NOVELL TECHNICAL INFORMATION DOCUMENT
TITLE: UPS Patch for NetWare 2.2
DOCUMENT ID: TID000415
DOCUMENT REVISION: A
DATE: 01JUL93
ALERT STATUS: Yellow
INFORMATION TYPE: Symptom Solution
README FOR: UPS22.EXE
NOVELL PRODUCT and VERSION:
NetWare 2.2
ABSTRACT:
This NetWare 2.2 patch fixes a problem with IBM PS/2 Models with TYPE II
keyboard controllers when used with the NetWare UPS monitoring feature
through the mouse port. The problem only occurs on the IBM PS/2 Models
with TYPE II Keyboard
_________________________________________________________________
DISCLAIMER
THE ORIGIN OF THIS INFORMATION MAY BE INTERNAL OR EXTERNAL TO NOVELL.
NOVELL MAKES EVERY EFFORT WITHIN ITS MEANS TO VERIFY THIS INFORMATION.
HOWEVER, THE INFORMATION PROVIDED IN THIS DOCUMENT IS FOR YOUR INFORMATION
ONLY. NOVELL MAKES NO EXPLICIT OR IMPLIED CLAIMS TO THE VALIDITY OF THIS
INFORMATION.
_________________________________________________________________
Self-Extracting File Name: UPS22.EXE
Files Included Size Date Time
UPS22.TXT (This File)
UPSPATCH.VAP 6272 9-26-91 12:45a
PROBLEMS ADDRESSED:
This fix is intended for NetWare 286 v2.2 (5, 10, 50, 100 users). This
patch fixes a problem encountered by users of IBM PS/2 Models with TYPE II
keyboard controllers when used with NetWares UPS monitoring feature through
the mouse port. This problem only occurs on the IBM PS/2 Models with TYPE
II Keyboard controllers. TYPE II controllers are included with all model
90's and 95's, all type 38570-E61 Model 70's, all Model 30's, and all Model
35's.
This fix is needed if the following symptom is seen: At the file server
console, the "Battery Low" message will be displayed when UPS monitoring is
enabled and the keyboard at the file server is used. This will occur on
both dedicated and nondedicated file servers. If the user keeps working at
the file server after receiving this message, the server will shut down.
IMPLEMENTATION:
1. Copy UPSPATCH.VAP into the SYS:SYSTEM directory.
2. DOWN the file server and bring it back up. Load the VAP at the file
server console by responding "y" at the prompt "Value Added Processes have
been defined. Do you wish to load them?" You may want to have the VAPs
load automatically by modifying the SERVER.CFG. (See the manual USING THE
NETWORK v2.2, page 13).
3. If loading other VAPs, this UPSPATCH.VAP should be loaded first. This
can be effected by renaming this UPSPATCH.VP0, and renaming the other VAPs
XXX.VP1, XXX.VP2, ....
4. To confirm that the UPSPATCH.VAP has been loaded, type the console
command "VAP" to list all VAPs that are currently loaded.