home *** CD-ROM | disk | FTP | other *** search
/ TAP YIPL / TAP_and_YIPL_Collection_CD.iso / TAPS / TAP4 / TAP27.TXT < prev    next >
Text File  |  1999-10-13  |  19KB  |  339 lines

  1.  
  2. =======================================
  3. =                                     =
  4. =            TAP issue #27            =
  5. =                                     =
  6. =            November 1974            =
  7. =                                     =
  8. =       Retyped By: The Lineman       =
  9. =                                     =
  10. =   For Atlantis BBS (215)844-8836    =
  11. =                                     =
  12. =         Thanks Sigmond Fraud        =
  13. =                                     =
  14. =======================================
  15.  
  16.     Yes, after 6 months in the pits we're back! Our unannounced vacation took
  17. place for several reasons the main one being a shortage of help and a surplus
  18. of work. By now we have sold alot of back issues & the income has helped to put
  19. to put us solidly in the black.
  20.     We will try to come out fairly regularly from now on, but this depends also
  21. on reader contributions & printing costs. We are also planning a Convention and
  22. need ideas for the convention from everyone. Possibly contests and exhibits and
  23. such. Please write to us if you've got suggestions.
  24.     In addition, we will be having technical seminars as always. If you are
  25. well-versed in any phase of phreaking covered in TAP or otherwise, please get
  26. in touch with us to teach at the convention.
  27. Dear TAP,
  28. Checking the guide to Subversive Organizations and Publications (House document
  29. 398) I noticed the absence of TAP or TIPL-Then I noticed the date was 1961. Did
  30. you make the new list?
  31. Anyway, tell your readers that it's  illegal to remove the dialing instruction  plate on payphones (below dial) if they were planning on using a high carbon   
  32. bit on a hand drill to drill a hole exactly 2 3/4" to the right and 5/8" down.
  33. Not only is it illegal, but if the end of a paperclip through a hold it would
  34. to alsorts of terible things like releasing all the money they just put in to
  35. make a long distance call, preventing them from supporting the wonderfUl phone 
  36. company. (Note- drill will cut through iron case, through not steel lock or 
  37. coin box.)
  38.                -New York-
  39.  
  40.     -Add the dialing instruction plate could be put back in, obscuring the hole and allowong nefarious indviduals to continue their plindering-TAP
  41.  
  42. Dear TAP,
  43. On a recent trip to Paris I was able to make free calls to any point in the US
  44. (exept Hawaii) and Europe from a special yellow public telephone booth situated all over Paris caled "Interurbain". The only catch was that the called party had to be muted otherwise a loud tone makes conversation impossible. As you know, 
  45. the mute prevents supervision, on overseas trunks this is accomplished by 
  46. sending 2400Hz to the calling party C.O., indication that the called party has 
  47. answered. It is the lack of the 2400 Hz tone which prevents the loud blocking 
  48. tone from coming on the paris phone.
  49.      Wait for dial tone, dial 19, wait for a second dial tone, then dial 1 + 
  50. area code + number. I tried to off a 800 or 555 number, but you can't dial them for that matter with an SF. I'm not sure, but you might be able to do this from
  51. other European cities. I believe that the black box is international, since
  52. most European telephone systems are still step or crossbar.
  53.            -New York-
  54.  
  55.  N E W  B L U E  B O X  I N F O
  56.  -----  -------  -----  -------
  57.  
  58.       We've gotten feedback on the New Blue Box Circuit (Issue 26). One problem of the circuit is that all the diodes for one frequency must be matched. The 
  59. motorola Silicon dual diode MSD 6150 (common anode) saves PC board space and is a matched pair. $.25 each in 100 quantity. If regular diodes are to be used, 
  60. use only silicon. Though we said germanium diodes are ok, they usually have too much leakage current and the pots will cross-affect each other.
  61.      In fact, you can eliminate the hassle and matching of diodes altogether by
  62. using double-pole push-buttons. Polypaks sells a $6.88 General Telephone Data
  63. entry keyboard with 10 buttons. You'll need 2 more DPST and a SPST for 2600,
  64. but you'll save money on diodes. The same 10 tripots are used. And keep the
  65. wiring to the pots and switches good and secure electrically. A loose
  66. connection is a changing frequency. We also have an unchecked report that
  67. elimination diodes with double pole switches makes the regulator unnecessary.
  68.  
  69. Dear TAP,
  70. As for picking Medeco and Keso locks you can forget it. Medeco is a sidebar
  71. type of lock like the Griggs and Stratton locks G.M. uses in their cars.
  72. Locksmiths usually use codes for auto locks as they can't pick them. A more
  73. efficient method for vending machines would be to use an awl & 5 lb. hammer to
  74. make a hole in the sheet metal of the cabnet and then a nibbling tool (for
  75. electronic construction) to enlarge the hole enough to reach in and disengage
  76. the lock cylinder from the locking bolts. The nibbles can be bought at
  77. Lafayette or Radio Shack but may not cut through all thickness of machine
  78. doors.
