NOVELL TECHNICAL INFORMATION DOCUMENT
TITLE: PTF410 - NetWare SAA 1.3 Maintenance
DOCUMENT ID: TID250010
DOCUMENT REVISION: B
DATE: 25MAR94
ALERT STATUS: Yellow
INFORMATION TYPE: Symptom Solution
README FOR: PTF410.EXE
NOVELL PRODUCT and VERSION:
NetWare for SAA 1.3
ABSTRACT:
PTF410, 411, 412, 413, 414, and 415 files together are the latest Maintenance
PTF for NetWare for SAA 1.3. (PTF412 and 413 are required for NetWare 3.11
ONLY) *BEFORE YOU UNZIP THESE FILES, YOU MUST READ DOWNLOAD AND READ
PTF41X.TXT. The PTF41X series allows NetWare for SAA to run on a NetWare 4.x
server; it also contains all the latest patches and additional features. The
PTFs update NetWare for SAA 1.3 to 1.3.43. (effectively the same as 1.3.42,
which is shipping as "1.3B"). After you have applied these PTF files, you may
apply the PTF443.EXE patch.
──────────────────────────────────────────────────────────────────────────────
DISCLAIMER
THE ORIGIN OF THIS INFORMATION MAY BE INTERNAL OR EXTERNAL TO NOVELL. NOVELL
MAKES EVERY EFFORT WITHIN ITS MEANS TO VERIFY THIS INFORMATION. HOWEVER, THE
INFORMATION PROVIDED IN THIS DOCUMENT IS FOR YOUR INFORMATION ONLY. NOVELL
MAKES NO EXPLICIT OR IMPLIED CLAIMS TO THE VALIDITY OF THIS INFORMATION.
──────────────────────────────────────────────────────────────────────────────
ADDITIONAL CONFIGURATION
Other:
GENERAL
SYMPTOM
If two DownStream PUs were configured with the same address, it was
sometimes not detected causing an error message and the eventual crash of
NetWare for SAA.
SOLUTION
Apply the PTF 41X series.
SYMPTOM
Auto-disconnect/connect not working with QLLC and downstream PUs.
SOLUTION
Apply the PTF 41X series.
SYMPTOM
Sometimes when messages pertaining to the link status used, remained
queued showing only one links' status. If there were several downstream
links this resulted in resources not being released when the SNA profile
was unloaded.
SOLUTION
Apply the PTF 41X series.
The DLCI code has been changed so that all messages pertaining to link
status will be displayed at all the times.
SYMPTOM
Incorrect sense code displayed from a received XID3.
SOLUTION
Apply the PTF 41X series.
An incorrect sense code will no longer be displayed from a received XID3.
SYMPTOM
If a SNA profile was unloaded in the middle of data transfer there were
problems reconnecting until DLM, protocol stack, and driver were started
again.
SOLUTION
Apply the PTF 41X series.
SYMPTOM
Workstations sometimes crashed because C-Worthy was freeing memory
addressed by uninitialized pointers, when using CSCON.
SOLUTION
Apply the PTF 41X series.
SYMPTOM
Incorrect display of PU 2.1 LU numbers.
SOLUTION
Apply the PTF 41X series.
A change was made so that PU 2.1 LU numbers display correctly from LU1 to
LU 128 for independent LUs.
SYMPTOM
Some segments not counted for NMA number of bytes received count.
SOLUTION
Apply the PTF 41X series.
A change was made to SNA to fix the number of bytes received count for
NetWare Management Agent statistics. Previously, all segments (FIS, MIS,
LIS) were not counted.
SYMPTOM
The number of UP-BOUND LUs was incorrectly reported to SSM when requests
were made for specific attributes of a Host Link object. This value was
being overwritten by the value for UP-INACTIVE LU count.
SOLUTION
Apply the PTF 41X series.
SYMPTOM
If OS/2 CM was a DSPU, (and if the host sent segmented FMD RUs under a
SSCP-LU session, host link would constantly connect and disconnect.
