  1.                      NOVELL NETWARE AND THE IBM AS/400
  2.  
  3. A few tweaks is all it takes to run concurrent NetWare and AS/4000 sessions
  4. on a Token Ring LAN
  5.  
  6. By using IBM's PC Support AS/4000 program, PC users can run a NetWare
  7. session at the same time as an AS/400 session.  To make it work, though,
  8. users must modify their CONFIG.SYS files prior to running the PC Support
  9. program.
  10.  
  11. The two main steps consist of adding several device drivers to your
  12. CONFIG.SYS file, then installing the PC Support program on your PC.  Two
  13. files are created when you run the installation routine:a CONFIG.PCS file
  14. and a STARTPCS.BAT file.  You'll need to obtain the appropriate
  15. configuration information from the AS/400 administrator in order to
  16. complete these steps.
  17.  
  18. GATHERING AS/400 INFORMATION
  19. Before you do anything, you need to get four pieces of information from the
  20. AS/400 administrator:
  21. -The remote network identifier
  22. -The remote control point name
  23. -The remote adapter address
  24. -The local adapter address
  25.  
  26. The first three come from the Advanced Program to Program Communications
  27. (APPC) Communication Controller Description screens; the last one comes
  28. from the Token Ring Line Description screens.  These screens are viewed on
  29. the AS/4000.
  30.  
  31. APPC CONTROLLER DESCRIPTION
  32. Figure 1 shows an example of the APPC Controller Description screens on the
  33. AS/400.  Three seperate screens are shown together in the figure.
  34.  
  35. Take a look at the values shown for the "Remote network identifier"
  36. (RMTNETID) and the "Remote control point name" (RMTCPNAME) on the second
  37. screen.  In the figure, they are the character strings "APPN" and "TOKEN".
  38. These values must match the RTLN parameters in your CONFIG.PCS file.  You
  39. will be prompted to enter these values when you run the PC Support
  40. installation program on your PC.  (This program creates the CONFIG.PCS
  41. file.)
  42.  
  43. Note also the value displayed on the third APPC Controller Description
  44. screen for the "TRLAN remote adapter address" (ADP-TADR).  In the figure,
  45. this address is 400044440001.  You will need to specify the remote adapter
  46. adapter as a parameter for the DXMCOMOD.SYS driver in your CONFIG.SYS file.
  47.  
  48. *************************************************************************** 
  49. FIGURE 1. SAMPLE APPC CONTROLLER DESCRIPTION ON the AS/400
  50.                    Display Contoller Description - APPC
  51. Controller description        CTLD           TOKEN1
  52. Link type                     LINKTYPE       *TRLAN
  53. Online at IPL                 ONLINE         *YES
  54. Switched line                 SWITCHED
  55. Short hold mode               SHM
  56. Switched network backup       SNBU
  57. Activate swt network backup   ACTSNBU
  58. APPN-capable                  APPN           *YES
  59. Attached nonswitched line     LINE
  60. Switched line list            SWTLINLST
  61.      TOKEN
  62.  
  63. Attached devices              DEV
  64.      TOKEN
  65. ---------------------------------------------------------------------------
  66. Character code                CODE           *EBCDIC
  67. Maximum frame size            MAXFRAME       1994
  68. Remote network identifier     RMTNETID       APPN
  69. Remote control point name     RMTCPNAME      TOKEN
  70. Exchange identifier           EXCHID
  71. Initial connection            INLCNN         *ANS
  72. Connection number             CNNNBR
  73.  
  74. Predial delay                 PREDIALDLY
  75. Redial delay                  REDIALLDY
  76. Dial retry                    DIALRTY
  77. Remote autoanswer             RMTAUTOANS
  78. Switched disconnect           SWTDSC         *YES
  79. Disconnect timer              DSCTMR         170
  80. Data link role                ROLE           *NEG
  81. SHM disconnect limit          SHMDSCLMT
  82. SHM disconnect timer          SHMDSCTMR
  83. -------------------------------------------------------------------------
  84. TRLAN remote adapter address  ADPTADR        400044440001
  85. TRLAN remote adapter address  DSAP           04
  86. TRLAN SSAP                    SSAP           04
  87. TRLAN frame retry             TRNFRMRTY      10
  88. TRLAN connect retry           TRNCNNRTY      10
  89. TRLAN response timer          TRNRSPTMR      10
  90. TRLAN connection timer        TRNCNNTMR      70
  91. TRLAN acknowlegement timer    TRNACKTMR      1
  92. TRLAN inactivity timer        TRNINACTMR     100
  93. TRLAN ack frequency           TRNACKFRQ      1
  94. TRLAN max outstanding frames  TRNMAXOUT      2
  95. TRLAN access priority         TRNACCPTY      0
  96. APPN CP session support       CPSSN          *YES
  97. APPN node type                NODETYPE       *ENDCODE
  98. APPN transmission grp number  TMSGRPNBR      1
  99.  