  79.                     -COLORADO-
  80.  
  81. Dear TAP,
  82. Acording to N.E.T. news line, you people are breaking the state law of Mass.
  83. when you published the 1975 Credit Card Code. Upon conviction you can be fined
  84. $2000 and get a year in the slammer. When I heard this I called the head of
  85. Security in Boston with a phoney c.c. number and told him what I was doing,
  86. Then I asked him what he was going to do about it. Was he ever pissed off.
  87. Yours in conspiricy
  88.  
  89.                 -Stainless Steel Rat
  90. A new system from Telident Inc. connects to any telephone and displays the
  91. incoming caller's number. Its purpose is to help catch obscene and other
  92. objectionable phone callers. The caller's number and exchange remain visible
  93. throughout the call:this pinpoints any pone being used for the obscene call,
  94. whether its a private or pay phone. The maker says the system will also
  95. discourage those making bomb threats or ransom demands, if you are bothered
  96. with those problems
  97.  
  98. Telident, Inc. 304 S Broadway, Los Angeles
  99.  
  100. MORE FREE ELECTRICITY
  101. ---- ---- -----------
  102.  
  103.      Our article on Free Electricity prompted a great reader response and we've
  104. got more info on how to do it. Several meters were sent to us and we've learned
  105. alot about how they work.
  106.      Several readers suggested that the speed-adjust screws do work but not
  107. very well and are sometimes labeled backwards to confuse Robin Hoods. However,
  108. we tested the New York standard meter which is a Westing house DSN, and found
  109. that the front screw was labeled correctly (F for Fast is counterclockwise) and
  110. could reduce the meter by 40% And the screw on the side can make the meter
  111. start moving in the wrong direction if you turn it enough! These revekatuibs
  112. are very encouraging indeed. The other meters also have adjustment screws, and
  113. one unmarked meter with large brown coils inside had 5 speed adjustment screws!
  114.      Most home meters are of the 220 volt dual-phase (3-wire) type which
  115. supplies 110 and 220 volts "hot" wires that are out of phase with each other,
  116. which means ground wire. From either hot wire to ground is 110 volts. One
  117. reader writes in that on 220 volt, GE single phase meters, about a 50%
  118. reduction in rotor speed can be obtained by wiring the potential coil so it
  119. receives only 110 volts, not 220. The Potential coil is the small coil wound
  120. out of thin wire & connected in shunt across  the load side of the meter.
  121. This accomplished as follows:
  122. 1. Remove meter from socket. (issue 23)
  123. 2. Remove case from meter (usually screws)
  124. 3. Locate the 2 small wires that are connected to the two line terminal (bottom
  125. two terminals).
  126. 4. Disconnect either of these wires (but not both), from the line terminal its
  127. attached to.
  128. 5. Connect it to the ground terminal. This is the smallest prong on the back of the meter and usually points a different way(like horizontal). Of course, but
  129. on the inside of the back as the ground terminal goes through the plastic back
  130. of the meter.
  131. 6. Get electric heat. Its cheaper!
  132.  
  133.     o---------/\/\/\/\/\----------o
  134.      Current             |
  135. LINE   Coils         -----     LOAD
  136.                   [::| Voltage coil
  137.                      -----     o Ground
  138.                          |      prong
  139.     o---------/\/\/\/\/\----------o
  140.  
  141.       Excuse this but this is normal GE meter
  142.  
  143.       Half speed meter.
  144.  
  145.     o---------/\/\/\/\/\----------o
  146. Line  current            |
  147.         coils        -----      LOAD
  148.                   [::|           o
  149.                      -----------/
  150.                            Ground prong
  151.     o---------/\/\/\/\/\----------o
  152.  
  153.      Before doing this you should make sure taht your meter has the same hookup as the GE meter used in the above letter. Some meters have a different hookup. 
  154. For example, the Westinghouse DSN has a voltage coil across one side of the 
  155. line and ground.
  156.  
  157.     o------/\/\/\/\/\/\/+----+---o LOAD
  158.               Resisters-:    \
  159.                      \  |    / Voltage
  160.                       \ |    \ Coil
  161.               Neon bulb\+---------o
  162.                         :      Ground
  163.                         |       Prong
  164.     o------/\/\/\/\/\/\/+--------o
  165.  
  166. NORMALLY. So this CAN'T be "Halved". The Duncan 12S has TWO voltage coils, one 
  167. from each side of the line to ground. One controls the reading of your 110 volt
  168. appliances, and other controls the reading of your 220 volt appliances. On this
  169. meter, the meter will have to be tested to see which voltage is controlled by 
  170. the two screws on the back. Turn on a 220 volt appliance (with the screws 
  171. loosened and the metal piece pulled out) and see if the wheel turns faster. If 
  172. it does, the screws control your 110 volt appliances. If not, then your air conditioner and other 220 volt units will only cost half as much.
