGroup (non-LAN Manager) 
  121. ===================================
  122. If your network software is AT&T StarGroup, run MS-DOS 6.22 Setup.
  123. When Setup displays the "You have specified that your computer 
  124. is connected to a network" screen, choose Continue, and follow 
  125. the instructions on your screen. If you cannot run your network 
  126. software after running Setup, carry out the following procedure:
  127.  
  128. 1. Type the following commands at the command prompt:
  129.  
  130.    SETVER SETUP.EXE 4.00
  131.    SETVER ATTSTART.EXE 4.00
  132.  
  133. 2. Restart your computer.
  134.  
  135. 3. Use your StarGroup installation disks to remove the
  136.    existing network software from your computer.
  137.  
  138. 4. Reinstall StarGroup. When the StarGroup installation
  139.    prompts you to indicate which version of MS-DOS you are
  140.    using, choose MS-DOS version 4.0.
  141.  
  142. 6. Banyan VINES 
  143. ===============
  144. Banyan VINES versions 4.1 and higher are compatible with MS-DOS 
  145. 6.22. You can use Banyan VINES version 4.0x with MS-DOS 6.22 if you
  146. have the REDIRALL.EXE or REDIR4.EXE file in the BANYAN
  147. directory on your hard disk.
  148.  
  149. If neither file is on your hard disk, but you have the VINES
  150. installation disks that include one of these files, copy
  151. the file to the directory on your hard disk that contains
  152. your network files.
  153.  
  154. If the files are not on your hard disk or on the VINES
  155. installation disks, contact your network vendor.
  156.  
  157. If you have a VINES version earlier than 4.0, contact your
  158. network vendor for an update.
  159.  
  160. NOTE
  161. In some cases, Banyan VINES is incompatible with MemMaker. For
  162. example, if your network software loads multiple components
  163. into different UMB regions, MemMaker may not work correctly on
  164. your computer.
  165.  
  166. 7. DEC Pathworks and PCSA
  167. =========================
  168. If you have DEC PATHWORKS for DOS version 4.1,
  169. carry out the following procedure:
  170.  
  171. 1. If you are upgrading from MS-DOS version 3.3 or earlier,
  172.    update your redirector file, REDIR.EXE. Obtain
  173.    REDIR.400 from the PATHWORKS disks or system service,
  174.    rename it to REDIR.EXE, and place it in your DECNET
  175.    directory.
  176.  
  177. 2. Install MS-DOS 6.22 on your computer. For more information about 
  178.    installing MS-DOS 6.22, see the chapter "Getting Started" in
  179.    the MS-DOS USER'S GUIDE.
  180.  
  181. Version 4.0 of PATHWORKS for DOS is compatible with MS-DOS
  182. 6.22. However, you must carry out the following procedure to 
  183. achieve this compatibility.
  184.  
  185. To update PATHWORKS version 4.0:
  186.  
  187. 1. If you are upgrading from MS-DOS version 3.3 or earlier,
  188.    update your redirector file, REDIR.EXE. Obtain REDIR.400 
  189.    from the PATHWORKS disks or system service, rename it to 
  190.    REDIR.EXE, and place it in your DECNET directory.
  191.  
  192. 2. Install MS-DOS 6.22 on your computer. For more information about 
  193.    installing MS-DOS 6.22, see the chapter "Getting Started"
  194.    in the MS-DOS USER'S GUIDE.
  195.  
  196. 3. Restart your computer, but do not yet run STARTNET.BAT,
  197.    which starts the network.
  198.  
  199. 4. Type each of the following lines at the command prompt:
  200.  
  201.    SETVER USE.EXE 4.00
  202.  
  203.    SETVER MEMMAN.EXE 4.00
  204.  
  205.    SETVER LAD.EXE 4.00
  206.  
  207.    SETVER SHOW.EXE 4.00
  208.  
  209.    SETVER NETSETUP.EXE 4.00
  210.  
  211. 5. Restart your computer, and run STARTNET.BAT.
  212.  
  213. NOTE  If you upgrade to PATHWORKS 4.1 from PATHWORKS 4.0, you must
  214. disable the SETVER commands you typed in this procedure. To do this
  215. after you install PATHWORKS 4.1, type the same commands, but replace
  216. the 4.00 with /D in each command.
  217.  
  218. If you are using a version of PATHWORKS or PCSA earlier than 4.0,
  219. contact your network vendor for an update. Meanwhile, if you are
  220. using PATHWORKS or PCSA version 3.x, you can start using MS-DOS 6.22
  221. by carrying out the following procedure.
  222.  
  223. NOTE  To get support for MS-DOS Task Swapper, use PATHWORKS for DOS
  224. version 4.1 or later.
  225.  
  226. To temporarily update PATHWORKS or PCSA version 3.x:
  227.  