  100. Press Enter to continue
  101.  
  102. F3=Exit   F12=Cancel
  103. ***************************************************************************
  104.  
  105. TOKEN RING LINE DESCRIPTION
  106. Figure 2 shows an example of the Token Ring Line Description screens on the
  107. AS/400.  You need to define your Token Ring Line Description on the AS/400
  108. if it's not already defined.
  109.  
  110. As you can see in the figure, the value of the "Local adapter address"
  111. (ADPTADR) is 400003190001.  You will be prompted to enter this value when
  112. you install the PC Support program.  It must match the information
  113. parameter of the TRLI line specified in CONFIG.PCS.
  114. ***************************************************************************
  115. FIGURE 2: A SAMPLE TOKEN RING LINE DESCRIPTION ON THE AS/400
  116.                    Display Line Description - Token Ring
  117. Line description              LIND           TOKEN
  118. Resource name                 RSCRNAME       LIN031
  119. Online at IPL                 ONLINE         *YES
  120. Vary on wait                  VRYWAIT        *NOWAIT
  121. Network controller            NETCTL
  122. Maximum controllers           MAXCTL         20
  123. Maximum frame size            MAXFRAME       1994
  124. TRLAN Manager logging level   TRNLOGLVL      *OFF
  125.      Current logging level                   *OFF
  126. Local adapter address         ADPTADR        400003190001
  127. Exchange identifier           EXCHID         05600000
  128. Source service access points  SSAP
  129.      04
  130. -----------------------------------------------------------------------
  131. Error threshold level         THRESHOLD      *OFF
  132.  
  133. Link speed                    LINKSPEED      4M
  134. Cost/connect time             COSTCNN
  135. Cost/byte                     COSTBYTE       0
  136. Security for line             SECURITY       *NONSECURE
  137. Propogation delay             PRPDLY         *LAN
  138. User-defined 1                USRDFN1        128
  139. User-defined 2                USRDFN2        128
  140. User-defined 2                USRDFN3        128
  141. Recovery limits               CMNRCYLMT      
  142.      Count limit                             *SYSVAL
  143.      Time interval            
  144. Text                          TEXT           Token Ring Line
  145. Description
  146.  
  147. Press Enter to continue
  148.  
  149. F3=Exit   F12=cancel
  150. ***************************************************************************
  151. MODIFYING CONFIG.SYS
  152. Figure 3 lists a sample CONFIG.SYS file showing the modifications that must
  153. be made.  The device drivers come on the "LAN Support" diskette that
  154. accompanies each Token Ring adapter.  Your CONFIG.SYS must include all of
  155. the drivers shown.  The parameters that follow some of the drivers are
  156. explained below.  The "001" after the DXMAOMOD.SYS driver indicates that
  157. the Token Ring adapter installed in the PC is a Primary Adapter.
  158.  
  159. The number after the DXMCOMOD.SYS driver (400044440001) is the "TRLAN
  160. remote adapter address" from the AS/400 APPC Controller Description screen. 
  161. This address will overide the default address encoded on your PC's Token
  162. Ring adapter.
  163.  
  164. The DXMTOMOD.SYS driver has five parameters, which are listed below:
  165. > ES=2 indicates how many additional SAPs (Service Access Points) can be
  166. requested by the NetBios Interface Device Driver when it implicity opens
  167. the Token Ring adapter.  Both NetWare and the PC Support program uses one
  168. SAP each, so you need at least SAPs to run these two concurrently.
  169. > EST=6 indicates the number of additional kink stations requested by the
  170. NetBios Interface Device Driver when it implicity opens the Token Ring
  171. adapter.
  172. > S=8 indicates the number of NetBios Interface sessions that may be
  173. defined.
  174. > C=18 indicates the number of NetBios Interface Commands (NCBs) that may
  175. be outstanding at one time.
  176. > DS=2048 indicates the size of the Token Ring adapter transmit buffers
  177. (DHBs) in bytes.
  178.  
  179. Note that the above information applies only to version 1.2 ofg the AS/400
  180. Operating System.  With version 2.0 you don't need to specify any
  181. parameters following the DXMTOMOD.SYS driver.  (For more information on
  182. configuring the DXMTOMOD.SYS driver, consult your IBM Local Area Network
  183. Support Program documentation.)
  184.  
  185. The "drives=" parameter for the ECYDDX.SYS driver indicates the number of
  186. drives to be allocated to shared folders.  This is a key value because, by
  187. default, eight driver (drives D through K) are allocated to shared folders. 
