GENERAL ELECTRIC MINI II
NOTES: This is a dual NAM portable unit.
The ESN prefix is 134 decimal, 86 hex (Mitsubishi)
See file MITSTEST.TXT for test mode information.
General Electric: 1-800-528-7711
NAM PROGRAMING:
1. Press PWR key for one second to turn power on.
2. Wait for wake up cycle to finish & display to clear.
3. Within ten seconds press and hold the END key while entering
6 2 8 2 9 0 5.
4. Press SEND to store data and increment the step number.
5. Press END to complete programing and exit at any time.
PROGRAMING DATA:
STEP# #OF DIGITS/RANGE DISPLAY DESCRIPTION
01 0 OR 1 DUAL NO DUAL NAM
02 10 DIGITS NO1 MIN (AREA CODE & TEL#)
03 00000 - 32767 SID1 SYSTEM ID
04 0 OR 1 LU1 LOCAL USE MARK
05 0 OR 1 EX1 EXTENDED ADDRESS MARK
06 0333 OR 0334 IPCH1 INITIAL PAGING CHANNEL
07 2 DIGITS ACCOLC1 ACCESS OVERLOAD CLASS
08 0 OR 1 PREF1 PREFERRED SYSTEM (0=B,1=A)
09 2 DIGITS GIM1 GROUP ID (10 IN USA)
10 0 OR 1 RI1 ROAM INHIBIT
11 0 OR 1 DTX1 VOX MODE
12 0 OR 1 AR1 SYSTEM AUTO REDIAL
If you entered "0" in step 01 go to step 24
2ND NAM DATA:
13 10 DIGITS NO2 MIN (AREA CODE & TEL#)
14 00000 - 32767 SID2 SYSTEM ID
15 0 OR 1 LU2 LOCAL USE MARK
16 0 OR 1 EX2 EXTENDED ADDRESS MARK
17 0333 OR 0334 IPCH2 INITIAL PAGING CHANNEL
18 2 DIGITS ACCOLC2 ACCESS OVERLOAD CLASS
19 0 OR 1 PREF2 PREFERRED SYSTEM (0=B, 1=A)
20 2 DIGITS GIM2 GROUP ID (10 IN USA)
21 0 OR 1 RI2 ROAM INHIBIT
22 0 OR 1 DTX2 VOX MODE
23 0 OR 1 AR2 SYSTEM AUTO REDIAL
24 4 DIGITS SEC SECURITY CODE
25 0 OR 1 EE END TO END (DTMF) DIALING
26 0 OR 1 C TONE CONTINUOUS DTMF
27 0 OR 1 AL AUTO LOCK
28 0 OR 1 BEEP CALL TIMER AUDIO BEEP
29 0 OR 1 BO 3 WATT BOOSTER OPTION
NOTES:
Install lock code with phone out of programing mode, enter FCN 7 SSSS
LLL CLR, where SSSS is the security code and LLL is the new lock code.
LOCK: F 2. UNLOCK: Enter three digit code, press SEND.
SYSTEM SELECT: F 1 displays current then press one of the following to change:
0 = Pref/non pref, 1 = Non pref/pref, 2 = Home only, 3 = Pref only, 4 = Non
pref only.