  228. 1. If you are upgrading from MS-DOS version 3.3 or earlier,
  229.    update your redirector file, REDIR.EXE. Obtain REDIR.400 
  230.    from the PATHWORKS disks or system service, rename it to 
  231.    REDIR.EXE, and place it in your DECNET directory.
  232.  
  233. 2. Install MS-DOS 6.22 on your computer. For more information about 
  234.    installing MS-DOS 6.22, see the chapter "Getting Started" in the 
  235.    MICROSOFT MS-DOS USER'S GUIDE. If MS-DOS displays a series of 
  236.    "Incorrect DOS version" messages when your network restarts,
  237.    ignore these.
  238.  
  239. 3. Type all of the following commands at the command
  240.    prompt:
  241.  
  242.    SETVER USE.EXE 4.00
  243.    SETVER EMSLOAD.EXE 4.00
  244.    SETVER SCH.EXE 4.00
  245.    SETVER NETSETUP.EXE 4.00
  246.    SETVER NCP.EXE 4.00
  247.    SETVER DNNETHAT.EXE 4.00
  248.    SETVER LAD.EXE 4.00
  249.    SETVER DLL.EXE 4.00
  250.    SETVER MEMMAN.EXE 4.00
  251.    SETVER DNNETHLD.EXE 4.00
  252.    SETVER SHOW.EXE 4.00
  253.  
  254. 4. Restart your computer.
  255.  
  256. 8. IBM PC LAN
  257. ==============
  258. If you use IBM PC LAN 1.34 and have problems with
  259. applications that use record locking or file locking, you
  260. may need an updated REDIR50.EXE file included in ICO 3039.
  261. Contact IBM Support Channel.
  262.  
  263. IBM PC LAN Program Version 1.33 or Earlier
  264. ------------------------------------------
  265. To use MS-DOS 6.22 with IBM PC LAN Program (PCLP), you need
  266. one of the following:
  267.  
  268. o IBM PCLP version 1.34 installed.
  269.  
  270. o IBM PCLP version 1.3x that has been updated to version
  271.   1.34 by applying the appropriate IBM Corrective Service 
  272.   Disks. Contact IBM Product Support to obtain the software 
  273.   you need.
  274.  
  275. If you are running a PCLP version earlier than 1.30, contact
  276. IBM for the necessary software and instructions.
  277.  
  278. To update IBM PCLP versions 1.30 through 1.34:
  279.  
  280. 1. Skip to step 3 if you are upgrading from version 1.34.
  281.    Otherwise, install the necessary IBM PCLP software by 
  282.    following the instructions included with the Corrective 
  283.    Service Disk(s) you received from IBM.
  284.  
  285. 2. Restart your computer, and make sure the network starts.
  286.  
  287.    If the network doesn't start, quit this procedure and
  288.    contact IBM for help.
  289.  
  290. 3. Set up MS-DOS 6.22 on your computer. For more information
  291.    about installing MS-DOS 6.22, see the chapter "Getting 
  292.    Started" in the MICROSOFT MS-DOS USER'S GUIDE.
  293.  
  294.    When Setup restarts your computer, the following message 
  295.    appears on your screen:
  296.  
  297.    Start PC LAN Program 1.3 (Y/N)?
  298.  
  299. 4. Type N, and press ENTER.
  300.  
  301. 5. Type the following at the command prompt:
  302.  
  303.    SETVER NET.COM /D
  304.  
  305. 6. Restart your computer.
  306.  
  307.    The following message appears on your screen:
  308.  
  309.    Start PC LAN Program 1.3 (Y/N)?
  310.  
  311. 7. Type Y, and press ENTER.
  312.  
  313.    NOTE  If, after setting up MS-DOS, your CONFIG.SYS file
  314.    contains a command for loading the IFSFUNC.EXE file, disable it 
  315.    by typing REM and a space in front of the command. Then save 
  316.    the file and restart your computer.
  317.  
  318.    NOTE  Microsoft Defragmenter program will not run on a PCLP
  319.    server.
  320.  
  321. 9. IBM DOS LAN Requester Version 1.30 or Earlier
  322. =================================================
  323. To use MS-DOS 6.22 with IBM DOS LAN Requester, you need one
  324. of the following:
  325.  
  326. o DOS LAN Requester files that are included with OS/2 LAN
  327.   Server version 1.30.1.
  328.  
  329. o DOS LAN Requester files that come with OS/2 LAN Server
  330.   version 1.30, which has had IBM Corrective Service
  331.   Diskette (CSD) 5015 applied to it.  Contact IBM Product
  332.   Support to obtain the software you need.
  333.  
  334. If you are running a DOS LAN Requester version earlier than
  335. 1.30, contact IBM for the necessary software and
  336. instructions.