  188. If you don't change the default, NetWare drive F will be shifted to drive
  189. L.  By changing this value to "drives=2," only drives D and E are allocated
  190. to shared folders.  NetWare will be able to use from drive F on as it
  191. normally does.
  192. ***************************************************************************
  193. FIGURE 3: NECESSARY MODIFICATIONS TO THE CONFIG.SYS file.
  194. Files=20
  195. Buffers=20
  196. Device=\DXMAOMOD.SYS 001
  197. Device=\DXMCOMOD.SYS 4000444400001
  198. Device=\DXMTOMOD.SYS ES=2 EST=6 S=8 C=18 DS=2048
  199. Device=C:\EIMPCS.SYS
  200. Device=C:\ECYDDX.SYS files=8 drives=2
  201. Device=C:\FSDD.SYS
  202. ***************************************************************************
  203. INSTALLING PC SUPPORT AS/400
  204. Next, you need to install the PC Support AS/400 application on a PC
  205. connected to a NetWare LAN via a Token Ring adapter. (PC Support software
  206. can run independent of a NetWare LAN).
  207.  
  208. Consult your "PC Support AS/400 User's guide" on how to run the INSTALL
  209. command.  The INSTALL routine creates a CONFIG.PCS file and places it in
  210. the subdirectory C:\PCS (or in another subdirectory if you so specify).
  211.  
  212. Figure 4 shows a sample CONFIG.PCS file.  You will be prompted for the
  213. RTYP, RTLN, and TRLI parameters  when you run the PC Support INSTALL
  214. program.  RTYP should always be "ITRN" for Token Ring Interface.  The two
  215. RTLN paqrameters should match the RMTNETID and RMTCPNAME values shown on
  216. the AS/400.  In our example, these "APPN" and "TOKEN".
  217.  
  218. The "400003190001" parameter shown for TRLI is the AS/4000 Token Ring LIne
  219. address on the AS/400.  All PCs on the LAN should use this line address
  220. when they run a NetWare session.
  221. **************************************************************************
  222. FIGURE 4:CONFIG.PCS file created by the AS/400 PC Support Program
  223. RTYP ITRN
  224. RTLN APPN.TOKEN
  225. TRLI NOVELL,400003190001
  226. ***************************************************************************
  227. RUNNING THE PC SUPPORT PROGRAM
  228. A batch file STARTPCS.BAT is  created as part of the INSTALL process. (see
  229. Figure 5).
  230.  
  231. Since with NetWare we are using only two drives (drives D and E) dor AS/400
  232. shared folders, chheck your STARTPCS.BAT file and change any reference to
  233. Drive I to drive D or E.  (All such references in the sample batch file
  234. have been modified to drive E).
  235.  
  236. Once you've made these changes to your batch file, type "STARTPCS" at your
  237. PC to start the PC Support AS/400 program.  For more information on the
  238. STARTPCS.BAT file, consult your "PC Support AS/400 User's Guide".
  239. ***************************************************************************
  240. FIGURE 5: The STARTPCS.BAT batch file created by the INSTALL program.
  241. STARNRTR CONFIG.PCS ECHO OFF IF ERRORLEVEL 20 GOTO EXIT
  242. ECHO ON
  243. FSPC ASSIGN E:QIWSFLR
  244. ECHO OFF
  245. IF ERRORLEVEL 200 GOTO EXIT
  246.  
  247. ECHO ON
  248. E:PCSUPDT E:\PCS
  249. ECHO OFF
  250. IF ERRORLEVEL 20 GOTO EXIT
  251.  
  252. ECHO ON
  253. E:STARTMSG CONFIG.PCS
  254. ECHO OFF
  255. IF ERRORLEVEL 20 GOTO EXIT
  256.  
  257. ECHO ON
  258. E:VPRT
  259. ECHO OFF
  260. IF ERRORLEVEL 200 GOTO EXIT
  261.  
  262. ECHO ON
  263. E:WSF/T
  264. ECHO OFF
  265. IF ERRORLEVEL 20 GOTO EXIT
  266. IF NOTERRORLEVEL 10 GOTO SKIP
  267. ECHO ON
  268. E:STARTWSF 1
  269. ECHO OFF
  270. :SKIP
  271.  
  272. ECHO ON
  273. E:PCO CONFIG.PCS
  274. ECHO OFF
  275. :EXIT
  276. ECHO ON
  277. *************************************************************************** 
  278.                                                                            
  279.                                                                            
  280.                                                                            
  281.                             
  282.  
  283.  
  284.  
  285.  
  286.  
  287.                     
  288.  
  289.