  173.  
  174.     o------/\/\/\/\/\/\/+--------o
  175.                         ! meter dis-
  176.          !/\/\/\/\/\====- able screws
  177.          !_______________________o
  178. voltage  !             Ground prong
  179.   coils  !/\/\/\/\/\_____
  180.                          !
  181.     o------/\/\/\/\/\/\/\+-------o
  182.  
  183.        Duncan 12s
  184.  
  185. /\=Colis
  186. = = screws
  187.  
  188.      All the meters we tested have 5 prongs. Two are the input, Two are the
  189. output and one is ground. Disconnecting the ground stops the meter but leaves
  190. you with the lights on. Breaking off the pin and putting back the meter is good
  191. but less suspicion will be aroused if you bend the prong (the ground prong is
  192. the odd one out of place from the others and pointed a different way) so that
  193. it doesn't go in it's socket. In the Westinghouse meter they havea cute circuit
  194. to show whether this has been done. Disconnecting the ground or another wire
  195. makes a neon light in the meter glow, alerting the meter reader. If you have
  196. this type of meter, you can disconnect the bulb, or remove it and blow it out.
  197. Just make sure it looks like it's working but simply not lit. To blow out the
  198. bulb, hook it in series with a 500 ohm resister of 10 watts of more to a wall
  199. socket and let it slowly burn itself out.
  200.      We're told that a GE type 1-60-S meter can be slowed down 4%(every little
  201. bit helps!) with the adjustment screw, but as in all meters, GENTLY!. You dont
  202. want to damage the meter.
  203.      It's also been suggested that to remove the seals that hold the meter
  204. closed, just snip it as close to the plastic or lead part and bend the end over
  205. so that it will grip the inside of the hole again when it's re-used.
  206.      Another idea is to simply turn over the meter and it will run reverse,
  207. unfortunatly this is easy for a meterman to spot and is usually impossible with
  208. 5-prong meters which are most common.
  209.      Most electric companies estimate your bill for several months and adjust
  210. it when the meter is actually read, which is less often then every month. It's
  211. good to know, however, when the man actuallu comes if your setup is slightly
  212. detectable. If he's on to you, does anyone know if it's legal to offer him a
  213. present to keep it in the family? (Not for him, but for you). Let's hear from
  214. the lawyers out there.
  215.  
  216. Dear TAP,
  217. For your edification, I'm enclosing a photocopy of the current ITT Telex guide
  218. showing coumtry codes. If you have access to a teleprinter, you can access the
  219. ITT system quite easily by dialing 710-599-3211. Dita Beard will welcome you
  220. Many Universities have time-sharing computer terminals that could be used. You
  221. know, I assume, that the code for TWX operators is 954-1212. You can dial most
  222. any big-city area code plus the code and get the operator.
  223.      More commoin than mail tampering is the MAIL WATCH. The postman delivers
  224. your mail--but he makes a record of the return address on every piece.
  225. Recommended: a Canadian post office box. Ever since Lee Harvey Oswald, American
  226. Postmasters have required positive ID from prospective box renters. No so in
  227. Canada, and the price is right-about $10/year in small towns. Good for ordering
  228. reagents.
  229.      We understand that the British Post Office and Scotland Yard are now
  230. battling the SILVER BOX (also know as a 'Bleep'). In as much as out-of-band
  231. signalling is far more common than in-band class five types (cf. Japan, 
  232. Australlia, Europe) is urgent that North American phreaks inform themselves on
  233. this subject. Other than info about prosecutions, nothing has been received so
  234. far. We are continuing to monitor all legal developments in phreaking on a 
  235. regular basis. Ofcoarse black boxing should be easy even under an out-of-band
  236. system, but redirecting calls? And what codes would access overseas senders
  237. Re Con Ed: Happily I am far removed from them these days. Telling them that 
  238. you are a a new tenant often does'nt work without a lease to prove it. You 
  239. have to pretent to be the OLD tenant, and say you are moving. (Give an old 
  240. address). That gets you off the hook;they transfer your account, especially if
  241. they already have a deposit. After the account is cleared up on the computer
  242. (remember, they use microfilm for their records, and it's several days behind)
  243. you can open your new account.
  244.                          -CANADA-
  245.  
  246. Dear TAP,
  247. A year ago a friend and I were into faking the money dropping in old 3 slot 
  248. payphones by using an old payphone top, containing the bell and gong for coin
  249. sounds. Thru operator responses, visiting the switchboards, and looking at 
  250. coin collect  mechanisms, I discovered that when handling a payphone call, a 
  251. read light is lit on the operator's switchboard until the 1st coin drops.