  337.  
  338. To update IBM DOS LAN Requester version 1.30:
  339.  
  340. 1. Upgrade your DOS LAN Requester software to version
  341.    1.30.1 by following the instructions included with IBM
  342.    Corrective Service Disk 5015.
  343.  
  344. 2. Restart your computer, and make sure the network starts.
  345.  
  346.    If the network doesn't start, quit this procedure and
  347.    contact IBM for help.
  348.  
  349. 3. Set up MS-DOS 6.22 on your computer. For more information
  350.    about installing MS-DOS 6.22, see the chapter "Getting 
  351.    Started" in the MICROSOFT MS-DOS USER'S GUIDE.
  352.  
  353.    When Setup restarts your computer, the following
  354.    message appears on your screen:
  355.  
  356.    Start DOS LAN Requester (Y/N)?
  357.  
  358. 4. Type N, and press ENTER.
  359.  
  360. 5. Type the following at the command prompt:
  361.  
  362.    SETVER NET.COM /D
  363.  
  364. 6. Restart your computer.
  365.  
  366.    The following message appears on your screen:
  367.  
  368.    Start DOS LAN Requester (Y/N)?
  369.  
  370. 7. Type Y, and press ENTER.
  371.  
  372.    NOTE  If, after setting up MS-DOS, your CONFIG.SYS file
  373.    has a command for loading the IFSFUNC.EXE file,
  374.    disable it by typing REM and a space in front
  375.    of the command. Then save the file and restart
  376.    your computer.
  377.  
  378. 10. Microsoft LAN Manager and 100-Percent Compatible Networks
  379. =============================================================
  380. If you are running any version of Microsoft LAN Manager or a
  381. 100-Percent Compatible network, and Setup referred you to this file,
  382. obtain updated network files by ordering the Supplemental disks or by
  383. downloading the disks from the Microsoft Product Support Download
  384. Service (MSDL). For more information, see the coupon at the back of
  385. the MICROSOFT MS-DOS USER'S GUIDE.
  386.  
  387. After you obtain the Supplemental disks, follow the instructions
  388. in the NET.TXT file on the Supplemental disks.
  389.  
  390. 11. Microsoft MS-Net and 100-Percent Compatible Networks
  391. ========================================================
  392. If you are running any version of Microsoft MS-Net or a 100-Percent
  393. Compatible network, and Setup referred you to this file, obtain
  394. updated network files by ordering the Supplemental disks or by
  395. downloading the disks from the Microsoft Product Support Download
  396. Service (MSDL). For more information, see the coupon at the back of
  397. the MICROSOFT MS-DOS USER'S GUIDE.
  398.  
  399. After you obtain the Supplemental disks, follow the instructions
  400. in the NET.TXT file on the Supplemental disks.
  401.  
  402. 12. Net/One PC
  403. ==============
  404. If Ungermann-Bass Net/One PC does not load with MS-DOS 6.22,
  405. do one of the following:
  406.                               
  407. o Contact your network vendor to get an updated LOADNIU.EXE file.
  408.  
  409. o Put a UBPAUSE command between the LOADNIU and XNSBIOS
  410.   lines in your MSNET.INI file.
  411.  
  412. o Run network commands from a batch file that includes a
  413.   PAUSE command between the LOADNIU and XNSBIOS lines.
  414.      
  415. 13. Novell Networks
  416. ===================
  417. When this NETWORKS.TXT file was published, the current version of the
  418. workstation shell was 3.32 PTF. Obtain version 3.32 PTF or later for 
  419. use with MS-DOS 6.22.
  420.  
  421. If you have a NetWare version earlier than 2.1, or your network
  422. software uses any of the following files, contact your network
  423. vendor:
  424.  
  425. NET3.COM
  426. NET4.COM
  427. XMSNET3.EXE
  428. XMSNET4.EXE
  429. EMSNET3.EXE
  430. EMSNET4.EXE
  431.  
  432. If you can't load MS-DOS 6.22 on your remote-boot workstation,
  433. contact Novell for the RPLFIX.COM file.
  434.  
  435. If you run LOGIN.EXE, MAP.EXE, and SESSION.EXE from MS-DOS
  436. Shell or while MS-DOS Shell is running, a search path is not
  437. added to the existing path. Use these programs before starting
  438. MS-DOS Shell.
  439.  
  440. If you use the Novell login program to set the COMSPEC variable after
  441. starting MS-DOS 6.22, and you can't reload the COMMAND.COM file, edit
  442. the SHELL command line in your CONFIG.SYS file. Make sure the path to
  443. COMMAND.COM points to the root directory and remove the C:\DOS\
  444. parameter that follows the path, if one exists.
  445.  