SOLUTION
Apply the PTF 41X series.
SYMPTOM
RequestID reset.
SOLUTION
Apply the PTF 41X series.
NMAUTIL was changed to set the request ID correctly so that when the host
sends more than 15 RUNCMDS, the requestID does not reset.
SYMPTOM
On a NetWare 4.01 LAN, API errors occurred when CSCON was brought up.
SOLUTION
Apply the PTF 41X series.
SYMPTOM
System Log pages not formatted correctly.
SOLUTION
Apply the PTF 41X series.
The code for maintaining the SYSTEM.LOG has been modified to format the
pages correctly. SYSTEM.LOG files are now named according to the service
profile name. When the file reaches .5 MB, it is saved as
"<profilename>.log>." Writes to the SYSTEM.LOG have also been
streamlined to work faster.
ADDITIONAL CONFIGURATION
Other:
AS/400
SYMPTOM
If AUTOEXEC.NCF had the following consecutive statements, the following
message was displayed:
AUTOEXEC.NCF Statements
CSLOAD SNAPROF
LOAD AS400PCS
MESSAGE
AS400PCS unloads with "AS400PCS - SNA profile name is known, but..."
SOLUTION
Apply the PTF 41X series.
PB_NWSAA has been modified so AS400PCS will not unload with the error if
the previously mentioned lines are in the AUTOEXEC.NCF file.
ADDITIONAL CONFIGURATION
Other:
SNA LINKS
SYMPTOM
When "Set Msg Destination" was selected, the server would hang.
SOLUTION
Apply the PTF 41X series.
ADDITIONAL CONFIGURATION
Other:
LU6.2
SYMPTOM
In CSSTATUS, if there were multiple or parallel sessions, all attributes
did not display.
SOLUTION
Apply the PTF 41X series.
SYMPTOM
The LU6.2 transaction program sometimes hung if allocate was done and the
link went down.
SOLUTION
Apply the PTF 41X series.
SYMPTOM
A LU 6.2 protocol violation occurred when the Change Direction Indicator
was being incorrectly set by NWSAA in a LUSTAT, which was causing the
partner LU to UNBIND.
SOLUTION
Apply the PTF 41X series.
SYMPTOM
MC_TEST, when issued from SEND state was erroneously returning the return
codes of STATE_CHECK and NOT_RCV_STATE.
SOLUTION
Apply the PTF 41X series.
After the installation of the PTF, the MC_TEST verb can be issued when
the conversation is in any state.
SYMPTOM
The Transaction Program would hang because the protocol stack was
waiting on Change Direction before sending FMH-7 (to service SEND_ERROR
verb).
SOLUTION
Apply the PTF 41X series.
ADDITIONAL CONFIGURATION
Other:
QLLC
SYMPTOM
If a remote target X.25 address was not configured correctly, the
resources allocated were not freed after the configuration was corrected.
Instead, they were not released until the unload of QLLCS.
SOLUTION
Apply the PTF 41X series.
SYMPTOM
DISPLAY_CV22_MSG incorrectly displayed QLLC target names.
SOLUTION
Apply the PTF 41X series.
SYMPTOM
QLLCS not working with downstream PUs during reconnection.
SOLUTION
Apply the PTF 41X series. With these files applied, QLLCS will now work
with downstream PUs during the reconnection process.
ADDITIONAL CONFIGURATION
Other:
SDLC
SYMPTOM
If the SNA profile loaded and unloaded before SDLC link was up, DTR
stayed on even after the unload.
SOLUTION
Apply the PTF 41X series.
SYMPTOM
If two SNA profiles were on the same SDLC card; when the first profile
was unloaded, DTR went down causing the link to disconnect. This in turn
caused the second profile to get disconnect also.
SOLUTION
Apply the PTF 41X series.
SYMPTOM
No alert message when link activity timer expires.
SOLUTION
Apply the PTF 41X series. With these files applied, two new alert
messages have been added for frame reject condition.
SYMPTOM
Disconnect message not displayed.