  252. After that the light goes out and a green light goes on & stays on until money
  253. is collected or returned, when the green goes off & the red comes on again. 
  254. The lights don't indicate if the money was collected or returned, just if a 
  255. first coin was deposited, and whether the lever has returned to normal 
  256. position after collect or return.
  257.      On some operator boards, they have a BV key. One operator told me that 
  258. she  was only told it was for computer access to dial Rate & Route, such as BV
  259. 009 ST, then KP-AC-XXN-XXN-1-ST(first XXN is desired exchange, second is
  260. calling exchange) to get the computer-generated voice. But BV can also get
  261. local verification, which the fuckheads didn't tell our operators. Is there an
  262. MF tone to the BV key? What is it? Does anyone know how to use the 700 + 1700 
  263. coin collect and 1100 + 1700 coin return tones?
  264.                              -KANSAS-
  265.  
  266.    YOU CAN HELP TAP
  267.  
  268.        If you contribute any information that you thin other readers would be 
  269. interested in, please do so. TAP readers are the main source of our informa-
  270. tion. You can help by meeting employees of phone and power companies, alarm
  271. places, etc., and asking them about questions other people raise in the news-
  272. letter. Be sure to get details and maintain contact in case you have addition-
  273. al questions. Most employee's of those companies would be glad to screw their
  274. boss and they'd probably be interested in TAP, too. We hope that alot of you
  275. will gather information so we know what the scene is around the country and
  276. Canada.
  277.  
  278. TAP, Room 504, 152 W 42 st. N.Y.,N.Y. 10036
  279. Mailing address only
  280.  
  281. Dear TAP
  282. Thought I'd write and tell the rest of phreakdom about a technique for tapping
  283. neighbor's phone lines that I used to use, for whatever it's worth. The
  284. problem with a direct tap is that sooner or later some phone company type is
  285. going to come and check the line. To make it indetectable:
  286.      We are going to use the two spare wires of the 4-wire cable to your phone
  287. (usually yellow & black). First locate your cable and the tappee's cable in
  288. the main box for your apartment. (A phone with clip leads will help). Then
  289. trip the length  and stip the ends of the two wires. They should be just long
  290. enough to reach the terminals of the other with NO slack. The wires should
  291. then be attached to the terminals just loose enough so that they pull off
  292. easily. Straighten and strip some of the other cables' yellow and black wires 
  293. too so that your's won't look different later. Then run a big wire (12 gauge
  294. house wire is fine) under your wires. Close the box lid as tight as possible
  295. and twist the wire ends together. Now when the box is opened the wires will be
  296. ripped loose. The Phoneperson will not cut the outside wire before opening it
  297. up because the whole thing might fall. With a DPDT toggle switch (and line
  298. relays, recorders, etc.) you may now freely use the line. A BB will be safe and
  299. cause no charge to the other party's line-Ed.
  300.       I built the Red Box from your last issue and like it. The two diodes 
  301. feeding the 500K pots for 5 cents and 10 cents aren't needed. I am also doing 
  302. research on bank machines and "money cards". If I can crack their code on the 
  303. cards and rewrite them it could be good for $1000 a day. I will appreciate any
  304. help on this (bank employees could really help).
  305.                            -Indiana-
  306.  
  307. Dear TAP,
  308. "The best things in life are free, almost..." according to the Theta Cable TV
  309. ads in Los Angeles. On April 26 Theta introduced the 'Z channel'. You can watch first run movies for $6.95 per month for the first TV and $1.95 for each
  310. additional TV, right? Wrong! Because if you want to watch the Z channel all you
  311. have to do is press '2' and the '8' buttons on the channel selector at the same
  312. time. So don't forget, 2 + 8 = Z. And it's free!
  313.                             -Theata, The goddess of TV
  314.  
  315. Dear TAP,
  316. Alabama Power has increased my line voltage from 115 to 130 volts. They won't
  317. lower the voltage(they claim its impossible) and I have blown the flyback
  318. transformers on 2 TV sets. This voltage increase has also increased my electric
  319. bill by 27% more I'd like to cheat back. Here is the formula for computing your
  320. own power company's ripoff on you:
  321. Power=Voltage X Current so if the voltage is upped the increase in power is:
  322.  
  323. Power increase = (New Voltage)^2 - (Old voltage)^2
  324.                  ---------------------------------
  325.                            (Old Voltage)^2
  326.  
  327. Multiply this by 100 to get the percentage increase.
  328.  
  329.      So, All an electric company has to do for an Instant rate increase is step
  330. up the line voltage. My electric company has done this to me without regard for
  331. my appliances or my pocketbook. Any back issues that you have to help me outfox
  332. their meters will allow me to strike back.
  333.                           -Alabama-
  334.  
  335.  
  336. Published for informational purposes only by Youth Hot Line Reports, Inc.
  337.  
  338.  
  339.