home *** CD-ROM | disk | FTP | other *** search
/ TAP YIPL / TAP_and_YIPL_Collection_CD.iso / PHREAK / CELLULAR / RADIOS~7.TXT < prev    next >
Encoding:
Text File  |  2000-01-02  |  3.8 KB  |  83 lines

  1. Programing Tandy CT-301 Cellular Telephone
  2.                 By RECON
  3.  
  4. Caution:  This procedure is intended for use by Radio Shack Store
  5. personnel only.  Do not give this information to a customer or any
  6. other outside person.
  7.  
  8. You can program the NAM parameters into the CT-301 using the phone's
  9. keypad.  The following chart shows the parameters in the order they
  10. apper on the display during programming.  The chart also provides the
  11. parameter abreviations used on the display, the number of digits for
  12. each parameter, the possible ranges of each parameter.
  13.  
  14. The security code is set to 12345 at the factory.  You are given the
  15. option to change the lock code at the end of this procedure.
  16.  
  17. The parameters listed in the YOUR PARAMETER collum are the parameters
  18. for the Boise, ID area.
  19. ______________________________________________________________________
  20. NAM            :Displayed   :Number:           :Your
  21. Parameter      :Abbreviation:Digits:   Range   :Parameter
  22. ---------------:------------:------:-----------:----------------------
  23. Home System ID :HO-ld       :  5   :00000-32767:00272
  24. ---------------:------------:------:-----------:----------------------
  25. Access Method  :ACCESS      :  1   :0-1        :1
  26. ---------------:------------:------:-----------:----------------------
  27. Local Control  :LOCAL       :  1   :0-1        :1
  28. Option         :            :      :           :
  29. ---------------:------------:------:-----------:----------------------
  30. Phone Number   :PhonE n     : 10   :0000000000-:
  31.                :            :      :9999999999 :
  32. ---------------:------------:------:-----------:----------------------
  33. Station Class  :CLASS       :  2   :00-99      :10
  34. Mark           :            :      :           :
  35. ---------------:------------:------:-----------:----------------------
  36. Home Paging    :PAGE ch     :  3   :001-666    :334
  37. Control        :            :      :           :
  38. ---------------:------------:------:-----------:----------------------
  39. Overload Class :O-LOAd      :  2   :00-15      :15
  40. ---------------:------------:------:-----------:----------------------
  41. Group ID       :GrouP       :  2   :00-15      :15
  42. ---------------:------------:------:-----------:----------------------
  43. Security Code  :Sec CodE    :  5   :00000-99999:
  44. ----------------------------------------------------------------------
  45.  
  46. To program the phone:
  47.  
  48. 1. Enter
  49.          [*] 17 [*] 2001 [*] secrity code [*]
  50. The first parameter cattegory [HO-ld; for home system identification]
  51. appears on the display.
  52.  
  53. 2. Press [SEL] to display the current value for the parameter.
  54.  
  55. 3. While the current value is displayed, enter the correct number on
  56. the phone keypad.  If the parameter is already correct, proceed
  57. dirctly to the next step.  If you have problems, see "Programming
  58. Hints."
  59.  
  60. 4. Press [SEL] to display the name of the next parameter category.
  61.  
  62. 5. Repeat Steps 2-4 to program each of the parameters.
  63.  
  64.    When you press [SEL] the last time (after entering the customer's
  65. 5-digit security code), the parameter information is stored and the
  66. phone returns to the normal power-on mode.
  67.  
  68. 6. Although the CT-301 automatically selects the preferred system, you
  69. still have to set the system priority to A or B, as described in the
  70. CT-301's owener's manual.
  71.  
  72. Programming Hints:
  73. * If you try to enter a parameter that is out of the listed range or
  74. that has fewer than the listed number of digits, a beep sounds.
  75. Repeatedly press [CLR] until the display is clear, and enter the
  76. correct value.
  77.  
  78. * To check the entered information, re-enter the programming mode and
  79. repeatedly press [SEL].
  80.  
  81. * You can terminate programming at any time by pressing [SEL] [END].  New parameters entered to that point are stored in memory.
  82. ---------------------------------------------------------------------
  83.