  446. For example, suppose your SHELL command line looks like
  447. this:
  448.  
  449.     SHELL=C:\DOS\COMMAND.COM  C:\DOS\  /P  /E:512
  450.  
  451. Change it to look like this:
  452.  
  453.     SHELL=C:\COMMAND.COM  /P  /E:512
  454.  
  455. Or contact your Novell vendor to get a new login program.
  456.  
  457. If you are having problems using Microsoft Undelete on a Novell
  458. network, use the MAP ROOT command in conjunction with the Delete
  459. Sentry level of delete protection. (If you have Novell Netware
  460. version 2.15c or older, obtain the most recent MAP.EXE file from your
  461. network vendor.) For example, you would use MAP ROOT syntax similar
  462. to the following (normally specified in the server's login script):
  463.  
  464. MAP ROOT F:=COUNT/SYS:USERS/JOEB
  465.  
  466. In this example, F is the network drive letter, COUNT is a file 
  467. server name, SYS is the volume name, USERS is a subdirectory of 
  468. volume SYS, and JOEB is the root for a network user. On JOEB's 
  469. computer, the AUTOEXEC.BAT file would contain the following syntax:
  470.  
  471. UNDELETE /SF
  472.  
  473. The /S switch specifies the Delete Sentry level of delete protection and 
  474. F specifies a network drive to be protected. The AUTOEXEC.BAT file should
  475. specify /S[drive] for each drive to be protected.
  476.  
  477. NOTE
  478. If you use Microsoft Backup for MS-DOS or Windows to back up files 
  479. to a network, and your network software is NetWare 286, the gas gauge 
  480. will move very slowly at first. This is due to the way NetWare 286 
  481. handles writing files to the network.
  482.  
  483. NOTE
  484. The %OS_VERSION parameter used in login scripts will return v6.22 
  485. as long as you are using shell version 3.32 PTF from Novell. 
  486. You should not need a SETVER entry for the Novell shell.
  487.  
  488. MS-DOS Setup and Shared Windows Configuration
  489. ---------------------------------------------
  490. If you use a search drive to access your Windows initialization files
  491. (PROGMAN.INI, SYSTEM.INI, and WINFILE.INI) on a network directory, and
  492. you want to install the Windows programs included with MS-DOS 6.22,
  493. carry out the following procedure before you run Setup.
  494.  
  495. NOTE The information in this section applies both to the normal 
  496. Setup installation program and Setup run with the /E switch.
  497.  
  498. * Temporarily override the search drive by using the MAP command
  499.   at the command prompt. For example, if the network drive assignment
  500.   for your Windows directory is W, and the path is \USER\JOEB,
  501.   type MAP DEL W: at the command prompt to temporarily delete the
  502.   search drive. Then type MAP W:=SYS:USER\JOEB at the command prompt. 
  503.   Then run Setup. After Setup is finished and restarts your computer, 
  504.   your system will return to its normal configuration.
  505.  
  506. 14. PC-NFS
  507. ==========
  508. If you use SETVER to report a different version of MS-DOS to a
  509. program, PC-NFS 3.x may report the version incorrectly. If you are
  510. having this problem, contact your network vendor for updated network
  511. software.
  512.  
  513. If you use PC-NFS 3.0 with MS-DOS Shell, MS-DOS Shell might display
  514. more drives than you have currently enabled. To prevent this, use the
  515. PC-NFS /D switch to specify the number of drives you are using. For
  516. more information, see your PC- NFS documentation.
  517.  
  518. If you can't use the COPY or XCOPY command on PC-NFS 3.01, contact
  519. your vendor to get an updated version of the PCNFS.SYS device driver.
  520.  
  521. If you use PC-NFS network software, carry out the following procedure
  522. before you run MemMaker:
  523.  
  524. 1. Open your MEMMAKER.INF file using any text editor. This file is
  525.    in the directory that contains your MS-DOS files.
  526.  
  527. 2. Add the following line to the file:
  528.  
  529.    *NET
  530.  
  531. 3. Save the file, and then run MemMaker.
  532.  
  533. 15. TCS 10Net or DCA 10Net 
  534. ==========================
  535. DCA 10Net Plus Versions 4.20 (20) and later, and DCA 10Net versions
  536. 3.3 (41) and later are compatible with MS-DOS 6.22. If you have an
  537. earlier version, contact your network vendor for an update.
  538.  
  539. If you are running a compatible version of 10Net Network Software,
  540. disable the network software, and then run MS-DOS 6.22 Setup. After
  541. you install MS-DOS 6.22, reenable your network software.
  542.  
  543. NOTE
  544. Microsoft Defragmenter program is incompatible with 10Net network
  545. software if the server service is loaded. If only the redirector is
  546. loaded, the program is compatible with 10Net network software.
  547.