  1.  
  2.               NOVELL TECHNICAL INFORMATION DOCUMENT
  3.  
  4. TITLE:              UPS Patch for NetWare 2.2
  5. DOCUMENT ID:        TID000415
  6. DOCUMENT REVISION:  A
  7. DATE:               01JUL93
  8. ALERT STATUS:       Yellow
  9. INFORMATION TYPE:   Symptom Solution
  10. README FOR:         UPS22.EXE
  11.  
  12. NOVELL PRODUCT and VERSION:
  13. NetWare 2.2
  14.  
  15. ABSTRACT:
  16. This NetWare 2.2 patch fixes a problem with IBM PS/2 Models with TYPE II
  17. keyboard controllers when used with the NetWare UPS monitoring feature
  18. through the mouse port.  The problem only occurs on the IBM PS/2 Models
  19. with TYPE II Keyboard
  20. _________________________________________________________________
  21.  
  22. DISCLAIMER
  23. THE ORIGIN OF THIS INFORMATION MAY BE INTERNAL OR EXTERNAL TO NOVELL. 
  24. NOVELL MAKES EVERY EFFORT WITHIN ITS MEANS TO VERIFY THIS INFORMATION. 
  25. HOWEVER, THE INFORMATION PROVIDED IN THIS DOCUMENT IS FOR YOUR INFORMATION
  26. ONLY.  NOVELL MAKES NO EXPLICIT OR IMPLIED CLAIMS TO THE VALIDITY OF THIS
  27. INFORMATION.
  28. _________________________________________________________________
  29.  
  30. Self-Extracting File Name:  UPS22.EXE
  31.  
  32. Files Included     Size     Date        Time
  33.  
  34.    UPS22.TXT          (This File)
  35. UPSPATCH.VAP       6272    9-26-91     12:45a
  36.  
  37.  
  38. PROBLEMS ADDRESSED:
  39. This fix is intended for NetWare 286 v2.2 (5, 10, 50, 100 users). This
  40. patch fixes a problem encountered by users of IBM PS/2 Models with TYPE II
  41. keyboard controllers when used with NetWares UPS monitoring feature through
  42. the mouse port. This problem only occurs on the IBM PS/2 Models with TYPE
  43. II Keyboard controllers.  TYPE II controllers are included with all model
  44. 90's and 95's, all type 38570-E61 Model 70's, all Model 30's, and all Model
  45. 35's.
  46.  
  47. This fix is needed if the following symptom is seen: At the file server
  48. console, the "Battery Low" message will be displayed when UPS monitoring is
  49. enabled and the keyboard at the file server is used.  This will occur on
  50. both dedicated and nondedicated file servers.  If the user keeps working at
  51. the file server after receiving this message, the server will shut down.
  52.  
  53.  
  54. IMPLEMENTATION:
  55.  
  56. 1.   Copy UPSPATCH.VAP into the SYS:SYSTEM directory.
  57.  
  58. 2.   DOWN the file server and bring it back up.  Load the VAP at the file
  59. server console by responding "y" at the prompt "Value Added Processes have
  60. been defined. Do you wish to load them?"  You may want to have the VAPs
  61. load automatically by modifying the SERVER.CFG. (See the manual USING THE
  62. NETWORK v2.2, page 13).
  63.  
  64. 3.   If loading other VAPs, this UPSPATCH.VAP should be loaded first.  This
  65. can be effected by renaming this UPSPATCH.VP0, and renaming the other VAPs
  66. XXX.VP1, XXX.VP2, ....
  67.  
  68. 4.   To confirm that the UPSPATCH.VAP has been loaded, type the console