*3001#12345# to enter field test mode and NAM selection
*#9999# shows the software version
GSM Model: 5190
*#5190# shows the software version
*3001#12345# to enter NAM programming mode: For Fido phones, Home System ID is 16420; Own number is your phone number (10 digits); Change defaults includes the primary paging channel (e.g. 334), Overload Class (10), and Group ID (10). Turn off the handset to get out of this menu.
*#92772689# shows service menu. There are 6 sub-menus including: 1. ESN; 2. Manufacture date; 3. Programming Date; 4. Repair Date; 5. Transfer user data; and 6. Life Timer.
This model requires a data cable to access test mode information
GSM Model: 6190
*#6190# shows the software version
*#92772689# (after removing the analog module on 5190) shows service menu. There are 6 sub-menus including: 1. ESN; 2. Manufacture date; 3. Programming Date; 4. Repair Date; 5. Transfer user data; and 6. Life Timer.
*3001#12345[OK] to enter AMPS NAM programming mode
This model requires a data cable to access test mode information
CDMA Models: 6185/6188
See the Nokia 6185/6188 test mode page.
Test Mode Information
The test mode display is activated through the NAM programming procedure. Once you enter *3001#12345# you must power down the phone and power it up again. To get out of test mode re-enter *3001#12345# and power down the phone.
Once you power up the phone you are given a new menu choice of FIELD TEST. There are a total of 7 different test mode screens and they may vary somewhat between the different Nokia models, select any number between 1-7 or hit 0 to exit. Use the arrow buttons to move between field test screens.
Screen 1
Digital control channel
rssi DVC S
Bchan Pw A
CS-state
Digital traffic channel
rssi s d
Bchan l a
CS-state
Analog control channel
rssi D d
Bchan Pw A
CS-state
Analog traffic channel
rssi DVC S
Bchan l a
CS-state
rssi Received Signal Strength Indicator (-113 to -51 dBm, increments in steps of 2 dB)
DVC Digital Verification Colour Code (1-255 or - for not locked)
D Digital Verification Colour Code in analog control channel (0-3 or - for not locked)
s SAT Colour (0-2 or - for not locked)
d Data Receiving Status (0 = no data, 1 = unable to read, 2 = read and correct, 3 = read and not correct)
S Time slot (1-3)
B Network Band and Frequency (lowercase a,b = 800 MHz band; uppercase A,B = 1900 MHz band)
chan Channel (0001-1023)
BER Bit Error Ratio (only on some models -- not shown on these example screens)
Pw Maximum Access Power (DCCH: 0-10 or - for not locked; ACCH: 0-7 or - for not locked)
l Transmit level (0-10 or - for OFF)
A Unknown??
a Audio State (0 = OFF or 1 = ON)
CS-state Indication of Cellular State as follows:
DCCH: SCAN-LOCK - Scanning and locking of Digital Control Channel
DCCH: DCCH-SEL - DCCH selectionb
DCCH: CAMPING - Channel camping
DCCH: REGISTR - Registration
DCCH: WAIT-ORDER - Waiting for order
DCCH: ORIGINAT - Origination proceeding
DCCH: RESELECT - Reselection
DCCH: ORIG-SMS - Origination SMS proceeding
DCCH: TERM-SMS - Termination of SMS
DTCH: TCH - Confirming traffic channel
XTCH: CONVERSAT - Conversation
ACCH: OOR - Out Of Range
ACCH: SCAN-PDCH - Scan primary dedicated control channels
ACCH: SCAN-SDCH - Scan secondary dedicated control channels
ACCH: SCAN-PCH - Scan paging channels
ACCH: IDLE - Idle
ACCH: ACCESS - Access
ACCH: VCH - Confirm Voice Channel
Screen 2
Digital control channel
mode M C
FB E SP pc
net SID
Digital traffic channel
mode DTX
ENCR CIPH
d Be TA
Analog control channel
mode
XSTBY
SID
Analog traffic channel
mode
SAT
mode One of: DCCH, DTCH, ACCH, or AVCH
SID System Identification Number 0-32767 (odd for A-band carriers [e.g., Cantel, AT&T], even for B-band carriers [e.g., Mobility, Airtouch]])
DCCH:
M - Maximum paging frame class supported by network (1-8)
C - Current paging frame class
FB - Number of F-BCCH slots
E - Number of E-BCCH slots
SP - Number of SPACH slots
pc - PCH subchannel
net - Supported network types (0 = not supported, 1 = supported)
DTCH:
DTX - Unknown
ENCR - Shown when message encryption is active
CIPH - Shown when voice ciphering is active
d - Data receiving status (0 = not active, 1 = active)
Be - Bit Error Ratio (0-16)
TA - Current time alignment (0-30)
ACCH:
XSTBY - Shown when extended standby is active
AVCH:
SAT - SAT validity (0-32767)
Screen 3
RS SS SI b
NA ND
MA MD MO
RS Minimum Received Signal Strength required to access cell (0 to 31)
SS Minimum Signal Strength for reselection
SI Scan Interval between consecutive strength measurements in hyperframes (0 to 16)
b Access burst sieze (0 for normal, 1 for abbreviated RACH)
NA Number of analog neighbours (0 to 24)
ND Number of digital neighbours (0 to 24)
MA ???
MD ???
MO ???
Screen 4
SID #####
NN NT NR
Alphatag
SID System Identification Number (0 to 32767, odd for 'A' carriers, even for 'B' carriers)
NN ???
NT ???
NR ???
Alphatag User display
Screen 5
S bandorde
NC NP IRC
RSCO RSLO
bandorde Network search order: (a - 800 MHz A-band, b - 800 MHz B-band, A - 1900 MHz A-band, B- 1900 MHz B-band)