SOLUTION
Apply the PTF 41X series. With these files applied, an inactivity timer
alert message will now display when the link activity timer expires.
SYMPTOM
SDLCS (SDLC protocol stack) on a V.35 link, when using multidrop feature
on R3SDLC card, would not display a link disconnected message if the host
link was inactivated.
SOLUTION
Apply the PTF 41X series, which correct the Link lost problem when using
multidrop feature on R3SDLC card with V.35 link.
SYMPTOM
When the host link was inactivated, sometimes all the sessions showed Up
Status and the link never showed disconnect status.
SOLUTION
Apply the PTF 41X series.
ADDITIONAL CONFIGURATION
Other:
Token-Ring
SYMPTOM
The Token Ring would flood with XIDs if the host was not ready to bring
up the link.
SOLUTION
Apply the PTF 41X series.
Self-Extracting File Name: PTF410.EXE Revision: B
Files Included Size Date Time
\
PTF410.TXT (This File)
3X.TXT 18166 09-29-93 6:31p
4X.TXT 22236 09-27-93 5:01p
PTF41X.TXT 4852 09-29-93 6:30p
COMMEXE1.ZIP 490118 09-27-93 11:06a
Note: These are only the files in PTF410. See the .TXT files in PTF
411, 412, 413, 414, and 415 for the file listing of each of PTF.
Installation Instructions:
*** WARNING ***
Failure to read PTF41X.TXT first may cause you do perform procedures
incorrectly and problems with your files may occur.
1. Do not simply copy the files, FIRST, read PTF41X.TXT.
2. To install on a NetWare 3.11 or 3.12 server, please read 3X.TXT.
3. To install on a NetWare 4.0 or 4.21 server, please read 4X.TXT.
*** Do not simply copy the files in, you MUST follow the instructions
listed above. ***
Patch History:
The PTF 41X series supersedes PTF 400, 401, 402, 403, 404, and 406. It
also supersedes PTF 354, 367, and 368.
Solution Specifics:
NEW FEATURES
1. TRFORMAT.EXE now decodes LUx information.
2. HELP file added to WEEAS for OS/2 access support.
3. SNMP alert support for NMS, added generic MLID object for
third-party driver support.
4. NetWare Management Agent
a. Remote 3 adapter now compatible with SSM.
b. Flow of NetView alerts is now restricted if a limit is
exceeded. This is configurable through NVCMDS.DB.
c. A NetView alert will be generated if registered end point
servers go down.
d. Allow RUNCMD retry limit, retry timer and response timer are
now configurable through NVCMDS.DB. This replaces the
configuration available previously in NetWare for SAA 1.2
through CSPARM.
e. Allow APPL names in runcmds to eight characters without
padding.
5. Support was added for License diskette.
6. CPIC and AS/400 file names now conform to the CD-ROM ISO convention.
7. Two additional NetView alerts can now be generated:
- File server error limit reached: Server configuration
- Failure Alert: THRESHOLD REACHED
These alerts mean the number of NetView alerts generated by the
collection point and end point servers has exceeded the
HIGHWATERMARK parameter setting in NVCMDS.DB.
Alert forwarding to the NetView console has been stopped until the
number of generated alerts drops to or below the LOWATERMARK setting
in NVCMDS.DB.
Action: Request the LAN administrator to check for LAN conditions
that may be generating excessive NetView alerts. Check
the HIGHWATERMARK setting in NVCMDS.DB on the collection
point server and raise it if it is set too low.
_________________________________________________________________
DISCLAIMER
Novell, Inc. makes no representations or warranties with respect to this
software program, and specifically disclaims any express or implied
warranties of merchantability, title, or fitness for a particular purpose.
Novell's intentions for this software program is to provide a temporary
workaround to the anomalies described in this document. Such workarounds are
typically addressed in future releases of the product.
Novell will not be responsible for any data loss that may result from
implementing this program. Novell strongly recommends a backup be made
before any program is applied. Technical support for this program is
provided at the discretion of Novell.
_________________________________________________________________